K260376 · Shandong Huge Dental Material Corporation · EBI · May 6, 2026 · Dental
Device Facts
Record ID
K260376
Device Name
Denture Base
Applicant
Shandong Huge Dental Material Corporation
Product Code
EBI · Dental
Decision Date
May 6, 2026
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3760
Device Class
Class 2
Indications for Use
Denture Base is a light-curable resin indicated for the fabrication and repair of removable denture bases in dental laboratories, including full and partial dentures as well as immediate dentures, and baseplates. Denture Base can also be used for the fabrication of try-in dentures for the evaluation before fabricating the final dentures. Denture Base can be utilized as an aid in bonding the denture teeth onto denture base.
Device Story
Denture Base is a light-curable methacrylate-based resin used for additive manufacturing of dental prosthetics. Input data consists of digital denture base files derived from optical impressions. The device is processed via a 3D printer that solidifies the liquid resin layer-by-layer using UV light-activated polymerization. Used in dental laboratories by technicians to fabricate rigid, functional denture bases, try-in dentures, and baseplates. The final output is a custom dental appliance. Healthcare providers use the output to restore patient dentition. Benefits include precise, patient-specific dental prosthetics manufactured via digital workflows.
Clinical Evidence
No clinical data. Substantial equivalence supported by bench testing per ISO 20795-1 (flexural strength, modulus, fracture work, sorption, solubility, residual monomer) and biocompatibility testing per ISO 7405 and ISO 10993 (cytotoxicity, sensitization, irritation, systemic toxicity, genotoxicity). Additive manufacturing parameters verified per FDA guidance.
Technological Characteristics
Methacrylate-based light-curable resin; liquid form. Curing via UV light. Additive manufacturing (3D printing). Non-sterile. Complies with ISO 20795-1 (Type 4 material), ISO 7405, and ISO 10993. Shelf life 18 months.
Indications for Use
Indicated for fabrication and repair of removable denture bases, including full, partial, and immediate dentures, baseplates, and try-in dentures in dental laboratories; also used as an aid in bonding denture teeth to denture bases.
Regulatory Classification
Identification
A denture relining, repairing, or rebasing resin is a device composed of materials such as methylmethacrylate, intended to reline a denture surface that contacts tissue, to repair a fractured denture, or to form a new denture base. This device is not available for over-the-counter (OTC) use.
Predicate Devices
Dentca Base Premium, Dentca Base Hi-Impact (K220042)
{0}
FDA U.S. FOOD & DRUG ADMINISTRATION
May 6, 2026
Shandong Huge Dental Material Corporation
Zheng Maggie
Regulatory Affairs Manager
# 68 Shanhai Rd., Donggang District
Rizhao City, 276800
CHINA
Re: K260376
Trade/Device Name: Denture Base
Regulation Number: 21 CFR 872.3760
Regulation Name: Denture Relining, Repairing, Or Rebasing Resin
Regulatory Class: Class II
Product Code: EBI
Dated: February 5, 2026
Received: February 5, 2026
Dear Zheng Maggie:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov
{1}
K260376 - Zheng Maggie
Page 2
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13485 clause 8.3 (Nonconforming product), ISO 13485 clause 8.5.2 (Corrective action), and ISO 13485 clause 8.5.3 (Preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and ISO 13485 clause 7.5) and document changes and approvals in the Medical Device File (ISO 13485 clause 4.2.3).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-
{2}
K260376 - Zheng Maggie
Page 3
assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
MICHAEL E. ADJODHA -S
Michael E. Adjodha, MChE, RAC, CQIA
Assistant Director
DHT1B: Division of Dental and ENT Devices
OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT, and Dental Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health
Enclosure
{3}
FORM FDA 3881 (8/23)
Page 1 of 1
PSC Publishing Services (303) 443-6740
EF
| DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. |
| --- | --- |
| 510(k) Number (if known) K260376 | |
| Device Name Denture Base | |
| Indications for Use (Describe) Denture Base is a light-curable resin indicated for the fabrication and repair of removable denture bases in dental laboratories, including full and partial dentures as well as immediate dentures, and baseplates. Denture Base can also be used for the fabrication of try-in dentures for the evaluation before fabricating the final dentures. Denture Base can be utilized as an aid in bonding the denture teeth onto denture base. | |
| Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | |
| CONTINUE ON A SEPARATE PAGE IF NEEDED. | |
| This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* | |
| The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov | |
| "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." | |
{4}
HUGE
# 510 (k) Summary
K260376
This summary of 510(k) for the subjective device equivalence information is being submitted in accordance with the requirements of 21 C.F.R. 807.92.
