THUNDERBEAT 5 mm, 45 cm, Front-actuated Grip Type S (TB-0545FCS); THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip Type S (TB-0535FCS); THUNDERBEAT 5 mm, 20 cm, Front-actuated Grip Type S (TB-0520FCS)

K254056 · Olympus Medical Systems Corp. · GEI · Jul 1, 2026 · General, Plastic Surgery

Device Facts

Record IDK254056
Device NameTHUNDERBEAT 5 mm, 45 cm, Front-actuated Grip Type S (TB-0545FCS); THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip Type S (TB-0535FCS); THUNDERBEAT 5 mm, 20 cm, Front-actuated Grip Type S (TB-0520FCS)
ApplicantOlympus Medical Systems Corp.
Product CodeGEI · General, Plastic Surgery
Decision DateJul 1, 2026
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4400
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The THUNDERBEAT Type S hand instruments are intended to be used for open, laparoscopic, and endoscopic surgery to cut, seal, coagulate, grasp, and dissect. Seal & Cut mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal & Cut mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc) and endoscopic surgery or in any procedure in which cutting, vessel ligation (sealing and cutting), coagulation, grasping, and dissection is performed. These devices have been designed to seal and cut vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. Seal mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc), and endoscopic surgery or in any procedure in which vessel sealing, coagulation, grasping is performed. These devices have been designed to seal vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. The THUNDERBEAT Type S hand instruments have not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures, and should not be used for these procedures.

Device Story

THUNDERBEAT Type S hand instrument; surgical tool for cutting, sealing, grasping, dissecting tissue/vessels up to 7mm. Operates via ultrasonic vibration (47 kHz) and HF Bipolar energy; probe vibrates at ultrasonic frequencies while grasping section acts as electrode. Used in open, laparoscopic, endoscopic procedures; operated by surgeons. Compatible with Olympus generators (USG-400, ESG-400, USG-410, ESG-410). Provides vessel ligation and tissue coagulation; benefits include reduced surgical time and effective hemostasis. Single-use device; includes torque wrench and stabilizer.

Clinical Evidence

Bench testing only. No clinical data provided. Performance demonstrated via mechanical/durability testing, biocompatibility (ISO 10993-1), sterilization/shelf-life validation (ISO 11135, ISO 11607), and electrical safety/EMC testing (ANSI AAMI ES 60601-1, IEC 60601-1-2).

Technological Characteristics

Handheld surgical instrument; 20cm, 35cm, 45cm lengths. Ultrasonic frequency 47 kHz; amplitude 80 μm; HF bipolar voltage 229 Vp. 360-degree shaft rotation; 24.5N grasping force. Sterilized via Ethylene Oxide. Complies with ANSI AAMI ES 60601-1, IEC 60601-1-2, and ISO 10993 standards.

Indications for Use

Indicated for patients undergoing open, laparoscopic, or endoscopic surgery requiring tissue cutting, sealing, coagulation, grasping, and dissection. Applicable to general, gynecological, urologic, thoracic, and plastic/reconstructive surgeries. Contraindicated for tubal sterilization or tubal coagulation procedures.

