SUSTAIN® R Spacers, PATRIOT® Spacers, CALIBER® Spacers, RISE® Spacers, COALITION® Spacers, COALITION AGX™ Spacers, INDEPENDENCE® Spacers, FORTIFY®-R Corpectomy Spacers, FORTIFY® I-R Corpectomy Spacers, XPand®-R Corpectomy Spacers, NIKO® Corpectomy Spacers, MONUMENT™ Spacers, ALTERA™ Spacers, MAGNIFY™ Spacers, InterContinental® Plate-Spacer

K152022 · Globus Medical, Inc. · MAX · Feb 22, 2017 · Orthopedic

Device Facts

Record IDK152022
Device NameSUSTAIN® R Spacers, PATRIOT® Spacers, CALIBER® Spacers, RISE® Spacers, COALITION® Spacers, COALITION AGX™ Spacers, INDEPENDENCE® Spacers, FORTIFY®-R Corpectomy Spacers, FORTIFY® I-R Corpectomy Spacers, XPand®-R Corpectomy Spacers, NIKO® Corpectomy Spacers, MONUMENT™ Spacers, ALTERA™ Spacers, MAGNIFY™ Spacers, InterContinental® Plate-Spacer
ApplicantGlobus Medical, Inc.
Product CodeMAX · Orthopedic
Decision DateFeb 22, 2017
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3080
Device ClassClass 2
AttributesTherapeutic

Indications for Use

When used as lumbar intervertebral body fusion devices, SUSTAIN® and SUSTAIN® Radiolucent (SUSTAIN® R) Spacers are intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The SUSTAIN® and SUSTAIN® R Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the REVERE®, REVOLVE® or BEACON® Stabilization Systems. When used as cervical intervertebral body fusion devices, the SUSTAIN® and SUSTAIN® R Spacers are intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C2-T1) at one level. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of non-operative treatment. The SUSTAIN® and SUSTAIN® R Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the ASSURE®, PROVIDENCE® or XTEND® Anterior Cervical Plate Systems. When used as vertebral body replacement devices, SUSTAIN® and SUSTAIN® R Spacers are intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged or unstable vertebral body due to tumor or trauma (i.e., fracture). The spacers are intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, anterior plate systems and anterior screw and rod systems). The interior of the spacer can be packed with bone grafting material. SUSTAIN® and SUSTAIN® R Spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period.

Device Story

Spinal spacers provide structural stability following discectomy, corpectomy, or vertebrectomy; used as intervertebral body fusion or vertebral body replacement devices. Inputs: surgical site anatomy; bone graft material packed into axial holes. Operation: spacers inserted via various approaches (anterior, posterior, lateral, etc.); protrusions on superior/inferior surfaces grip endplates to resist expulsion; some models expandable or include integrated plates/screws for fixation. Output: stabilized spinal column segment. Used in OR by surgeons. Benefits: anterior spinal column support; facilitates fusion; restores stability in damaged/unstable vertebrae.

Clinical Evidence

Bench testing only. Mechanical performance assessed per ASTM F2077 comparing subject and predicate systems.

Technological Characteristics

Materials: PEEK (ASTM F2026), titanium alloy (ASTM F136, F1295, F1472), tantalum (ASTM F560), cobalt chromium molybdenum (ASTM F1537), commercially pure titanium (ASTM F67). Features: plasma spray coating (ASTM F1580), hydroxyapatite coating (ASTM F1185). Form factor: various shapes/heights for spinal approaches. Energy: none (mechanical).

Indications for Use

Indicated for skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1) or one level of the cervical spine (C2-T1), or for vertebral body replacement in the thoracolumbar spine (T1-L5) due to tumor or trauma. Patients with DDD must have discogenic pain confirmed by history/radiography and failed 6 months (lumbar) or 6 weeks (cervical) of non-operative treatment. Lumbar patients may have up to Grade 1 spondylolisthesis or retrolisthesis.

Regulatory Classification

Identification

An intervertebral body fusion device is an implanted single or multiple component spinal device made from a variety of materials, including titanium and polymers. The device is inserted into the intervertebral body space of the cervical or lumbosacral spine, and is intended for intervertebral body fusion.

