The Nutrifill preservative free insertion solution is indicated as an insertion solution for large diameter (scleral), hybrid and rigid gas permeable (RGP) contact lenses following proper lens care disinfection as recommended by the eye care practitioner. This solution may also be used for rinsing debris and lens cleaners from rigid gas permeable, hybrid and hard contact lenses, as a rinse for contact lens cases and may be used as needed throughout the day to rinse contact lenses.
Device Story
Nutrifill is a sterile, preservative-free, isotonic buffered solution containing electrolytes (calcium, magnesium, potassium, phosphate). Supplied in single-dose 10ml vials. Used by patients to rinse debris and cleaning solutions from rigid gas permeable (RGP), hard, and hybrid contact lenses prior to insertion. Also used to rinse lens cases and for periodic rinsing throughout the day. The solution is applied directly to the lens; it facilitates comfortable lens insertion and maintenance. It does not perform disinfection; it is used after the practitioner-recommended disinfection process. Benefits include removal of residual cleaning agents and debris, potentially improving comfort for scleral and RGP lens wearers.
Clinical Evidence
No clinical data. Bench testing only. Non-clinical studies demonstrated the solution and packaging are non-toxic and non-irritating.
Technological Characteristics
Sterile, isotonic, preservative-free aqueous solution. Contains electrolytes: calcium, magnesium, potassium, phosphate. Buffered with phosphate buffer to ocular pH and osmolarity. Form factor: 10 mL single-dose plastic resin vial with twist-off cap. No electronic or software components.
Indications for Use
Indicated for users of large diameter (scleral), hybrid, and rigid gas permeable (RGP) contact lenses. Used for lens insertion following disinfection, rinsing debris/cleaners from lenses, rinsing lens cases, and as needed for daily lens rinsing.
Regulatory Classification
Identification
A rigid gas permeable contact lens care product is a device intended for use in the cleaning, conditioning, rinsing, lubricating/rewetting, or storing of a rigid gas permeable contact lens. This includes all solutions and tablets used together with rigid gas permeable contact lenses.
Special Controls
*Classification.* Class II (Special Controls) Guidance Document: “Guidance for Industry Premarket Notification (510(k)) Guidance Document for Contact Lens Care Products.”
{0}------------------------------------------------
## 510 (k) SUMMARY OF SAFETY AND EFFECTIVENESS
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92.
The assigned 510(k) number is: K181566
#### I. SUBMITTER
- Sept 18th 2018 Date Prepared:
- Name: Contamac Ltd. Address: Carlton House Shire Hill Saffron Walden Essex CB11 3AU Contact Person: Robert McGregor Managing Director Phone number: 01799 514800 Consultant: Bret Andre EyeReg Consulting, Inc. 6119 Canter Ln. West Linn, OR 97068 Phone number: (503) 372-5226
#### II. DEVICE
| Trade Name: | Nutrifill |
|-------------------------|------------------------------------------------------------------|
| Common<br>Name: | Contact Lens Insertion Solution |
| Classification<br>Name: | Rigid Gas Permeable Contact Lens Care Products (21 CFR 886.5918) |
| Regulatory<br>Class: | Class II |
| Product Code: | MRC |
{1}------------------------------------------------
#### III. PREDICATE DEVICE
The Nutrifill preservative free insertion solution is substantially equivalent in terms of actions and indications to the following predicate device(s):
- . "LensGiene™ Sterile Saline Solution (Alternate Trade Name: ScleralFil)" By Bausch + Lomb, Inc. 510(k) number: K161622 Device Classification: II
- . "Menicon Saline Rinse Solution" By Menicon Co., Ltd. 510(k) number: K151768 Device Classification: II
#### DEVICE DESCRIPTION IV.
The Nutrifill preservative free insertion solution is a sterile isotonic buffered solution containing electrolytes (calcium, magnesium, phosphate, sodium) in a single dose, carry-on size 10ml vial. It rinses loose debris and cleaning solution off rigid gas permeable (RGP), hard and hybrid contact lenses prior to insertion. The sterile solution can be used to rinse contact lens cases and contact lenses as needed throughout the day.
#### V. INDICATIONS FOR USE
The Nutrifill preservative free insertion solution is indicated as an insertion solution for large diameter (scleral), hybrid and rigid gas permeable (RGP) contact lenses following proper lens care disinfection as recommended by the eye care practitioner. This solution may also be used for rinsing debris and lens cleaners from rigid gas permeable, hybrid and hard contact lenses, as a rinse for contact lens cases and may be used as needed throughout the day to rinse contact lenses.
#### VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH PREDICATE DEVICE
The Nutrifill preservative free insertion solution is substantially equivalent to the predicate devices in terms of the following:
- 트 Intended use
- 트 Indications for use
- Actions
- I Classification - Rigid Gas Permeable Contact Lens Care Products (21 CFR 886.5918)
- 트 How supplied (sterile, single dose)
- Preservative free formulation
The Nutrifill preservative free insertion solution is unique from the predicate device in terms of the
{2}------------------------------------------------
following:
- י Nutrifill contains additional electrolytes (calcium, magnesium, potassium, phosphate)
- י Nutrifill is buffered with a phosphate buffer at normal ocular pH and osmolarity
The following matrix illustrates the intended use and other characteristics of the Nutrifill preservative free insertion solution, as well as the predicate device.
| | Contamac, Ltd.<br>Nutrifill | Bausch + Lomb, Inc.<br>LensGiene™ Sterile Saline<br>Solution (ScleralFil) | Menicon Co., Ltd.<br>Menicon Saline Rinse<br>Solution |
|------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| | New Device | Predicate Device (K161622) | Predicate Device (K151768) |
| Intended Use | The Nutrifill preservative free<br>insertion solution is indicated<br>as an insertion solution for<br>large diameter (scleral) and<br>hybrid contact lenses following<br>proper lens care disinfection as<br>recommended by the eye care<br>practitioner. This solution may<br>also be used for rinsing debris<br>and lens cleaners from rigid gas<br>permeable, hybrid and hard<br>contact lenses, as a rinse for<br>contact lens cases and may be<br>used as needed throughout the<br>day to rinse contact lenses. | The LensGiene™ Sterile Saline<br>Solution is indicated for use<br>following proper lens disinfection<br>as recommended by the eye care<br>practitioner. The LensGiene™<br>Sterile Saline Solution is for<br>rinsing soft (hydrophilic), rigid<br>gas permeable and hard contact<br>lenses prior to lens insertion. This<br>solution may also be used as an<br>insertion solution for large<br>diameter (scleral) contact lenses,<br>as a rinse for contact lens cases,<br>and may be used as needed<br>throughout the day to rinse<br>contact lenses. | For use following proper<br>lens disinfection as<br>recommended by the eye<br>care practitioner. The<br>Menicon Saline Rinse<br>Solution is for rinsing soft<br>(hydrophilic), rigid gas<br>permeable and hard contact<br>lenses prior to lens insertion.<br>This solution may also be<br>used as an insertion solution<br>for large diameter (scleral)<br>contact lenses, as a rinse for<br>contact lens cases, and may<br>be used as needed<br>throughout the day to rinse<br>contact lenses. |
| Classification | 21 CFR 886.5918 | 21 CFR 886.5918 ; 21 CFR<br>886.5928 | 21 CFR 886.5918 ; 21 CFR<br>886.5928 |
| Product Code | MRC | MRC; LPN | MRC; LPN |
| Class | Class II | Class II | Class II |
| Volume | 10 mL per dose | 10 mL per dose | 5 mL per dose |
| Preservative Free | Yes | Yes | Yes |
| Single or Multi Dose | Single Dose | Single Dose | Single Dose |
| Sterility | Sterile | Sterile | Sterile |
| Container | Plastic resin container with<br>twist off cap | Plastic resin container with twist<br>off cap | Plastic resin container with<br>twist off cap |
| Contains Electrolytes<br>(Calcium, Magnesium,<br>Potassium, Phosphate) | Yes | No | No |
{3}------------------------------------------------
#### VII. PERFORMANCE DATA
### ~ Non-Clinical Studies ~
A series of studies were completed to demonstrate the substantial equivalence of the Nutrifill preservative free insertion solution to the predicate device. Results of non-clinical testing demonstrate:
- The Nutrifill solution is non-toxic and non-irritating
- The final packaging is non-toxic and non-irritating ●
## ~ Clinical Studies ~
Clinical studies involving the Nutrifill solution were unnecessary for this application. Lens care solutions used with this Nutrifill solution are already cleared for use as cleaning, rinsing, disinfection and storage solutions for contact lenses.
## VIII. CONCLUSIONS
## Substantial Equivalence
Based on the composition of the solution and results of non-clinical testing presented in this Premarket Notification, the Nutrifill preservative free insertion solution is as safe and effective as the predicate device when used in accordance with the labeled directions for use and for the proposed indication.
{4}------------------------------------------------
# Please wait...
If this message is not eventually replaced by the proper contents of the document, your PDF viewer may not be able to display this type of document.
You can upgrade to the latest version of Adobe Reader for Windows®, Mac, or Linux® by visiting http://www.adobe.com/go/reader_download.
For more assistance with Adobe Reader visit http://www.adobe.com/go/acrreader.
Windows is either a registered trademark of Microsoft Corporation in the United States and/or other countries. Mac is a trademark of Apple Inc., registered in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA acronym followed by the full name of the agency on the right. The FDA part of the logo is in blue, with the acronym in a solid blue square and the words "U.S. FOOD & DRUG ADMINISTRATION" in a lighter blue.
October 22, 2018
1
Contamac Ltd. % Bret Andre Principal Consultant EyeReg Consulting, Inc. 6119 Canter Ln West Linn. OR 97068
Re: K181566
Trade/Device Name: Nutrifill Regulation Number: 21 CFR 886.5918 Regulation Name: Rigid Gas Permeable Contact Lens Care Products Regulatory Class: Class II Product Code: MRC Dated: September 18, 2018 Received: September 21, 2018
Dear Bret Andre:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{6}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801): medical device reporting (reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/CombinationProducts/GuidanceRegulatoryInformation/ucm597488.html; good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
for Malvina B. Eydelman, M.D. Director Division of Ophthalmic and Ear. Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.