SeaSpine Spacer System (NanoMetalene)- Hollywood, Hollywood VI, Ventura, Pacifica; SeaSpine Spacer System -Hollywood, Hollywood VI, Ventura, Pacifica; SeaSpine Vu e·POD System
K173260 · SeaSpine Orthopedics Corporation · MAX · Dec 4, 2017 · Orthopedic
Device Facts
Record ID
K173260
Device Name
SeaSpine Spacer System (NanoMetalene)- Hollywood, Hollywood VI, Ventura, Pacifica; SeaSpine Spacer System -Hollywood, Hollywood VI, Ventura, Pacifica; SeaSpine Vu e·POD System
Applicant
SeaSpine Orthopedics Corporation
Product Code
MAX · Orthopedic
Decision Date
Dec 4, 2017
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3080
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
When used as an intervertebral body fusion device, the system is intended for spinal fusion procedures at one or two contiguous levels (L2-S1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). These patients should have had six months of non-operative treatment. The device is intended to be used with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone and supplemental fixation. When used as a vertebral body replacement device (VBR) the Seaser System is intended for use in the thoracolumbar spine (T1 to L5) to replace a collapsed, damaged or unstable complete or partial vertebral body due to tumor or trauma/fracture, to achieve anterior decompression of the spinal tissues, and to restore the height of a collapsed vertebral body. The SeaSpine Spacer System is designed to restore the biomechanical integrity of the anterior, middle, and posterior spinal column, even in the absence of fusion for a prolonged period. Additionally, the SeaSpine Spacer System is intended for use with autograft bone graft come graft composed of cancellous and/or corticocancellous bone.
Device Story
Intervertebral body fusion and vertebral body replacement system; acts as disc spacer to hold autograft/allogeneic bone graft; promotes spinal fusion; restores biomechanical integrity of spinal column. Implants feature superior/inferior surface teeth and central canal. Used in surgical settings by orthopedic/neurosurgeons. Implants available in various shapes/sizes. NanoMetalene-coated versions provided sterile; PEEK versions provided non-sterile for facility-based steam sterilization. Instruments included for placement, adjustment, and removal.
Clinical Evidence
No clinical data provided. Substantial equivalence based on non-clinical bench testing and comparison of technological characteristics to predicate devices.
Technological Characteristics
Materials: PEEK (ASTM F2026), Tantalum markers (ASTM F560), Commercially pure titanium (ASTM F67) coating (NanoMetalene). Design: Interbody spacer with teeth and central graft canal. Sterilization: Gamma (NanoMetalene) or steam (PEEK).
Indications for Use
Indicated for skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels (L2-S1) with up to Grade 1 spondylolisthesis or retrolisthesis, or for thoracolumbar (T1-L5) vertebral body replacement due to tumor or trauma/fracture. Requires 6 months of failed non-operative treatment.
Regulatory Classification
Identification
An intervertebral body fusion device is an implanted single or multiple component spinal device made from a variety of materials, including titanium and polymers. The device is inserted into the intervertebral body space of the cervical or lumbosacral spine, and is intended for intervertebral body fusion.
Special Controls
*Classification.* (1) Class II (special controls) for intervertebral body fusion devices that contain bone grafting material. The special control is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intervertebral Body Fusion Device.” See § 888.1(e) for the availability of this guidance document.(2) Class III (premarket approval) for intervertebral body fusion devices that include any therapeutic biologic (e.g., bone morphogenic protein). Intervertebral body fusion devices that contain any therapeutic biologic require premarket approval.
(c)
*Date premarket approval application (PMA) or notice of product development protocol (PDP) is required.* Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). The FDA logo consists of two parts: the Department of Health and Human Services logo on the left and the FDA acronym along with the full name of the agency on the right. The Department of Health and Human Services logo features a stylized human figure, while the FDA part includes the acronym "FDA" in a blue square, followed by "U.S. FOOD & DRUG ADMINISTRATION" in blue text.
December 4, 2017
SeaSpine Orthopedics Corporation Ms. Gina Flores Sr. Regulatory Specialist 5770 Armada Drive Carlsbad, California 92008
### Re: K173260
Trade/Device Name: SeaSpine Spacer System (NanoMetalene)- Hollywood, Hollywood VI, Ventura, Pacifica; SeaSpine Spacer System -Hollywood, Hollywood VI, Ventura, Pacifica; SeaSpine Vu e·POD System Regulation Number: 21 CFR 888.3080 Regulation Name: Intervertebral Body Fusion Device Regulatory Class: Class II Product Code: MAX, MQP Dated: October 9, 2017 Received: October 10, 2017
Dear Ms. Flores:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820);
{1}------------------------------------------------
### Page 2 - Ms. Gina Flores
and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education (DICE) at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education (DICE) at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely.