Special Controls

*Classification.* (1) Class II (special controls) for intervertebral body fusion devices that contain bone grafting material. The special control is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intervertebral Body Fusion Device.” See § 888.1(e) for the availability of this guidance document.(2) Class III (premarket approval) for intervertebral body fusion devices that include any therapeutic biologic (e.g., bone morphogenic protein). Intervertebral body fusion devices that contain any therapeutic biologic require premarket approval. (c) *Date premarket approval application (PMA) or notice of product development protocol (PDP) is required.* Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized symbol of three human profiles facing to the right, stacked on top of each other. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 February 22, 2017 Globus Medical, Inc. Kelly J. Baker, Ph.D. Senior Vice President, Regulatory and Clinical Affairs Valley Forge Business Center 2560 General Armistead Avenue Audubon, Pennsylvania 19403 Re: K152022 Trade/Device Name: SUSTAIN® R Spacers, PATRIOT® Spacers, CALIBER® Spacers, RISE® Spacers, COALITION® Spacers, COALITION AGXTM Spacers, INDEPENDENCE® Spacers, FORTIFY®-R Corpectomy Spacers, FORTIFY® I-R Corpectomy Spacers, XPand®-R Corpectomy Spacers, NIKO® Corpectomy Spacers, MONUMENTTM Spacers, ALTERATM Spacers, MAGNIFYTM Spacers, InterContinental® Plate-Spacer Regulation Number: 21 CFR 888.3080 Regulation Name: Intervertebral body fusion device Regulatory Class: Class II Product Code: MAX, MQP, ODP, OVE, OVD Dated: February 8, 2017 Received: February 10, 2017 Dear Dr. Baker: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # Mark N. Melkerson -S Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indications for Use 510(k) Number (if known) K152022 #### Device Name SUSTAIN® R Spacers, PATRIOT® Spacers, CALIBER® Spacers, COALITION® Spacers, COALITION® Spacers, COALITION AGX™ Spacers, INDEPENDE® Spacers, FORTIFY@-R Corpectomy Spacers, FORTIFY® I-R Corpectomy Spacers, XPand®-R Corpectorny Spacers, NIKO® Corpectony Spacers, MONUMENT™ Spacers, MAGNIFY™ Spacers, InterContinental® Plate-Spaces #### Indications for Use (Describe) #### SUSTAIN® R Spacers When used as lumbar intervertebral body fusion devices, SUSTAIN® Radiolucent (SUSTAIN® R) Spacers are intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of nonoperative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis at the involved level(s). The SUSTAIN® and SUSTAIN® R Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the REVERE®, REVOLVE® or BEACON® Stabilization Systems. When used as cervical intervertebral body fusion devices, the SUSTAIN® R Spacers are intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C2-T1) at one level. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of non-operative treatment. The SUSTAIN® and SUSTAIN® R Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the ASSURE®, PROVIDENCE® or XTEND® Anterior Cervical Plate Systems. When used as vertebral body replacement devices, SUSTAIN® R Spacers are intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged or unstable vertebral body due to tumor or trauma (i.e., fracture). The spacers are intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems and anterior screw and rod systems). The interior of the spacer can be packed with bone grafting material. SUSTAIN® R Spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. #### PATRIOT® Spacers #### Lumbar Spacers PATRIOT® Spacers (including Constitution®, Constitution® TPS, Signature® TPS, Continental®, Continental® TPS, TransContinental®, TransContinental® TPS, TransContinental® M and TransContinental® M TPS) are interbody fusion devices intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc as confirmed by history and radiographic studies. These patients should be skeletally mature and at least six (0) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis at the involved level(s). PATRIOT® Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation systems that have been cleared for use in the lumbosacral spine (e.g. posterior pedicle screw and rod systems, anterior plate systems, and rod systems). Hyperlordotic interbody devices (≥20° lordosis) must be used with at least anterior supplemental fixation. #### Cervical Spacers PATRIOT® Spacers (COLONIAL® ACDF) are interbody fusion devices intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C3-T1) at one level. DDD is defined as discogence pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of nonoperative treatment. {3}------------------------------------------------ PATRIOT® Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the ASSURE® or PROVIDENCE® Anterior Cervical Plate System. #### CALIBER® Spacers CALIBER® Spacers are interbody fusion devices intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of nonoperative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). CALIBER® Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the REVERE® or REVOLVE® Stabilization Systems. #### RISE® Spacers The RISE® Spacer is a lumbar interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of nonoperative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The RISE® Spacer is to be filled with autogenous bone graft material. This device is intended to be used with supplemental fixation, such as the REVERE® or REVOLVE® Stabilization Systems. #### COALITION® and COALITION AGX™ Spacers The COALITION® and COALITION AGX™ Spacers are interbody fusion devices intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C2-T1) at one level. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and at least six (6) weeks of non-operative treatment. These devices are to be filled with autogenous bone graft material. The COALITION® Spacer is a stand-alone interbody fusion device. The COALITION AGX™ Spacer is intended to be used with supplemental fixation such as the COALITION AGX™ Plate, ASSURE®, PROVIDENCE™, VIP®, XTEND®, or UNIFY™ Anterior Cervical Plate Systems. When used with the COALITION AGX™ Plate, the assembly takes on the indications for use of the COALITION AGX™ Spacer, with the COALITION AGX™ Plate acting as the supplemental fixation. The COALITION AGX™ Plate is intended for anterior screw fixation to the cervical spine (C2-C7) for the following indications: degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumors, deformity (defined as kyphosis, lordosis, or scoliosis), pseudarthrosis, failed previous fusion, spondylolisthesis, and spinal stenosis, #### INDEPENDENCE® Spacers INDEPENDENCE® (including INDEPENDE® MIS, INDEPENDENCE® TPS, and INDEPENDENCE® MIS TPS) Spacers are interbody fusion devices intents with degenerative disc disc disc discase (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis at the involved level(s). INDEPENDENCE® Spacers are to be filled with autograft bone and/or allogenic bone graft composed of cancellous and/or corticocancellous bone. The INDEPENDENCE® Spacer is a stand-alone interbody fusion device intended to be used with three titanium alloy screws which accompany the implant. The INDEPENDENCE® MIS Spacer is an interbody fusion device to be used with three titanium alloy screws or anchors which accompany the implants. When used with screws. the INDEPENDENCE® MIS Spacer is a stand-alone interbody {4}------------------------------------------------ fusion device. When used with anchors, the INDEPENDENCE® MIS Spacer is intended for use with supplemental fixation (e.g. facet screws or posterior fixation). Hyperlordotic implants (≥25° lordosis) are intended for use with supplemental fixation (e.g. facet screws or posterior fixation). ### FORTIFY®-R and FORTIFY® I-R Corpectomy Spacers FORTIFY® (FORTIFY® and FORTIFY®-R) and FORTIFY® Integrated (FORTIFY® I and FORTIFY® I-R) Corpectomy Spacers are vertebral body replacement devices intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable vertebral body due to tumor or trauma (i.e., fracture). These devices are intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, and anterior screw and rod systems). The interior of the spacers can be packed with autogenous bone graft or allograft. These spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. #### XPand®-R Corpectomy Spacers The XPand® and XPand® Radiolucent Corpectomy Spacers are vertebral body replacement devices intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable vertebral body due to tumor or trauma (i.e., fracture). The XPand® and XPand® Radiolucent Corpectomy Spacers are intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, anterior plate systems, and rod systems). The interior of the spacer can be packed with bone grafting material. The XPand® and XPand® Radiolucent Corpectomy Spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. #### NIKO® Corpectomy Spacers The NIKO® Corpectomy Spacer is a vertebral body replacement device intended for use in the thoracolumbar spine (T1-LS) to replace a collapsed, damaged, or unstable vertebral body due to tumor or trauma (i.e., fracture). The NIKO® Corpectomy Spacer is intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, and anterior screw and rod systems). The interior of the spacer can be packed with bone grafting material. The NIKO® Corpectomy Spacer is designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. #### MONUMENT™ Spacers The MONUMENT™ Spacer is an interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of nonoperative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The MONUMENT™ Spacer is to be filled with autogenous bone graft material, and is to be used with four titanium alloy screws that accompany the implant. The device is intended to be used with supplemental fixation (i.e. pedicle screws, facet fixation). #### ALTERA™ Spacers The ALTERA™ Spacer is an interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of nonoperative treatment. In addition, these patients may have up to Grade 1spondylolisthesis or retrolisthesis at the involved level(s). The ALTERA™ Spacer is to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation. #### MAGNIFY™ Spacers The MAGNIFY™ Spacer is an interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of nonoperative treatment. In addition, these patients may have up to Grade 1 {5}------------------------------------------------ spondylolisthesis or retrolisthesis at the involved level(s). The MAGNIFY™ Spacer is to be filled with autogenous bone graft material, and is to be used with supplemental fixation, such as the CREO®, REVERE® or REVOLVE® Stabilization Systems. The MAGNIFY™-S Spacer is a stand-alone interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The MAGNIFY™-S Spacer is to be filled with autogenous bone graft material, and is to be used with three titanium alloy screws that accompany each implant. ## InterContinental® Plate-Spacers InterContinental® Plate-Spacers (including InterContinental® TPS) are lateral lumbar interbody fusion devices intended for use in patients with degenerative disc disease (DOD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DOD is defined as discogenic back pain with degeneration of the disc confirmed by history and radios. These patients should be skeletally mature and at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade I spondylolisthesis or retrolisthesis at the involved level(s). InterContinental® PlateSpacers are to be filled with autogenous bone graft material, and are to be used with two titanium alloy screws which accompany the implant. These devices are intended to be used with supplemental fixation (e.g. pedicle or facet screw systems) in addition to the integrated screws. Type of Use (Select one or both, as applicable) X Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {6}------------------------------------------------ ## 510(k) Summary: PEEK Devices | Company: | Globus Medical, Inc.