Regulatory Classification

Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

Predicate Devices

Reference Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION July 1, 2026 Olympus Medical Systems Corp. % Susan Lewandowski Manager, Program Regulatory Affairs Olympus Corporation of the Americas 800 W. Park Dr. Westborough, Massachusetts 01581 Re: K254056 Trade/Device Name: THUNDERBEAT 5 mm, 45 cm, Front-actuated Grip Type S (TB-0545FCS); THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip Type S (TB-0535FCS); THUNDERBEAT 5 mm, 20 cm, Front-actuated Grip Type S (TB-0520FCS) Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical Cutting And Coagulation Device And Accessories Regulatory Class: Class II Product Code: GEI, LFL Dated: June 2, 2026 Received: June 2, 2026 Dear Susan Lewandowski: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K254056 - Susan Lewandowski Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13485 clause 8.3 (Nonconforming product), ISO 13485 clause 8.5.2 (Corrective action), and ISO 13485 clause 8.5.3 (Preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and ISO 13485 clause 7.5) and document changes and approvals in the Medical Device File (ISO 13485 clause 4.2.3). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory- {2} K254056 - Susan Lewandowski Page 3 assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Colin K. Chen -S Digitally signed by Colin K. Chen -S Date: 2026.07.01 15:18:48 -04'00' Colin K. Chen, Ph.D. Acting Assistant Director DHT4A: Division of General Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} | Indications for Use | | | | --- | --- | --- | | Please type in the marketing application/submission number, if it is known. This textbox will be left blank for original applications/submissions. | K254056 | ? | | Please provide the device trade name(s). | | ? | | THUNDERBEAT 5 mm, 45 cm, Front-actuated Grip Type S (TB-0545FCS); THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip Type S (TB-0535FCS); THUNDERBEAT 5 mm, 20 cm, Front-actuated Grip Type S (TB-0520FCS) | | | | Please provide your Indications for Use below. | | ? | | The THUNDERBEAT Type S hand instruments are intended to be used for open, laparoscopic, and endoscopic surgery to cut, seal, coagulate, grasp, and dissect. Seal & Cut mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal & Cut mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc) and endoscopic surgery or in any procedure in which cutting, vessel ligation (sealing and cutting), coagulation, grasping, and dissection is performed. These devices have been designed to seal and cut vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. Seal mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc), and endoscopic surgery or in any procedure in which vessel sealing, coagulation, grasping is performed. These devices have been designed to seal vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. The THUNDERBEAT Type S hand instruments have not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures, and should not be used for these procedures. | | | | Please select the types of uses (select one or both, as applicable). | ☑ Prescription Use (21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | ? | {4} OLYMPUS® THUNDERBEAT Type S Hand Instrument Traditional 510(k) Premarket Notification K254056 ### 510(k) Summary ### 1. General Information Date Prepared: June 26, 2026 510(K) submitter: Olympus Medical Systems Corporation 2951 Ishikawa-cho, Hachioji-shi, Tokyo Japan 192-8507 Contact: Norikiyo Shibata Email: norikiyo.shibata@olympus.com Correspondent: Olympus Surgical Technologies of America 800 West Park Drive, Westborough, MA 01581 Primary Contact: Susan Lewandowski Email: susan.lewandowski@olympus.com ### 2. Device Information Device Name: THUNDERBEAT Type S Hand Instrument Model Name: TB-0520FCS, TB-0535FCS, TB-0545FCS Common Name: Electrosurgical cutting and coagulation device Classification: 878.4400 – Electrosurgical, Cutting & Coagulation & Accessories Regulatory Class: II Product Code: GEI – Electrosurgical, Cutting & Coagulation & Accessories LFL – Instrument, Ultrasonic Surgical Device Panel: General and Plastic Surgery ### 3. Predicate Device Information | Device Name | 510(k) Submitter | 510(k) Number | | --- | --- | --- | | Ultrasonic Bipolar Generator USG-410 with accessories | Olympus Medical Systems Corporation | K211838 | Page 1 of 6 {5} OLYMPUS® THUNDERBEAT Type S Hand Instrument Traditional 510(k) Premarket Notification K254056 #### **4. Device Description** The THUNDERBEAT Type S Hand Instrument (TB-0520FCS, TB-0535FCS, and TB-0545FCS) is a functional device capable of sealing, cutting, grasping and dissecting vessels, tissue bundles, and lymphatic tissue up to 7mm in diameter during open, laparoscopic, and endoscopic surgical procedures. The TBS is used with a compatible ultrasonic generator and transducer. The hand instruments are available in three (3) lengths: 20cm, 35cm, and 45cm. The THUNDERBEAT Type S Hand Instrument has a probe and a grasping section at the distal tip of the shaft. The probe section is set inside of the shaft. The grasping section is pivotally connected to the shaft. The probe vibrates at ultrasonic frequencies and acts as an electrode for the HF Bipolar output. The grasping section acts as the other electrode for the HF Bipolar output. A non-medical device torque wrench and a stabilizer are included in the packaging of each instrument. #### **5. Indications for Use** The THUNDERBEAT Type S hand instruments are intended to be used for open, laparoscopic, and endoscopic surgery to cut, seal, coagulate, grasp, and dissect. Seal & Cut mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal & Cut mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc) and endoscopic surgery or in any procedure in which cutting, vessel ligation (sealing and cutting), coagulation, grasping, and dissection is performed. These devices have been designed to seal and cut vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. Seal mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc), and endoscopic surgery or in any procedure in which vessel sealing, coagulation, grasping is performed. These devices have been designed to seal vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. The THUNDERBEAT Type S hand instruments have not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures, and should not be used for these procedures. Page 2 of 6 {6} OLYMPUS® THUNDERBEAT Type S Hand Instrument Traditional 510(k) Premarket