# Katherine D. Kavlock -S
for Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K173260
#### Device Name
SeaSpine Spacer System (NanoMetalene)-Hollywood, Hollywood VI, Ventura, Pacifica
#### Indications for Use (Describe)
When used as an intervertebral body fusion device, the system is intended for spinal fusion procedures at one or two contiguous levels (L2-S1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). These patients should have had six months of non-operative treatment. The device is intended to be used with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone and supplemental fixation.
Type of Use (*Select one or both, as applicable*)
| <span></span> Prescription Use (Part 21 CFR 801 Subpart D) | <span></span> Over-The-Counter Use (21 CFR 801 Subpart C) |
|------------------------------------------------------------|-----------------------------------------------------------|
|------------------------------------------------------------|-----------------------------------------------------------|
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
# Indications for Use
510(k) Number (if known) K173260
#### Device Name
SeaSpine Spacer System- Hollywood, Hollywood VI, Ventura, Pacifica
#### Indications for Use (Describe)
When used as an intervertebral body fusion device, the system is intended for spinal fusion procedures at one or two contiguous levels (L2-S1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). These patients should have had six months of non-operative treatment. The device is intended to be used with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone and supplemental fixation.
When used as a vertebral body replacement device (VBR) the Seaser System is intended for use in the thoracolumbar spine (T1 to L5) to replace a collapsed, damaged or unstable complete or partial vertebral body due to tumor or trauma/fracture, to achieve anterior decompression of the spinal tissues, and to restore the height of a collapsed vertebral body. The SeaSpine Spacer System is designed to restore the biomechanical integrity of the anterior, middle, and posterior spinal column, even in the absence of fusion for a prolonged period. Additionally, the SeaSpine Spacer System is intended for use with autograft bone graft come graft composed of cancellous and/or corticocancellous bone.
Type of Use (Select one or both, as applicable)
| | <span style="padding-right: 5px;">☒</span> Prescription Use (Part 21 CFR 801 Subpart D) |
|--|-----------------------------------------------------------------------------------------|
| | <span style="padding-right: 5px;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) |
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
# Indications for Use
510(k) Number (if known) K173260
Device Name SeaSpine Vu e·POD System
#### Indications for Use (Describe)
When used as an intervertebral body fusion device, the Vu ePOD Intervertebral Body Fusion Device is indicated for use as an adjunct to fusion in patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1. These DDD patients may also have up to Grade 1 spondylolisthesis at the involved level(s). The device is indicated for use with autograft bone graft and/or allogeneic bone graft composed of cancellous bone. The Vu e•POD Intervertebral Body Fusion Devices are intended for use with supplemental fixation.
Degenerative disc disease (DDD) is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had six months of non-operative treatment.
When used as a vertebral body replacement (VBR) the Vu e·POD System is indicated for use in the thoracolumbar spine (TI-L5) to replace a collapsed, damaged or otherwise unstable vertebral body due to tumor or trauma (i.e. fracture). The Vu e POD VBR System is designed to restore the biomechanical integrity of the anterior, middle and posterior spinal column even in the absence of fusion for a prolonged period. The device is indicated for use with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone. The Vu ePOD VBR System is intended for use with supplemental internal spinal fixation.
Type of Use (Select one or both, as applicable)
| <span> <span style="font-size: 16px;">☑</span> Prescription Use (Part 21 CFR 801 Subpart D) </span> |
|-----------------------------------------------------------------------------------------------------------|
| <span> <span style="font-size: 16px;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) </span> |
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{5}------------------------------------------------
K173260 - page 1 of 4
Image /page/5/Picture/2 description: The image contains the logo for SeaSpine. The logo consists of a stylized wave graphic in shades of blue and gray, followed by the word "SeaSpine" in orange. A gray line is located underneath the word "SeaSpine".