<br>2560 General Armistead Ave.<br>Audubon, PA 19403<br>610-930-1800 | |-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Contact: | Kelly J. Baker, Ph.D.<br>Senior Vice President, Regulatory and Clinical Affairs | | Date Prepared: | February 20, 2017 | | Device Name: | SUSTAIN® R Spacers<br>PATRIOT® Spacers<br>CALIBER® Spacers<br>RISE® Spacers<br>COALITION® Spacers<br>COALITION AGX™ Spacers<br>INDEPENDENCE® Spacers<br>FORTIFY®-R Corpectomy Spacers<br>FORTIFY® I-R Corpectomy Spacers<br>XPand®-R Corpectomy Spacers<br>NIKO® Corpectomy Spacers<br>MONUMENT™ Spacers<br>ALTERA™ Spacers<br>MAGNIFY™ Spacers<br>InterContinental® Plate-Spacer | | Classification: | Per 21 CFR as follows:<br>§888.3060 Spinal Vertebral Body Replacement Device<br>and/or<br>§888.3080 Intervertebral Body Fusion Device<br>Product Code(s):<br>ODP SUSTAIN® R Spacers (Cervical)<br>PATRIOT® Spacers (Cervical)<br>COALITION AGX™ Spacers<br>MAX<br>SUSTAIN® R Spacers (Lumbar)<br>PATRIOT® Spacers (Lumbar)<br>CALIBER® Spacers<br>RISE® Spacers<br>ALTERA™ Spacers<br>MAGNIFY™ Spacers<br>InterContinental® Plate-Spacer<br>OVE COALITION® Spacers<br>COALITION AGX™ Spacers | {7}------------------------------------------------ - OVD INDEPENDENCE® Spacers MONUMENT™ Spacers MAGNIFY™-S Spacers InterContinental® Plate-Spacer - MQP FORTIFY®-R Corpectomy Spacers FORTIFY® I-R Corpectomy Spacers XPand®-R Corpectomy Spacers NIKO® Corpectomy Spacers SUSTAIN® R Spacers Regulatory Class: II, Panel Code: 87 Primary Predicate: SUSTAIN® R Spacers (K040284 & K130478) ## Additional | Predicate(s): | PATRIOT® Spacers (Cervical) (K072991) | |---------------|-----------------------------------------------| | | PATRIOT® Spacers (Lumbar) (K072970 & K122097) | | | PATRIOT® TransContinental® Spacer (K093242) | | | PATRIOT® TransContinental® M Spacer (K102313) | | | InterContinental® Plate-Spacer (K103382) | | | CALIBER® Spacers (K102293 & K123231) | | | COALITION® Spacers (K083389 & K131449) | | | COALITION AGX™ Spacers (K142218) | | | INDEPENDENCE® Spacers (K082252 & K120101) | | | MONUMENT ™ Spacers (K132559) | | | XPand®-R Corpectomy Spacers (K060665) | | | FORTIFY®-R Corpectomy Spacers (K112756) | | | FORTIFY® I-R Corpectomy Spacers (K121107) | | | NIKO® Corpectomy Spacers (K072465) | | | RISE® Spacers (K113447) | | | ALTERA™ Spacers (K140411) | | | MAGNIFY™ Spacers (K142498) | ## Purpose: The purpose of this submission is to request clearance for an additional PEEK vendor for the subject devices. ## Device Descriptions: ## SUSTAIN® Spacers SUSTAIN® and SUSTAIN® Radiolucent (SUSTAIN® R) Spacers are devices that can be used as intervertebral fusion devices or as vertebral body replacement devices. These spacers are available in different shapes and heights to accommodate various surgical approaches and anatomical needs. Protrusions on the superior and inferior surfaces of each device grip the {8}------------------------------------------------ endplates of the adjacent vertebrae to resist expulsion. Each spacer has an axial hole to allow grafting material to be packed inside the spacer. These spacers are used to provide structural stability in skeletally mature individuals following discectomy, corpectomy, or vertebrectomy (including partial). Lumbar spacers may be inserted using a posterior, transforaminal, anterior, anterolateral, or lateral lumbar approach. Cervical spacers are inserted using an anterior cervical approach. The SUSTAIN® Spacers are made from commercially pure titanium or titanium alloy as specified in ASTM F67, F136, and F1295.The SUSTAIN® R Spacers are made from radiolucent PEEK polymer with titanium alloy or tantalum markers as specified in ASTM F136, F560, F1295, and F2026. #### PATRIOT® Cervical Spacers PATRIOT® Spacers (COLONIAL® ACDF) are cervical interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. COLONIAL® ACDF Spacers are inserted through an anterior cervical approach, and are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. These spacers are to be filled with autogenous bone graft material. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to resist expulsion. PATRIOT® Spacers are made from radiolucent polymer, with titanium allov or tantalum markers, as specified in F2026, F136, F1295, and F560. ## PATRIOT® Lumbar Spacers PATRIOT® Spacers (including Constitution®, Constitution® TPS, Signature®, Signature® TPS, Continental®, Continental® TPS, TransContinental®, TransContinental® TPS, TransContinental® M and TransContinental® M TPS) are lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. Each of the PATRIOT® spacers provides a different shape to accommodate various surgical approaches to the lumbar spine. Constitution® PLIF Spacers are inserted using a posterior approach. Signature® TLIF Spacers are inserted using a transforaminal approach. Continental® ALIF Spacers are inserted using an anterior approach. Transcontinental® and TransContinental® M Spacers are inserted using an anterior or lateral approach. The devices are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. These spacers are to be filled with autogenous bone graft material. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to resist expulsion. PATRIOT® Spacers are made from PEEK radiolucent polymer (ASTM F2026) with titanium alloy or tantalum markers (ASTM F560). Signature® R Spacers {9}------------------------------------------------ also include an internal titanium alloy or commercially pure titanium (ASTM F67) component, and TransContinental® M Spacers also include an integrated titanium alloy nut. The Signature® Ti Spacer is made from titanium alloy or commercially pure titanium. The titanium alloy is TAV (ASTM F136) or TAN (ASTM F1295). PATRIOT® TPS Spacers also have a commercially pure titanium plasma spray coating, as specified in ASTM F67 and F1580. ## InterContinental® Plate-Spacer InterContinental® Plate-Spacers (including InterContinental® TPS) are lateral lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. InterContinental® Plate-Spacers are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. Protrusions on the superior and inferior surfaces grip the endplates of the adjacent vertebrae to aid in expulsion resistance. InterContinental® Plate-Spacers are to be filled with autogenous bone graft material, and are to be used with titanium alloy bone screws, with or without hydroxyapatite coating. Bone screws are used to attach to the lateral portion of the adjacent vertebral bodies for bony fixation. The spacers in the InterContinental® Plate-Spacers are manufactured from radiolucent polymer, with titanium alloy or tantalum markers, as specified in ASTM F136, F560, F1295, and F2026. The plates in the InterContinental® Plate-Spacers are manufactured from titanium alloy, as specified in ASTM F136 and F1295. The screws in the InterContinental® Plate-Spacers are manufactured from titanium alloy, as specified in ASTM F136 and F1295, and are available with or without hydroxyapatite (HA) coating, as specified in ASTM F1185. InterContinental® TPS Plate-Spacers also have a commercially pure titanium plasma spray coatinq, as specified in ASTM F67 and F1580. #### CALIBER® Spacers CALIBER® Spacers are lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. CALIBER® Spacers provide different shapes to accommodate various surgical approaches to the lumbar spine (posterior, transforaminal [posterolateral] or lateral). The devices are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. These spacers are to be filled with autogenous bone graft material. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to resist expulsion. CALIBER® Spacers are manufactured from radiolucent PEEK polymer and titanium alloy per ASTM F2026, F136 and F1295; non-expandable CALIBER® Spacers are manufactured from PEEK only. CALIBER® Spacers contain radiopaque titanium alloy or tantalum markers as specified in ASTM F136, F1295 and F560. {10}------------------------------------------------ ### COALITION® Spacers The COALITION® and COALITION AGX™ Spacers are a cervical interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. These spacers are inserted through an anterior cervical approach, and are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to aid in expulsion resistance. The spacer is to be filled with autogenous bone graft material. The COALITION AGX™ Plate is an anterior cervical fixation device that is available in various lengths and widths to fit the anatomical needs of a wide variety of patients. The COALITION® Spacer and the COALITION AGX™ Spacer used with a COALITION AGX™ Plate are stand-alone cervical interbody fusion devices. Screws are inserted through the anterior titanium portion of the implant into adjacent vertebral bodies for bony fixation. The COALITION® and COALITION AGX™ Spacers are manufactured radiolucent PEEK polymer, with titanium alloy or tantalum markers, as specified in ASTM F2026 F136, F1295 and F560. The plates are made from titanium alloy, as specified in ASTM, F136, F1295, and F1472. The screws are manufactured from titanium alloy, as specified in ASTM F136 and F1295. #### INDEPENDENCE® Spacers INDEPENDENCE® (including INDEPENDENCE® MIS, INDEPENDENCE® TPS, and INDEPENDENCE® MIS TPS) Spacers are anterior lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. The spacers are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to aid in expulsion resistance. Screws are inserted through the anterior titanium portion of the implant into adjacent vertebral bodies for bony fixation. The INDEPENDENCE® MIS Spacer may also be used with anchors inserted through the anterior titanium portion of the implants into adjacent vertebral bodies for bony fixation. INDEPENDENCE® and INDEPENDENCE® MIS Spacers are made from titanium alloy and radiolucent polymer with titanium alloy or tantalum markers, as specified in ASTM F136, F560, F1295, and F2026. INDEPENDENCE® MIS Spacers are additionally available in an all titanium alloy version. All PEEK implants are additionally available with a commercially pure titanium plasma spray coating (TPS), as specified in ASTM F1580 and F67. The screws and anchors are manufactured from titanium alloy, as specified in ASTM F136 and F1295, and the screws and anchors are available with or without hydroxyapatite (HA) coating, as specified in ASTM F1185. ## MONUMENT™ Spacers {11}------------------------------------------------ The MONUMENT™ Spacer is an anterior lumbar interbody fusion device used to provide structural stability