K162328 · Winner SG Pte, Ltd. · IOR · May 11, 2017 · Physical Medicine
Device Facts
Record ID
K162328
Device Name
Winner Transfer Wheelchair
Applicant
Winner SG Pte, Ltd.
Product Code
IOR · Physical Medicine
Decision Date
May 11, 2017
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3850
Device Class
Class 1
Attributes
Therapeutic
Indications for Use
The Winner Transfer Wheelchair is a manually operated wheelchair that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
Device Story
Manually operated wheelchair for mobility-restricted individuals; used in healthcare settings or home environments. Propelled by user or assistant. Features aluminum frame, adjustable armrests, upholstered back, and removable footrests. Includes Kingfisher 125T Retractable Kit accessory allowing rear wheel linear retraction to facilitate lateral transfers using transfer boards. Wheel retraction occurs only when stationary, not during operation. Provides mobility and assists in patient transfers; improves ease of lateral transfer compared to standard wheelchairs.
Clinical Evidence
No clinical data. Substantial equivalence supported by bench testing per recognized consensus standards including ISO 7176-1, 7176-3, 7176-5, 7176-7, 7176-8, 7176-11, 7176-13, 7176-15, 7176-16, 7176-22, and BS EN 12183.
Technological Characteristics
Manual wheelchair; aluminum frame; polyurethane foam/nylon upholstery; aluminum hand rims. Features Kingfisher 125T Retractable Kit for rear wheel adjustment. Tested to ISO 7176 series (stability, brakes, dimensions, fatigue/impact strength) and BS EN 12183. Foldable design with adjustable/removable legrests and armrests.
Indications for Use
Indicated for persons restricted to a sitting position who require mobility assistance due to difficulty or inability to walk.
Regulatory Classification
Identification
A mechanical wheelchair is a manually operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which features a staff with a serpent entwined around it, overlaid with three human profiles facing to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the symbol.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
May 11, 2017
Winner Sg Pte Ltd % Diane Horwitz, Ph.D., RAC Regulatory Consultant Eminence Clinical Research, Inc. 1880 Office Club Pointe. Suite 1360 Colorado Springs, Colorado 80920
Re: K162328
Trade/Device Name: Winner Transfer Wheelchair Regulation Number: 21 CFR 890.3850 Regulation Name: Mechanical Wheelchair Regulatory Class: Class I Product Code: IOR Dated: April 10, 2017 Received: April 12, 2017
Dear Dr. Horwitz:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801 and Part 809); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the
{1}------------------------------------------------
electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and Part 809), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely.
# Michael J. Hoffmann -S
for Carlos L. Peña, PhD, MS Director Division of Neurological and Physical Medicine Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known) K162328
Device Name Winner Transfer Wheelchair
Indications for Use (Describe)
The Winner Transfer Wheelchair is a manually operated wheelchair that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
Type of Use (Select one or both, as applicable)
Prescription Use (Part 21 CFR 801 Subpart D)
|X | Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
#### 1. Submission Sponsor
Winner SG Pte Ltd Michael Pang, Managing Director 14 Little Road #07-01 Tropical Industrial Building Singapore 536987 Email: michael@winner-wheelchair.com.sg Phone: +65 93635453 Owner/Operator Number: 10047779
#### 2. Submission Correspondent
Eminence Clinical Research, Inc. Diane Horwitz, Ph.D., RAC 1880 Office Club Pointe Suite 1360 Colorado Springs, CO 80920 Email: dhorwitz@ecr-inc.com
#### 3. Initial Importer and US Agent
Prius Healthcare USA, LLC Matthew Farrell 4029 Tampa Rd suite 4000c Oldsmar, FL 34677 Phone: 813 8545464 ext. 304 Fax: 813 8545442 Email: mfarrell@priushcusa.com Registration number: 3008546725 Owner/Operator number: 10034069
#### 4. Date Prepared
May 9, 2017
#### 5. Device Identification
Winner Transfer Wheelchair Trade/Proprietary Name: Common/Usual Name: Mechanical Wheelchair Mechanical Wheelchair Classification Name: Classification Regulation: 890.3850 Product Code: IOR Device Class: Class I Physical Medicine Classification Panel:
{4}------------------------------------------------
### 6. Legally Marketed Predicate Device(s)
Breezy Elegance Manual Folding Wheelchair, K133855, Sunrise Medical LLC
#### 7. Device Description
The Winner Transfer Wheelchair is a manual wheelchair used by individuals for whom walking is difficult or impossible and who need assistance in transport. The Winner Transfer Wheelchair is propelled manually by the user propelling the wheels or being pushed by an assistant. The Winner Transfer Wheelchair has the standard attributes of the predicate wheelchair, such as an aluminum frame with flip away, height adjustable and retractable armrests, an adjustable upholstered tension back and flip down back, and a swing away and removable footrest.