### 510(k) Summary
K173260
### Contact Details
| Applicant Name: | SeaSpine Orthopedics Corporation |
|-----------------|----------------------------------------|
| Address: | 5770 Armada Drive, Carlsbad CA |
| Phone number: | (760) 216-5136 |
| Fax number: | (760) 683-6874 |
| Contact person: | Gina Flores, Sr. Regulatory Specialist |
| Email address: | gina.flores @ seaspine.com |
| Date Prepared: | October 24, 2017 |
# Device Name
| | Trade Name | Common<br>Name | Classification<br>Name | Class | Product<br>Code |
|---|--------------------------------------------------------------------------------------|------------------------------------------------------------|----------------------------------------------------------------------|----------|-----------------|
| 1 | SeaSpine Spacer System (NanoMetalene)-<br>Hollywood, Hollywood VI, Ventura, Pacifica | Intervertebral Fusion<br>Device with Bone<br>Graft, Lumbar | Intervertebral Body Fusion<br>Device (21 CFR 888.3080) | Class II | MAX |
| 2 | SeaSpine Spacer System -<br>Hollywood, Hollywood VI, Ventura, Pacifica | Intervertebral Fusion<br>Device with Bone<br>Graft, Lumbar | Intervertebral Body Fusion<br>Device (21 CFR 888.3080) | Class II | MAX |
| | | Spinal Vertebral Body<br>Replacement Device | Spinal Intervertebral Body<br>Fixation Orthosis (21 CFR<br>888.3060) | | MQP |
| 3 | SeaSpine Vu e-POD System | Intervertebral Fusion<br>Device with Bone<br>Graft, Lumbar | Intervertebral Body Fusion<br>Device (21 CFR 888.3080) | Class II | MAX |
| | | Spinal Vertebral Body<br>Replacement Device | Spinal Intervertebral Body<br>Fixation Orthosis (21 CFR<br>888.3060) | | MQP |
### Legally Marketed Predicate Devices
- 1. SeaSpine Spacer System (NanoMetalene)-Hollywood, Hollywood VI, Ventura, Pacifica:
| 510(k) Number | Product Code | Trade Name | Manufacturer |
|---------------------------------|--------------|---------------------------------------------------------------|-------------------------------------|
| PRIMARY PREDICATE Device | | | |
| K162715,<br>K142488,<br>K102026 | MAX | SeaSpine Spacer System<br>Hollywood, Hollywood VI,<br>Ventura | SeaSpine Orthopedics<br>Corporation |
| Additional PREDICATE Devices | | | |
| K162351 | OVD | Vu a•POD Prime<br>NanoMetalene | SeaSpine Orthopedics<br>Corporation |
{6}------------------------------------------------
Image /page/6/Picture/2 description: The image shows the logo for SeaSpine. The logo consists of a stylized wave graphic on the left, followed by the word "SeaSpine" in orange. The wave graphic is made up of three curved lines in shades of blue. A gray line is located underneath the text.
# 2. SeaSpine Spacer System-Hollywood, Hollywood VI, Ventura, Pacifica:
| 510(k) Number | Product Code | Trade Name | Manufacturer |
|------------------------------|--------------|--------------------------------------------------------------------------|-------------------------------------|
| PRIMARY PREDICATE Device | | | |
| K082310 | MQP, MAX | SeaSpine Spacer System:<br>Hollywood, Hollywood VI,<br>Ventura, Pacifica | SeaSpine Orthopedics<br>Corporation |
| Additional PREDICATE Devices | | | |
| K162351 | OVD | Vu a•POD Prime<br>NanoMetalene | SeaSpine Orthopedics<br>Corporation |
- 3. SeaSpine Vu e·POD System:
| 510(k) Number | Product Code | Trade Name | Manufacturer |
|-------------------------------------|--------------|------------------------------------|------------------------------------------------------------------------------------|
| <b>PRIMARY PREDICATE Device</b> | | | |
| K082712 | MQP, MAX | SeaSpine Vu e-POD System<br>(PEEK) | SeaSpine Orthopedics<br>Corporation<br>(originally manufactured<br>by Theken, LLC) |
| <b>Additional PREDICATE Devices</b> | | | |
| K162351 | OVD | Vu a•POD Prime<br>NanoMetalene | SeaSpine Orthopedics<br>Corporation |
{7}------------------------------------------------
### Device Description
The SeaSpine Spacer System (Hollywood, Hollywood VI, Ventura, Pacifica), and Vu e-POD, are intervertebral fusion devices intended to promote spinal fusion by acting as a disc spacer and holding autograft bone graft and/or allogeneic bone graft composed of cancellous and /or corticocancellous bone. The implants have teeth on the superior and inferior surfaces and a central canal for receiving the autograft. The devices are available in a variety of shapes, lengths, widths, and heights to accommodate variations in pathology and patient anatomy. All implants are manufactured from PEEK (per ASTM F2026) with radiographic markers manufactured from tantalum (per ASTM F560). The implants are offered either in all PEEK (ASTM F2026) or coated with commercially pure titanium (ASTM F67), NanoMetalene.
