K992052 · Invacare Corp. · INI · Aug 12, 1999 · Physical Medicine
Device Facts
Record ID
K992052
Device Name
MODELS LYNX AND PANTHER MOTORIZED SCOOTERS
Applicant
Invacare Corp.
Product Code
INI · Physical Medicine
Decision Date
Aug 12, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3800
Device Class
Class 2
Indications for Use
The intended use of the Lynx and Panther scooters is to is provide mobility to persons limited to a seated position.
Device Story
Motorized three-wheeled (Lynx) and four-wheeled (Panther) scooters; provide mobility for individuals limited to seated position. Components: welded steel frame, transaxle motor drive, braking system, adjustable seat, tiller steering, throttle control. Power: two 12V DC batteries. Operation: user-controlled via tiller and throttle for forward/reverse motion. Intended for indoor/outdoor use. Panther MX-4 model features heavy-duty construction for users up to 400 lbs; others rated for 200-250 lbs. Electronic motor controllers (Penny & Giles Solo 60 or 110) manage drive system. Benefit: provides independent mobility for mobility-impaired users.
Clinical Evidence
Bench testing only. Devices demonstrated compliance with ANSI/RESNA WC/14 (1991) and ISO 7176: 1993 (E) standards for power and control systems of electric wheelchairs.
Technological Characteristics
Welded steel frame; rear-wheel drive; transaxle motor drive; electronic motor controller (Penny & Giles Solo 60/110); tiller steering; throttle control. Power: two 12V DC batteries. 3-wheel (Lynx) or 4-wheel (Panther) configurations. Standards: ANSI/RESNA WC/14 (1991), ISO 7176: 1993 (E).
Indications for Use
Indicated for persons limited to a seated position requiring motorized mobility assistance.
Regulatory Classification
Identification
A motorized three-wheeled vehicle is a gasoline-fueled or battery-powered device intended for medical purposes that is used for outside transportation by disabled persons.
{0}------------------------------------------------
AUG 12 -
K992053
# 510(k) SUMMARY INVACARE CORPORATION'S 510(k) PREMARKET NOTIFICATION MODELS LYNX AND PANTHER MOTORIZED SCOOTERS
Submitter's Name, Address, Telephone Number, Contact Person and Date Prepared.
Invacare Corporation One Invacare Way Elyria, Ohio 44036 Phone: (440) 329-6000 Facsimile: (440) 365-4558
Contact Person: Edward A. Kroll Director, TQM and Regulatory Affairs Date Prepared: June 11, 1999
Name of Device and Name/Address of Sponsor: Models Lynx and Panther Motorized Scooters.
Invacare Corporation One Invacare Way Elyria, Ohio 44036 Phone: (440) 329-6000 Facsimile: (440) 366-9724
Common or Usual Name Scooter
Classification Name Motorized Three Wheel Vehicle
Predicate Devices
Products which are substantially equivalent to the Model Lynx and Panther Scooters are; Invacare Action Cat three wheeled scooter (K962583, 12/18/96) the Mega Motions Inc. Mega 4 scooter (K982144, 4/14/99), and the Pride Mobility Inc. Celebrity (K944939, 11/7/94).
Intended Use
The intended use of the Lynx and Panther scooters is to is provide mobility to persons limited to a seated position.
{1}------------------------------------------------
There are two models of Scooters in the Panther series. These are the Panther LX - 4 and the Panther MX - 4. A brief description of each is as follows.
#### Panther LX - 4
The Panther LX - 4 scooter is basically the same as the Lynx LX - 3 scooter except that the Panther LX -4 is a four wheeled vehicle whereas the Lynx LX - 3 is a three wheeled vehicle. It includes the same transaxle motor drive system, braking system, adjustable seat, upholstery, covers, tiller handle and throttle control as the Lynx LX - 3. Additionally, it incorporates the same Penny & Giles "Solo 60" motor controller and the Lynx version and it has an on board battery charger.
Because the Panther LX - 4 is a four wheel vehicle, the welded steel frame is slightly different than the Lynx version. While the rear section of the frame is basically the same, the front portion differs such that it can accept two front wheels as opposed to one wheel on the Lynx. With these exceptions, the Panther LX - 4 is basically the same as the Lynx LX - 3.
#### Panther MX - 4
The Panther MX - 4 is the largest scooter in the Invacare Lynx/Panther. Like the Panther LX -4 , the Panther MX - 4 is a four wheeled vehicle. It has the same intended function and use as the others, and consists of the same technology and construction. Like the others, it basically consists of a welded steel frame, transaxle drive mechanism. braking system and seat assembly. Also, it includes a tiller handle for steering, and a throttle control to engage and disengage scooter motion in both the forward and reverse directions.
The Panther MX - 4 differs from the others in the Lynx/Panther series in that it is designed as a heavy duty, more durable scooter with a recommended weight limitation of 400 lbs. maximum. It is larger and heavier than the others, and includes more options and features. As such the frame, transaxle drive and braking system are different from the others and , the Panther MX - 4 scooter is powered using a Penny & Giles model "Solo 110" motor controller.
