IMAGESHARE COMPUTED RADIOGRAPHY ACQUISITION STATION AND/OR SOFTWARE(2100{SIKARUS X86}/(1500{WINDOWS NT}
K973421 · Dejarnette Research Systems · LMD · Dec 5, 1997 · Radiology
Device Facts
Record ID
K973421
Device Name
IMAGESHARE COMPUTED RADIOGRAPHY ACQUISITION STATION AND/OR SOFTWARE(2100{SIKARUS X86}/(1500{WINDOWS NT}
Applicant
Dejarnette Research Systems
Product Code
LMD · Radiology
Decision Date
Dec 5, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.2020
Device Class
Class 1
Attributes
Software as a Medical Device
Indications for Use
The Imageshare Computed Radiography Acquisition Station and/or Software is a bi-directional gateway that sends or receives digital images to/from various image sources (including, but not limited to, Fuji CR, Fuji HI-C654, Analogic Corporation's DASM, Computed Radiography or Direct Radiography devices). The incoming data formats may be raw CR data, processed CR data or data formats proprietary to the modality source vendor. The Imageshare Computed Radiography Acquisition Station and/or Software converts the data to DICOM, ACR-NEMA v2.0, SPI format or other proprietary data format and transmits the data to one or more user-specified nodes across a standard, general purpose computing network.
Device Story
Device functions as bi-directional gateway for digital medical images; receives raw or proprietary CR/DR data from imaging modalities; converts data formats to DICOM, ACR-NEMA v2.0, or SPI; transmits images across general-purpose computing networks to user-specified nodes. Operates on off-the-shelf general-purpose computer hardware. Stores data locally on hard disk until destination acknowledgment. Ensures image delivery via power-loss recovery mechanism. Used in clinical environments to facilitate interoperability between disparate imaging systems and network destinations. Enables healthcare providers to access and route diagnostic images for clinical review.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Software-based gateway running on off-the-shelf general-purpose computer hardware. Supports conversion between proprietary modality formats and DICOM, ACR-NEMA v2.0, or SPI. Network-based connectivity via standard computing networks. Local hard disk storage for transmission buffering.
Indications for Use
Indicated for use as a bi-directional gateway for the transmission and conversion of digital medical images between various imaging modalities (CR/DR) and network nodes. No specific patient population, age, or disease state contraindications are defined.
Regulatory Classification
Identification
A medical image communications device provides electronic transfer of medical image data between medical devices. It may include a physical communications medium, modems, and interfaces. It may provide simple image review software functionality for medical image processing and manipulation, such as grayscale window and level, zoom and pan, user delineated geometric measurements, compression, or user added image annotations. The device does not perform advanced image processing or complex quantitative functions. This does not include electronic transfer of medical image software functions.
Predicate Devices
Imageshare Computed Radiography Acquisition Station and/or Software (K973421)
Submission Summary (Full Text)
{0}------------------------------------------------
## 1. 510(k) Summary
遭失彩,一直
## 510(k) Summary
[As required by 21 CFR 807.92(c)]
### Submitter Information 1.0
| 1.1 DeJarnette Research Systems<br>401 Washington Avenue Suite 700<br>Towson MD 21204 | 1.2 Contact: | Eric John Finegan |
|---------------------------------------------------------------------------------------|--------------|---------------------|
| | Voice: | +1 (410) 583 - 0680 |
| | Fax: | +1 (410) 583 - 0696 |
| | E-mail: | info@dejarnette.com |
8 Sept 1997 1.3 Date Prepared:
### Device Identification 2.0
- Imageshare Computed Radiography Acquisition Station and/or Software 2.1 Trade Name:
- Gateway to Digital Imaging Network Common Name: 2.2
- System, Digital Image Communication, accessory Classification Name: 2.3
## 3.0 Predicate Devices
Imageshare Computed Radiography Acquisition Station and/or Software [DeJarnette Research Systems, Inc.]
### 4.0 Device Description
- 4.1 Function:
The Imageshare Computed Radiography Acquisition and/or Software is designed to operate on a general purpose computer system running an image acquisition software application to receive, reformat and transmit image and demographic information. The system receives the image messages from a Computed Radiography or other image source and routes them automatically through a conversion to a destination based on information contained in the message source, encoded data or data entered or configured by an operator through a user interface. The Imageshare Computed Radiography Acquisition stores the data on its local hard disk until the destination acknowledges the successful transmission. Image delivery is also guaranteed when the Imageshare Computed Radiography Acquisition Station loses power and is restarted.