in skeletally mature individuals following discectomy. The MONUMENT™ Spacer is intended to aid in reduction of a Grade 1 spondylolisthesis. The spacers are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to aid in expulsion resistance. Screws are inserted through the anterior titanium portion of the implant into adjacent vertebral bodies for bony fixation. The spacer is to be filled with autogenous bone graft material. The MONUMENT™ Spacer is made from PEEK radiolucent polymer and titanium alloy, as specified in ASTM F136, F1295, and F2026. The mating screws are manufactured from titanium alloy, as specified in ASTM F136 and F1295, and are available with hydroxyapatite (HA) coating, as specified in ASTM F1185. #### XPand® Corpectomy Spacers The XPand® and XPand® Radiolucent Corpectomy Spacer devices are vertebral body replacement devices used to provide structural stability in skeletally mature individuals following corpectomy or vertebrectomy. The system is comprised of spacers of various heights and footprints to fit the anatomical needs of a wide variety of patients. Each spacer has an axial hole to allow grafting material to be packed inside of the spacer. Protrusions on the superior and inferior surfaces of each device will grip the endplates of the adjacent vertebrae to resist expulsion. The XPand® devices are made from titanium alloy as specified in F136 and F1295. The XPand® Radiolucent Corpectomy Spacer devices are made from radiolucent polymer and titanium alloy as specified in ASTM F2026, F136 and F1295, and include markers made from titanium alloy or tantalum as specified in ASTM F136, F1295 and F560. ## FORTIFY® Corpectomy Spacers FORTIFY® and FORTIFY® Integrated Corpectomy Spacers are vertebral body replacement devices used to provide structural stability in skeletally mature individuals following corpectomy or vertebrectomy. The components include a central core and endplates, which are available in a range of sizes and options to accommodate the anatomical needs of a wide variety of patients. The core and endplates can be preoperatively or intraoperatively assembled to best fit individual requirements. Each spacer has an axial hole to allow autogenous bone graft or allograft to be packed inside of the spacer. Protrusions (teeth) on the superior and inferior surfaces grip the endplates of the adjacent vertebrae to resist expulsion. Additional spikes are available on some implants. {12}------------------------------------------------ FORTIFY® Integrated endplates have an integrated plate to accommodate screws for additional fixation and are assembled to the core. FORTIFY® and FORTIFY® I Corpectomy Spacers are manufactured from titanium allov per ASTM F136 and F1295. FORTIFY®-R and FORTIFY® I-R Corpectomy Spacers are manufactured from radiolucent PEEK OPTIMA LT1, with titanium alloy and tantalum components, per ASTM F2026, F136, F1295, and F560. Screws are manufactured from titanium alloy per ASTM F136 and F1295, with or without hydroxyapatite coating per ASTM F1185. #### NIKO® Corpectomy Spacers The NIKO® Corpectomy Spacer device is a vertebral body replacement device used to provide structural stability in skeletally mature individuals following corpectomy or vertebrectomy. The system is comprised of spacers of various fixed heights to fit the anatomical needs of a variety of patients. Each spacer has an axial hole to allow grafting material to be packed inside of the spacer. Protrusions on the superior and inferior surfaces of each device will grip the endplates of the adjacent vertebrae to resist expulsion. The NIKO® Corpectomy Spacer device is made from radiolucent polymer and titanium alloy or tantalum as specified in ASTM F2026, F136, F1295, and F560. #### RISE® Spacers RISE® Spacers are lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. RISE® Spacers are provided in different shapes to accommodate various surgical approaches to the lumbar spine (posterior, transforaminal [posterolateral] or lateral) and can expand to the desired height. The implants are available in various heights and geometric options to fit the anatomical needs of a wide variety of patients. This device is to be filled with autogenous bone graft material. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to resist expulsion. RISE® Spacers are manufactured from titanium alloy, as specified in ASTM F136 and F1295. An internal component is manufactured from radiolucent PEEK polymer, as specified in ASTM F2026. ## ALTERA™ Spacers The ALTERA™ Spacer is an expandable lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. The ALTERA™ Spacer accommodates various surgical approaches to the lumbar spine (posterior or transforaminal [posterolateral]) and allows articulation upon insertion. The devices are available in various height ranges, allowing continuous expansion within the range, to fit the anatomical needs of a wide variety of patients. This device is to be filled with autogenous bone graft material. Protrusions on the superior and inferior {13}------------------------------------------------ surfaces of each device grip the endplates of the adjacent vertebrae to resist expulsion. The ALTERA™ Spacer is made from titanium alloy, as specified in ASTM F136, F1295. and F1472. Internal components are made from radiolucent PEEK polymer and cobalt chromium molybdenum alloy, as specified in ASTM F2026 and F1537, respectively. #### MAGNIFY™ Spacers MAGNIFY™ Spacers are expandable anterior lumbar interbody fusion devices used to provide structural stability in skeletally mature individuals following discectomy. The