The Winner Transfer Wheelchair has an accessory, the Kingfisher 125T Retractable Kit, which can be attached to either the left side or the right side of the Winner Transfer Wheelchair. The Retractable Kit serves to allow the rear wheel to be retracted (moved back in a linear motion), thereby opening the side distance in front of the wheel to permit easier lateral transfer. Whereas in most wheelchairs, the rear wheel is obstructing placement of a Transfer Board which is often used during lateral transfer. When the rear wheel is retracted using the Kingfisher 125T Retractable Kit, it is easier for the user to positioning the transfer board. The base wheelchair can be fitted with a left or right retractable kit.
#### 8. Indication for Use Statement
The Winner Transfer Wheelchair is a manually operated wheelchair that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
#### 9. Substantial Equivalence Discussion
The following table compares the Winner Transfer Wheelchair to the predicate device with respect to intended use, technological characteristics and principles of operation, providing more detailed information regarding the basis for the determination of substantial equivalence.
{5}------------------------------------------------
## Table 1. Comparison of Characteristics
| Manufacturer | Predicate Device<br>Breezy Elegance Manual<br>Folding Wheelchair<br>(K133855)<br>Sunrise Medical | Subject Device<br>Winner Transfer Wheelchair<br>K162328<br>Winner SG G Pte Ltd/<br>A & I Industries | Same or Different<br>(Reason that difference does<br>not impact safety or<br>effectiveness) |
|--------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Product Code | IOR | IOR | Same |
| Regulation Number | 890.3850 | 890.3850 | Same |
| Regulation Name | Mechanical Wheelchair | Mechanical Wheelchair | Same |
| Intended Use /<br>Indications for Use<br>Statement | Breezy Elegance Folding<br>Manual Wheelchairs are<br>manually operated devices<br>with wheels that are intended<br>for medical purposes to<br>provide mobility to persons<br>restricted to a sitting position. | The Winner Transfer Wheelchair is a<br>manually operated wheelchair that<br>is intended for medical purposes to<br>provide mobility to persons<br>restricted to a sitting position. | Similar Intended Use and<br>Indications for Use. Both<br>devices have the same general<br>purpose and both devices are<br>used for subjects with similar<br>mobility with one additional<br>functionality. |
| Use Environment | Healthcare Setting or Home;<br>inside or outside | Healthcare Setting or Home; inside<br>or outside | Same |
| Patients | Individuals who cannot walk<br>for long distances | Individuals who cannot walk for long<br>distances | Same |
| Movement from<br>Wheelchair to Bed or<br>Other Surface | Lateral transfer using transfer<br>board for assistance | Lateral transfer using transfer board<br>for assistance<br>Easier process due to Kingfisher<br>Retractable Kit accessory | Similar but easier transfer with<br>wheel retracted with the<br>Subject Device |
| DIMENSIONS, WEIGHT AND WEIGHT LIMITATION | | | |
| Front Seat to Floor<br>Height | 17 in. (43 cm) expandable to<br>20 in. (51 cm) | 19.7 in. (500 mm) | Similar |
| Front Wheel<br>Diameters | 8 in. x 1.3 in. | 7.9 in. x 2 in. (200 mm x 50 mm) | Similar |
| Rear Wheel<br>Diameters | 24 in. x 1 in. (61 cm x 2.5 cm) | 24 in. x 1 in. (61 cm x 2.5 cm) | Same |
| Seat Width | 16 in. or 18 in. (41 cm or 46<br>cm) | 17.7 in. (450 mm) | Similar |
| User Weight Limit | 275 lbs. (125 kg) | 275 lbs. (125 kg) | Same |
| Chair Weight | 32 lbs. (16 kg) | 39.7 lb. to 52.9 lb. (18 kg to 24 kg),<br>including accessories (retractable<br>wheel(s)) | The retractable wheel<br>accessory weighs 8.4 lb. (3.8<br>kg) |
| Backrest Angle | 80° | 75° | Similar angle; allows for<br>comfortable seating of user |
| MATERIAL | | | |
| Frame Material | Aluminum | Aluminum | Same |
| Upholstery | Polyurethane Foam<br>with Nylon Cover | Polyurethane Foam<br>with Nylon Cover | Same |
| Hand Rims | Aluminum Tubing | Aluminum | Same |
| Manufacturer | Predicate Device<br>Breezy Elegance Manual<br>Folding Wheelchair<br>(K133855)<br>Sunrise Medical | Subject Device<br>Winner Transfer Wheelchair<br>K162328<br>Winner SG G Pte Ltd/<br>A & I Industries | Same or Different<br>(Reason that difference does<br>not impact safety or<br>effectiveness) |
| FEATURES | | | |
| Foldable | Yes | Yes | Same |
| Legrests and<br>Footplates | Adjustable and removable. | Adjustable and removable. | Same |
| Retractable Rear<br>Wheels | Non-retractable | Yes | Difference does not raise<br>safety or effectiveness<br>concerns based on the ISO<br>testing: 7176-1, 7176-8 |
{6}------------------------------------------------
#### 10. Non-Clinical Performance Data
Mechanical Wheelchairs (21 CFR 890.3850, Product Code IOR) have the following applicable guidance document on which this submission was based:
- Guidance Document for the Preparation of Premarket Notification [510k)] Applications for Mechanical and Powered Wheelchairs, and Motorized Three-Wheeled Vehicles, July 26, 1995.