#### Substantial Equivalence
Products which are substantially equivalent to the Invacare Action Cat three wheeled scooter (K962583, 12/18/96) the Mega Motions Inc. Mega 4 scooter (K982144, 4/14/99), and the Pride Mobility Inc. Celebrity (K944939, 11/7/94). Each of these products are motorized, three and four wheeled scooters with the same intended function and use of providing mobility to persons limited to a seated position. All are all constructed from the same basic materials and components, all have the same basic operational principles and all use DC batteries as their source of power. Drive mechanisms and braking systems are also similar as are performance specifications for speed, acceleration, deceleration, turning radius and braking.
{2}------------------------------------------------
Technological Characteristics and Substantial Equivalence
## Device Description
The Invacare Models Lynx and Panther scooters are motor driven indoor and outdoor transportation vehicles. The Lynx series of scooters are three-wheeled vehicles while the Panther Series of scooters are four-wheeled vehicles.
All of the scooters products are basic conventional rear wheel drive, rigid frame vehicles that are battery powered, and include various options and accessories depending upon user needs and preferences. They all consist primarily of a welded steel frame, transaxle motor drive system, braking system, electronic motor controller and an adjustable seat. Like most scooters, they include a tiller handle for steering, and a throttle control to engage and disengage scooter motion in both the forward and reverse directions. They are all powered by two (2) 12 volt DC batteries, and they all include a variety of options and accessories in order to meet the needs and preferences of various users.
## LYNX SERIES SCOOTERS
## Lynx SX-3 and SX-3P
As stated above the Lynx series of scooters are three-wheeled vehicles as opposed to the Panther series which are four wheeled. The Lynx series includes three different models These are the Lynx SX-3, Lynx SX-3P and the Lynx LX-3. The models are basically same with a few subtle differences.
The SX 3 and SX 3P differ only in that the SX - 3 includes an "on board" battery charger, which is fixed to the scooter, while the SX - 3P requires a remote and separate battery charger. There are also certain cosmetic differences such as shroud color availability, bumper trim, wood grain decorative decals and the like, which are included on the SX-3 version, but, not on the SX 3P version.
#### Lynx LX-3
The Lynx LX-3 scooter is similar to the Lynx SX-3 and SX-3P, but, is stightly larger. Like the SX-3 and SX3P, it is a three-wheel vehicle. However, it is designed to be a more heavy duty version scooter, with higher maximum weight capacity than the others in the Lynx series. Where the SX versions are rated for a maximum user weight of 200 lbs., the LX-3 version is rated for a maximum user weight of 250lbs.
#### PANTHER SERIES
The Invacare Models Panther scooters are motor driven indoor and outdoor four wheeled transportation vehicles. Like the Lynx series of scooters these products are basic conventional rear wheel drive, rigid frame vehicles that are battery powered, and include various options and accessories depending upon user needs and preferences. They also consist primarily of a welded steel frame, transaxle motor drive system, braking system, electronic motor controller and an adjustable seat. They include a tiller handle for steering, and a throttle control to engage and disengage scooter motion in both the forward and reverse directions, and are powered by two (2) 12 volt DC batteries.
{3}------------------------------------------------
# PERFORMANCE DATA
The Invacare Models Lynx and Panther scooters meet the applicable requirements specified in the Rehabilitation Engineering Society of North America (RESNA) Standard ANSI/RESNA WC/14 (1991) and ISO Standard ISO 7176: 1993 (E) "ISO Standard, Wheelchairs - Requirements and Test Methods for the Power and Control Systems of Electric Wheelchairs
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which features three parallel lines curving upwards and to the right, resembling a bird in flight. The caduceus is enclosed within a circular border, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the border of the circle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
AUG 1:2 1999
Mr. Edward A Kroll Director, TOM and Regulatory Affairs Invacare® Corporation One Invacare Way P.O. Box 4028 Elyria, Ohio 44036-2125
Re: K992052
> Trade Name: Models "Lynx" and "Panther" metorized scooters Regulatory Class: II Product Code: INI Dated: June 17, 1999 Received: June 18, 1999
Dear Mr. Kroll:
We have reviewed your Section 510(k) notification of intent to market the device referenced above, and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subiect to the general control provisions of the Act. The general control provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General Regulation (21 CFR Part 820), and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{5}------------------------------------------------
Page 2 -- Mr. Edward A. Kroll
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally. for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
## 510(k) Number (if known): TBD
Device Name: Invacare Models Lynx and Panther Motorized Scooters
Indications For Use: To provide mobility to persons limited to a seated position..
# (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
OR
Over-The-Counter Use
(Optional Format 1-2-96)
K992052
(Division Sign-Off) (Division of General Restorative Devices 510(k) Number .
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.