devices are available in various height expansion ranges and geometric options to fit the anatomical needs of a wide variety of patients. Protrusions on the superior and inferior surfaces of each device grip the endplates of the adjacent vertebrae to aid in expulsion resistance. These devices are to be filled with autogenous bone graft material. The MAGNIFY™ Spacer is to be used with supplemental fixation. The MAGNIFY™-S Spacer is to be used with three titanium alloy screws that accompany the implant. MAGNIFY™ Spacers are manufactured from titanium alloy, as specified in ASTM F136, and include an internal component manufactured from radiolucent PEEK polymer, as specified in ASTM F2026. The screws used with MAGNIFY™-S are manufactured from titanium allov, as specified in ASTM F136 and F1295, and are available with hydroxyapatite (HA) coating, as specified in ASTM F1185. ## Indications for Use: ## SUSTAIN® Spacers When used as lumbar intervertebral body fusion devices, SUSTAIN® and SUSTAIN® Radiolucent (SUSTAIN® R) Spacers are intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The SUSTAIN® and SUSTAIN® R Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the REVERE®, REVOLVE® or BEACON® Stabilization Systems. When used as cervical intervertebral body fusion devices, the SUSTAIN® and SUSTAIN® R Spacers are intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C2-T1) at one level. {14}------------------------------------------------ DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of non-operative treatment. The SUSTAIN® and SUSTAIN® R Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the ASSURE®, PROVIDENCE® or XTEND® Anterior Cervical Plate Systems. When used as vertebral body replacement devices, SUSTAIN® and SUSTAIN® R Spacers are intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged or unstable vertebral body due to tumor or trauma (i.e., fracture). The spacers are intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, anterior plate systems and anterior screw and rod systems). The interior of the spacer can be packed with bone grafting material. SUSTAIN® and SUSTAIN® R Spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. #### PATRIOT® Cervical Spacers PATRIOT® Spacers (COLONIAL® ACDF) are interbody fusion devices intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C3-T1) at one level. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of non-operative treatment. PATRIOT® Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the ASSURE® or PROVIDENCE® Anterior Cervical Plate System. #### PATRIOT® Lumbar Spacers PATRIOT® Spacers (including Constitution®, Constitution® TPS, Signature®, Signature® TPS, Continental®, Continental® TPS, TransContinental®, TransContinental® TPS, TransContinental® M and TransContinental® M TPS) are interbody fusion devices intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc as confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). PATRIOT® Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation systems that have been cleared for use in the lumbosacral spine (e.g. posterior pedicle screw and rod systems, anterior plate systems, and anterior screw and rod systems). Hyperlordotic interbody devices (≥20° lordosis) must be used with at least anterior supplemental fixation. {15}------------------------------------------------ ## InterContinental® Plate-Spacer InterContinental® Plate-Spacers (including InterContinental® TPS) are lateral lumbar interbody fusion devices intended for use in patients with degenerative disc disease (DDD) at one or two contiquous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). InterContinental® Plate-Spacers are to be filled with autogenous bone graft material, and are to be used with two titanium alloy screws which accompany the implant. These devices are intended to be used with supplemental fixation (e.g. pedicle or facet screw systems) in addition to the integrated screws. ## CALIBER® Spacers CALIBER® Spacers are interbody fusion devices intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). CALIBER® Spacers are to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation, such as the REVERE® or REVOLVE® Stabilization Systems. ## COALITION® Spacers The COALITION® and COALITION AGX™ Spacers are interbody fusion devices intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C2-T1) at one level. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of non-operative treatment. These devices are to be filled with autogenous bone graft material. The COALITION® Spacer is a stand-alone interbody fusion device. The COALITION AGX™ Spacer is intended to be used with supplemental fixation such as the COALITION AGX™ Plate, ASSURE® PROVIDENCE™, VIP®, XTEND®, or UNIFY™ Anterior Cervical Plate Systems. When used with the COALITION AGX™ Plate, the assembly takes on the indications for use of the COALITION AGX™ Spacer, with the COALITION AGX™ Plate acting as the supplemental fixation. The COALITION AGX™ Plate is intended for anterior screw fixation to the cervical spine (C2-C7) for the following indications: degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc {16}------------------------------------------------ confirmed by patient history and radiographic studies), trauma (including fractures), tumors, deformity (defined as kyphosis, lordosis, or scoliosis), pseudarthrosis, failed previous fusion, spondylolisthesis, and spinal stenosis. #### INDEPENDENCE® Spacers INDEPENDENCE® (including INDEPENDENCE® MIS, INDEPENDENCE® TPS, and INDEPENDENCE® MIS TPS) Spacers are interbody fusion devices intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). INDEPENDENCE® Spacers are to be filled with autograft bone and/or allogenic bone graft composed of cancellous and/or corticocancellous bone. The INDEPENDENCE® Spacer is a stand-alone interbody fusion device intended to be used with three titanium alloy screws which accompany the implant. The INDEPENDE® MIS Spacer is an interbody fusion device to be used with three titanium alloy screws or anchors which accompany the implants. When used with screws, the INDEPENDENCE® MIS Spacer is a stand-alone interbody fusion device. When used with anchors, the INDEPENDENCE® MIS Spacer is intended for use with supplemental fixation (e.g. facet screws or posterior fixation). Hyperlordotic implants (≥25° lordosis) are intended for use with supplemental fixation (e.g. facet screws or posterior fixation). ## MONUMENT™ Spacers The MONUMENT™ Spacer is an interbody fusion device intended for use in patients with deqenerative disc disease (DDD) at one or two contiquous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The MONUMENT™ Spacer is to be filled with autogenous bone graft material, and is to be used with four titanium alloy screws that accompany the implant. The device is intended to be used with supplemental fixation (i.e. pedicle screws, facet fixation). ## XPand® Corpectomy Spacers The XPand® and XPand® Radiolucent Corpectomy Spacers are vertebral body replacement devices intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable vertebral body due to tumor or trauma (i.e., fracture). The XPand® and XPand® Radiolucent Corpectomy Spacers are intended to be used with supplemental spinal fixation systems that {17}------------------------------------------------ have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, anterior plate systems, and anterior screw and rod systems). The interior of the spacer can be packed with bone grafting material. The XPand® and XPand® Radiolucent Corpectomy Spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. ## FORTIFY® Corpectomy Spacers FORTIFY® (FORTIFY® and FORTIFY®-R) and FORTIFY® Integrated (FORTIFY® I and FORTIFY® I-R) Corpectomy Spacers are vertebral body replacement devices intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable vertebral body due to tumor or trauma (i.e., fracture). These devices are intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, anterior plate systems, and anterior screw and rod systems). The interior of the spacers can be packed with autogenous bone graft or allograft. These spacers are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. ## NIKO® Corpectomy Spacers The NIKO® Corpectomy Spacer is a vertebral body replacement device intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable vertebral body due to tumor or trauma (i.e., fracture). The NIKO® Corpectomy Spacer is intended to be used with supplemental spinal fixation systems that have been labeled for use in the thoracic and/or lumbar spine (i.e., posterior pedicle screw and rod systems, anterior plate systems, and anterior screw and rod systems). The interior of the spacer can be packed with bone grafting material. The NIKO® Corpectomy Spacer is designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. ## RISE® Spacers The RISE® Spacer is a lumbar interbody fusion device intended for use in patients with deqenerative disc disease (DDD) at one or two contiquous levels of the lumbosacral spine (L2-S1). DDD is defined as discoqenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The RISE® Spacer is to be filled with autogenous bone graft material. This device is intended to be used with supplemental fixation, such as the REVERE® or REVOLVE® Stabilization Systems. ## ALTERA™ Spacers {18}------------------------------------------------ The ALTERA™ Spacer is an interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discoqenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The ALTERA™ Spacer is to be filled with autogenous bone graft material. These devices are intended to be used with supplemental fixation. #### MAGNIFY™ Spacers The MAGNIFY™ Spacer is an interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiguous levels of the lumbosacral spine (L2-S1). DDD is defined as discoqenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The MAGNIFY™ Spacer is to be filled with autogenous bone graft material, and is to be used with supplemental fixation, such as the CREO®, REVERE® or REVOLVE® Stabilization Systems. The MAGNIFY™-S Spacer is a stand-alone interbody fusion device intended for use in patients with degenerative disc disease (DDD) at one or two contiquous levels of the lumbosacral spine (L2-S1). DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) months of non-operative treatment. In addition, these patients may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). The MAGNIFY™-S Spacer is to be filled with autogenous bone graft material, and is to be used with three titanium alloy screws that accompany each implant. #### Basis of Substantial Equivalence: The subject devices have been found to be substantially equivalent to the predicate devices with respect to technical characteristics, performance, and intended use. Performance testing was assessed by comparing the mechanical performance of subject and predicate systems per ASTM F2077. The information provided within this premarket notification supports substantial equivalence of the subject devices to the predicate devices. The subject devices perform as well as or better than the predicate devices.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...