Notification K254056 # 6. Predicate Comparison | Item | Subject Device THUNDERBEAT Type S Hand Instrument | Predicate Device THUNDERBEAT Type S Hand Instrument | Comments on Difference | | --- | --- | --- | --- | | Manufacturer | OLYMPUS MEDICAL SYSTEMS CORP. | OLYMPUS MEDICAL SYSTEMS CORP. | Same | | Indications for Use | The THUNDERBEAT Type S hand instruments are intended to be used for open, laparoscopic, and endoscopic surgery to cut, seal, coagulate, grasp, and dissect. Seal & Cut mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal & Cut mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc) and endoscopic surgery or in any procedure in which cutting, vessel ligation (sealing and cutting), coagulation, grasping, and dissection is performed. These devices have been designed to seal and cut vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. Seal mode: The THUNDERBEAT Type S hand instruments when used in combination with the Seal mode are indicated for open, laparoscopic (including single-site surgery) general surgery and gynecological surgery (including urologic, thoracic, plastic and reconstructive, bowel resections, cholecystectomies, Nissen fundoplication, adhesiolysis, oophorectomy, hysterectomies (both vaginal assisted and abdominal) etc), and endoscopic surgery or in any procedure in which vessel sealing, coagulation, grasping is performed. These devices have been designed to seal vessels (up to and including 7 mm in diameter), tissue bundles, and lymphatics. The THUNDERBEAT Type S hand instruments have not been shown to be effective for tubal sterilization or tubal | Same | Page 3 of 6 {7} OLYMPUS® THUNDERBEAT Type S Hand Instrument Traditional 510(k) Premarket Notification K254056 | | coagulation for sterilization procedures, and should not be used for these procedures. | | | | --- | --- | --- | --- | | Single-Use/Reuse | Single Use | Single Use | Same | | Sterilization | Ethylene Oxide | Ethylene Oxide | Same | | Working Length (cm) | 20, 35, 45 | 20, 35, 45 | Same | | Shaft rotation | 360 degrees | 360 degrees | Same | | Grasping force (N) | 24.5±2 | 24.5±2 | Same | | Compatibility generator | -STMS USG-400 (K172691) -ESG-400 (K203682) -USG-410 (K211838) -ESG-410 (K231777) | -STMS USG-400 (K172691) -ESG-400 (K203682) -USG-410 (K211838) | Similar Compatibility of the THUNDERBEAT Type S was included in the respective cleared electrosurgical generators' 510(k)s. | | Mechanism of Cutting | Ultrasonic & High Frequency | Ultrasonic & High Frequency | Same | | Frequency | 47 kHz | 47 kHz | Same | | Amplitude | 80 μm | 80 μm | Same | | Rated high-frequency (RF bipolar) voltage | 229 Vp | 229 Vp | Same | ### 7. Comparison of Technological Characteristics with the Predicate Device Compared to the predicate device, the change to the subject device is limited to a design change to the jaw at the distal end of the device. These dimensional changes to the jaw subcomponents do not impact the final device design or specifications as compared to the predicate device. The jaw design change has been shown to be substantially equivalent to the predicate device through comparative bench testing. The 510(k) also included a list of non-reportable (documentation/Letter to File) changes made since the time of last clearance (K211838). Page 4 of 6 {8} OLYMPUS® THUNDERBEAT Type S Hand Instrument Traditional 510(k) Premarket Notification K254056 Technological similarities - The subject device and the predicate device are the same devices Technological differences - The jaw design is different between the subject and predicate device. These changes are at the subcomponent level and do not affect the established final device specifications. - The subject device was the focus of non-reportable changes which caused minor differences between the subject and predicate devices. These changes include documentation, labeling (editorial), manufacturing documentation/equipment, supplier. The differences in technological characteristics do not impact the safety and effectiveness of the subject device as demonstrated by Performance, Sterilization/Shelf life, EMC, and Biocompatibility testing. 8. Non-Clinical/Clinical Tests Summary and Conclusion Olympus performed non-clinical testing to demonstrate substantial equivalence to the predicate device. Test samples were final, finished devices subjected to the full manufacturing process including sterilization. The Mechanical and Durability performance bench tests were conducted to demonstrate substantial equivalence between the subject and predicate devices. All test samples passed pre-defined acceptance criteria. Sterilization and Shelf-Life Sterilization and shelf-life testing were conducted according to the recommendations in FDA Guidance Document, Submission and Review of Sterility Information in Premarket Notifications (510(k)) Submissions for Devices Labeled as Sterile, Issued January 8, 2024, as well as the following standards. - ISO 11135: 2014 - ISO 10993-7: 2008 [Including: ISO 10993-7:2008/COR 1:2009 and ISO 10993-7:2008/AMD 1:2019] - ASTM F1980-21 - ISO 11607-1: 2019 - ISO 11607-2: 2019 Biocompatibility The biocompatibility evaluation was conducted in accordance with the FDA Guidance Use of International Standard ISO 10993-1, “Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process”. The subject device is considered an external communicating device (tissue/bone/dentin) contacting for a duration of less than 24 hours. Page 5 of 6 {9} OLYMPUS® THUNDERBEAT Type S Hand Instrument Traditional 510(k) Premarket Notification K254056 The testing included the following tests: - Cytotoxicity - Sensitization - Irritation - Acute Systemic toxicity - Material Mediated Pyrogenicity EMC and Electrical Safety Electrical safety and EMC performance testing was conducted in accordance with the FDA Guidance Electromagnetic Compatibility (EMC) of Medical Devices, Guidance for Industry and Food and Drug Administration Staff, issued on June 6, 2022. The subject device is confirmed to comply with the relevant requirements as noted below. - ANSI AAMI ES 60601-1:2005+A1:2012+A2:2020 - IEC 60601-1-2:2014+A1:2021 - IEC TR 60601-4-2:2016 ### 9. Conclusion Based on the comparison to the predicate device, intended use, technological characteristics, and performance testing, the THUNDERBEAT Type S Hand Instrument raises no new issues of safety and effectiveness and is substantially equivalent to the predicate device in terms of safety, efficacy, and performance. Page 6 of 6
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...