1. Date Summary Prepared: May 05, 2026
2. Submitter Information:
Owner's Name: Shandong Huge Dental Material Corporation
Address: No. 68 Shanhai Road, Donggang District, Rizhao City, Shandong Province, 276800, P.R. China
Telephone: 0086 633 2277268
Fax: 0086 633 2277298
Contact Person: Ms. Maggie Zheng
Contact Title: Regulatory Affairs Manager
E-mail: zhengxy@hugedent.com
3. Device Name
Trade name: Denture Base
Common name: Denture Base
Classification name: Denture relining, repairing, or rebasing resin (21 CFR 872.3760)
Regulatory Class: Class II
Product Code: EBI
4. Predicate and Reference Device Information
| Owner/Operator | Device Name | 510 (k) No. | Product Code | Remarks |
| --- | --- | --- | --- | --- |
| Dentca, Inc. | Dentca Base Premium, Dentca Base Hi-Impact | K220042 | EBI | Primary predicate device |
| SPRINTRAY INC. | Apex Base (Light Pink, Original Pink, Dark Reddish Pink, Opaque Original Pink); High Impact Denture Base (Light Pink, Original Pink, Dark Pink, Light Meharry, Original Meharry, Bubblegum) | K221678 | EBI | Secondary predicate device |
Note: The secondary device is included to facilitate a comparative analysis of technological characteristics, thereby establishing a basis for determining the substantial equivalence of the subject device to legally marketed devices.
{5}
HUGE
## 5. Description of Device
Fabrication of dental prosthetics with Denture Base resin requires computer-aided design and manufacturing system that includes the following components not part of the device: oral casting impression, digital denture base file created in an optical impression system, 3D printer, and curing light equipment. The Denture Base consists of a curable dental acrylate resin that is designed to be used in conjunction with a scanned 3D image of a patient’s teeth, and 3D printer assembly, to locally manufacture out a dental appliance in dental offices based on the clinician’s judgment of patient need.
The Denture Base product operates on the principle of photoactivated polymerization to transform a malleable resin into a rigid, functional dental prosthesis. A software-driven 3D printer solidifies the liquid resin layer-by-layer through precise light exposure to build the final denture base geometry.
The Denture Base product family comprises a single device model (DB) offered in multiple shades. All variants are identical in their fundamental composition (methacrylate-based resin, photoinitiator, filler and color pastes/pigments), manufacturing process, and core technical performance specifications.
## 6. Indications for Use
Denture Base is a light-curable resin indicated for the fabrication and repair of removable denture bases in dental laboratories, including full and partial dentures as well as immediate dentures, and baseplates. Denture Base can also be used for the fabrication of try-in dentures for the evaluation before fabricating the final dentures. Denture Base can be utilized as an aid in bonding the denture teeth onto denture base.
## 7. Technological Characteristics Comparison
The following table shows the significant technological characteristics for the subject device and indicates the following similarities and differences with the predicate devices:
{6}
HUGE
| Feature | Subject device | Primary Predicate device | Secondary Predicate device | Conclusion |
| --- | --- | --- | --- | --- |
| | K260376 Denture Base | K220042 Dentca Base Premium, Dentca Base Hi-Impact | K221678 Apex Base (Light Pink, Original Pink, Dark Reddish Pink, Opaque Original Pink); High Impact Denture Base (Light Pink, Original Pink, Dark Pink, Light Meharry, Original Meharry, Bubblegum) | |
| Product Code | EBI | EBI | EBI | Same |
| Regulation | 21 CFR 872.3760 | 21 CFR 872.3760 | 21 CFR 872.3760 | Same |
| Indications of Use | Denture Base is a light-curable resin indicated for the fabrication and repair of removable denture bases in dental laboratories, including full and partial dentures as well as immediate dentures, and baseplates. Denture Base can also be used for the fabrication of try-in dentures for the evaluation before fabricating the final dentures. Denture Base can be utilized as an aid in bonding the denture teeth onto denture base. | DENTCA Base Resin is a light-curable resin indicated for the fabrication and repair of removable denture bases in dental laboratories, including full and partial dentures as well as immediate dentures, and baseplates. DENTCA Base Resin can also be used for the fabrication of try-in dentures for the evaluation before fabricating the final dentures. Fabrication of these prostheses with DENTCA Base Resin requires a digital denture file, additive printer, and curing light equipment. DENTCA Base Resin can be utilized as an aid in bonding the denture teeth onto denture base. | The SprintRay High Impact Denture Base resin is a light-curable polymerizable resin intended to be used for the fabrication and repair, of full and partial removable dentures and baseplates. The material is an alternative to traditional denture base material. | Similar[1] |