The NanoMetalene spacers are provided in gamma sterilized packaging, while the PEEK spacers are provided non-sterile for subsequent sterilization at the healthcare facility.
The instruments included with each system facilitate the placement and adjustment of the interbody spacers, and removal if necessary. The instruments are placed in trays and caddies for storage, protection, and organization prior to and during the steam sterilization process.
### Intended Use/Indications for use
#### SeaSpine Spacer System (NanoMetalene)- Hollywood, Hollywood VI, Ventura, Pacifica
When used as an intervertebral body fusion device, the system is intended for spinal fusion procedures at one or two contiguous levels (L2-S1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). These patients should have had six months of non-operative treatment. The device is intended to be used with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone and supplemental fixation.
### SeaSpine Spacer System- Hollywood, Hollywood VI, Ventura, Pacifica
When used as an intervertebral body fusion device, the system is intended for spinal fusion procedures at one or two contiguous levels (L2-S1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). These patients should have had six months of non-operative treatment. The device is intended to be used with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone and supplemental fixation.
When used as a vertebral body replacement device (VBR) the SeaSpine Spacer System is intended for use in the thoracolumbar spine (T1 to L5) to replace a collapsed, damaged or unstable complete or partial vertebral body due to tumor or trauma/fracture, to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of a collapsed vertebral body. The SeaSpine Spacer System is designed to restore the biomechanical integrity of the anterior, middle, and posterior spinal column, even in the absence of fusion for a prolonged
{8}------------------------------------------------
Image /page/8/Picture/2 description: The image shows the logo for SeaSpine. The logo consists of a stylized wave graphic on the left, followed by the word "SeaSpine" in orange. The wave graphic is made up of several curved lines in shades of blue and gray, suggesting movement. The overall design is clean and modern.
period. Additionally, the SeaSpine Spacer System is intended for use with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone.
### SeaSpine Vu e·POD System
When used as an intervertebral body fusion device, the Vu ePOD Intervertebral Body Fusion Device is indicated for use as an adjunct to fusion in patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1. These DDD patients may also have up to Grade 1 spondylolisthesis at the involved level(s). The device is indicated for use with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone. The Vu e•POD Intervertebral Body Fusion Devices are intended for use with supplemental fixation.
Degenerative disc disease (DDD) is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had six months of non-operative treatment.
When used as a vertebral body replacement (VBR) the Vu e•POD System is indicated for use in the thoracolumbar spine (TI-L5) to replace a collapsed, damaged or otherwise unstable vertebral body due to tumor or trauma (i.e. fracture). The Vu e•POD VBR System is designed to restore the biomechanical integrity of the anterior, middle and posterior spinal column even in the absence of fusion for a prolonged period. The device is indicated for use with autograft bone graft and/or allogeneic bone graft composed of cancellous and/or corticocancellous bone. The Vu ePOD VBR System is intended for use with supplemental internal spinal fixation.
### Summary of Technological Characteristics
The SeaSpine Spacer System (Hollywood, Hollywood VI, Ventura, and Vu e-POD System and the predicate devices have the same operational principle; they act as a disc spacer and hold bone graft to promote fusion in the spine. The SeaSpine Spacer System, and Vu e-POD are substantially equivalent to the cited predicate devices in areas including intended use/indications for use, technological characteristics (operating principle, design, materials, sterility, manufacturing, etc.) and performance (mechanical safety).
### Non-Clinical Testing
There are no changes to the design, materials, specifications or manufacture of the implants, therefore no mechanical testing was performed.
Packaging, shipping and sterilization tests were performed to validate a Sterility Assurance Level (SAL) of 10-6 and ensure maintenance of a sterile barrier. Bacterial Endotoxin testing (BET) was conducted in accordance with ANSVAAMI ST-72:2011.
### Clinical Testing
Not applicable; determination of substantial equivalence is not based on an assessment of clinical performance data.
### Conclusions
The submitted data demonstrate that the SeaSpine Spacer System (Hollywood, Hollywood VI, Ventura, Pacifica), and Vu e-POD Systems are substantially equivalent to the cited legally marketed predicate devices.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.