- Physical and Performance Characteristics: 4.2
The Imageshare Computed Radiography Acquisition Station and/or Software is designed to run on off-the-shelf, general purpose comment. The application software is designed for maximum portability across operating systems and hardware platforms. Performance of the application software is primarily a function of network load; secondarily a function of the hardware platform's computational speed. Intrinsic performance of the application does not change significantly as it is ported from one operating system to another.
111
{1}------------------------------------------------
## 5.0 Intended Use:
影视
The Imageshare Computed Radiography Acquisition Station and/or Software is a bi-directional gateway that sends or receives digital images to/from various image sources (including, but not limited to, Fuji CR, Fuji HI-C654, Analogic Corporation's DASM, Computed Radiography or Direct Radiography devices). The incoming data formats may be raw CR data, processed CR data or data formats proprietary to the modality source vendor. The Imageshare Computed Radiography Acquisition Station and/or Software converts the data to DICOM, ACR-NEMA v2.0. SPI format or other proprietary data format and transmits the data to one or more userspecified nodes across a standard, general purpose computing network.
### Statement of Substantial Equivalence: 6.0
The Imageshare Computed Radiography Acquisition Station and/or Software is substantially equivalent to previously marketed devices (as listed above in Part 3) in design, composition, function, intended use, safety and efficacy. No new issues of safety and effectiveness are raised.
Any differences between the Imageshare Computed Radiography Acquisition Station and the predicate device have no significant influence on safety or efficacy.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows a logo for the Department of Health and Human Services. The logo features a stylized eagle with three curved lines representing its wings. The word "DEPARTMENT" is written vertically along the left side of the logo.
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Eric John Finegan Regulatory Manager DEJARNETTE Research Systems 401 Washington Avenue Suite 700 Towson, MD 21204
Re: K973421
Imageshare Computed Radiography Acquisition Station and/or Software Dated: September 8, 1997 Received: September 10, 1997
Unclassified/Procode: 90 LMD
DEC - 5 1997
POW.SONG, MD., M.SC.
Dear Mr. Finegan:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and probibitions against misbranding and adulteration.
If your device is classified (see above) into either class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent decemination assumes compliance with the Current Good Manufacturing Practice
rirement, as set forth in the Quality System Regulation (QS) for Modical Devices: General regulation (21 CFR Part 820) and through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply whithe GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket aothirestion. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (2) CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compilance at (301) 594-4613. Additionally, for questions and advertising of your device, please contact the Office of Compliance at (307) 594-4639. Also, please note the regulation entitled, "Mishanding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free mumber (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/edrh/dsmamain.html".
Sincerely yours,
h.Liau Yu
Lillian Yin, Ph.D.
Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
德尔···········································································································································································
## 2. Statement of Indications for Use
Device: Imageshare Computed Radiography Acquisition Station and/or Software
# Statement of Indications for Use
[As required by 21 CFR 801.109]
# The Imageshare Computed Radiography Acquisition Station and/or
Software is a bi-directional gateway that sends or receives digital images to/from various image sources (including, but not limited to, Fuji CR, Fuji HI-C654, Analogic Corporation's DASM, Computed Radiography or Direct Radiography devices). The incoming data formats may be raw CR data, processed CR data or data formats proprietary to the modality source vendor. The Imageshare Computed Radiography Acquisition Station and/or Software converts the data to DICOM, ACR-NEMA v2.0, SPI format or other proprietary data format and transmits the data to one or more user-specified nodes across a standard, general purpose computing network.
(PLEASE DO NOT WRITE BELOW THIS LINE CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(División Sign-Off)
Division of Reproductive, Abdominal, ENT,
and Radiological Devices
510(k) Number K913467
| <strong>Labels</strong> | <strong>Values</strong> |
|-------------------------|-------------------------|
| Prescription Use | HRS |
| (Per 21 CFR 801.109) | |
| OR | |
| Over-The-Counter Use | |
2-1
Page
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.