| Main Composition | Methacrylate-based resin | Methacrylate-based resin | Methacrylate-based resin | Similar |
| Material Type | Light-curable Resin | Light-curable Resin | Light-curable Resin | Similar |
| Curing Method | UV Light | UV Light | UV Light | Similar |
| Physical Form | Liquid | Liquid | Liquid | Same |
13-3
{7}
HUGE
| Feature | Subject device | Primary Predicate device | Secondary Predicate device | Conclusion |
| --- | --- | --- | --- | --- |
| | K260376 Denture Base | K220042 Dentca Base Premium, Dentca Base Hi-Impact | K221678 Apex Base (Light Pink, Original Pink, Dark Reddish Pink, Opaque Original Pink); High Impact Denture Base (Light Pink, Original Pink, Dark Pink, Light Meharry, Original Meharry, Bubblegum) | |
| Manufacturing Technology Type | Additive | Additive | Additive | Same |
| Shelf life | 18 months | 3 years | 1.5 years | Same |
| Prescription/over-the-counter use | Prescription | Prescription | Prescription | Same |
| Sterility | Non-sterile | Non-sterile | Non-sterile | Same |
| Package form | bottle | bottle | bottle | Same |
| Physical Properties | The subject device and predicate devices have substantially equivalent physical properties as they all conform to the applicable specifications set in ISO 20795-1 for Type 4 material. | | | Similar[2] |
| Biocompatibility | Biocompatible. The subject device and predicate devices meet the applicable requirements of ISO 7405 and ISO 10993 standards. | | | Similar |
| Additive Manufacturing | Testing, according to FDA’s guidance Technical Considerations for Additive Manufactured Medical Devices, was performed and results were provided in the 510(k). These tests included evaluation of all relevant properties of the printed resin using the permitted machines. Further, tests based on considerations of the orientation during manufacturing were performed. | | | Similar |
Note[1]: The subject device and the predicate devices have substantially the same indications for use. The minor differences in indications for use concerning try-in dentures and bonding do not affect the determination of substantial equivalence, as these differences represent a logical and clinically necessary extension of the device’s fundamental purpose as a denture base resin—a purpose that is fully aligned with that of the legally marketed primary predicate device (K220042).
Note[2]: The subject device was compared to the secondary predicate device(K221678) for technological characteristics. Testings were performed per ISO 20795-1 and internal standards, and the test results demonstrate that the subject device is substantially equivalent to the legally marketed predicate device(K221678) with respect to all key technological and physicochemical properties.
13-4
{8}
HUGE
## 8. Summary of Non-clinical testing
The physical properties of the subject device were determined according to ISO 20795-1 and internal standard. Bench testings were performed on the subject device and the secondary predicate device, the test results demonstrated the substantial equivalence when compared to the secondary predicate device. The main test items including: Homogeneity, Surface characteristics, Colour, Colour stability, Translucency, Freedom from porosity, Ultimate flexural strength, Flexural modulus, Maximum stress intensity factor for materials with improved impact resistance, Total fracture work, Bonding to synthetic polymer teeth, Sorption, Solubility, Residual methyl methacrylate monomer, Polishing performance, Dimensional Accuracy, Anisotropy (Post-curing).
Additionally, the compositions of the subject device do not contain any non-conventional chemicals compared to the legally marketed predicate devices. Biocompatibility tests were performed fully following the ISO 7405 and ISO 10993 standards, to demonstrate substantial equivalence to the predicate device in terms of biocompatibility, including Cytotoxicity, Skin sensitization, Irritation, Acute systemic toxicity, Subchronic systemic toxicity and Genotoxicity.
As per FDA guidance “Technical Considerations for Additive Manufactured Medical Devices”, 3D Printing Parameters and Cleaning Verification was performed to verify 3D printing parameters, leftover material reuse, post-processing cleaning parameters, post-curing light parameters, and 3D printer compatibility of the subject device through systematic experiments, ensuring the matching and stability of the parameters.
## 9. Clinical Performance Data
Clinical test is not applicable.
## 10. Conclusions
Based on the indications for use, technological characteristics, performance testing and comparison to predicate devices, the subject device has demonstrated substantial equivalence. Shandong Huge Dental Material Corporation concludes that the subject device is substantially equivalent to the predicate devices described herein.
13-5
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.