Recognized consensus standards for Product Code IOR, Mechanical Wheelchairs, have been used in the design and testing of the device.
The Winner Transfer Wheelchair with the Kingfisher 125T accessory were tested to and comply with the following listed recognized consensus standards.
- ISO 7176-1:2014 Determination of Static Stability ●
- ISO 7176-3:2012 - Determination of Effectiveness of Brakes
- ISO 7176-5:2008 - Determination of Dimensions, mass and maneuvering space
- ISO 7176-7:1998 Measurement of Seating and Wheel Dimensions ●
- . ISO 7176-11:2012 – Test Dummies
- . BS EN 12183:2014 – Manual Wheelchairs – Requirements and Test Method, with Normative References to the following to demonstrate individual aspects of safety, effectiveness, and substantial equivalence of the Winner Transfer Wheelchair:
- EN 1021-2: 2006, Furniture Assessment of the ignitability of upholstered o furniture - Part 2: Ignition source match flame equivalent and ISO 8191-2.
- ISO 7176-8: 1998, Wheelchairs Part 8: Requirements and test methods for static, o impact and fatigue strengths
- ISO 7176-13: 1989, Wheelchairs Part 13: Determination of coefficient of friction o of test surfaces
- ISO 7176-15: 1996, Wheelchairs Part 15: Requirements for information o disclosure, documentation and labelling
- ISO7176-16: 2012 (Annex A) Resistance to ignition of postural support devices O
- ISO 7176-22: 2000, Wheelchairs Part 22: Set-up procedures O
{7}------------------------------------------------
As part of demonstrating safety and effectiveness of Winner Transfer Wheelchair and in showing substantial equivalence to the predicate devices that are subject to this 510(k) submission, Winner SG Pte Ltd completed performance tests per the International Standards above. The Winner Transfer Wheelchair meets all the requirements for overall design and confirms that the output meets the design inputs and specifications. The Winner Transfer Wheelchair passed all testing stated above as shown by the acceptable results obtained.
## 11. Clinical Performance Data
There was no clinical testing required to support the medical device as the indications for use is equivalent to the predicate device. These types of devices, including the predicate devices, have been on the market for many years with a proven safety and efficacy for the use of the device. The non-clinical testing detailed in this submission supports the substantial equivalence of the device.
## 12. Statement of Substantial Equivalence
By definition, a device is substantially equivalent to a predicate device when the device has the same intended use and the same technological characteristics as the previously cleared predicate device. Technological improvements may add new features, however base technological characteristics should be equivalent and no new questions should be raised regarding its safety and effectiveness.
The Winner Transfer Wheelchair device shares the same base indications for use, device operation, overall technical and functional capabilities as the predicate device, and both the Winner Transfer Wheelchair with the Kingfisher 125T Retractable Kit as well as the predicate device meet product specifications and international performance standards. The addition of the Kingfisher 125T Retractable kit does not present any new issues around safety during wheelchair use, as the wheels are not retracted while the wheelchair is being driven. The Winner Transfer Wheelchair is identical in design and function to the predicate device for the all basic expected modes of operation and use and only differs with the addition of the retractable wheel. As all items are identical with only the added convenience functionality it is concluded that the Winner Transfer Wheelchair is substantially equivalent to the predicate device.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.