The intended use of the I.T.S. Extemity Fixation Systems is to draw two or more aligned bone fragments together to facilitate healing in an adult patient and is composed of the following catagories: The I.T.S. FLS - Foot Locking Plates System is indicated for use in internal fixation, reconstruction or arthrodesis of small bones including the fore, mid and hind foot and ankle. Examples of these procedures may include but are not limited to replantation, lag screw techniques, joint fusions, corrective osteotomies, and treatment of fractures. Not for spinal use. The I.T.S. HCS - Headless Compression Screw System for sizes of 3.5mm or smaller is indicated for use in fixation small bone fractures or for small bone reconstruction including: mono or bicortical osteotomies in the foot or hand; distal or proximal metatarsal or metacarpal osteotomies; weil osteotomy; fusion of the first metatarsalphalangeal joint and interphalageal joint; fixation of osteotomies for Hallux Valgus treatment (such as Scarf, Chevron, etc.); Akin type osteotomy; distal radius fractures (articular fragments), ulnar styloid fractures, radial head fractures, capitellum fractures, humeral head fractures, glenoid fractures, intercarpal distal and proximal fusions, malleolar fractures, patellar fractures, osteochondral fractures, talonavicular fusions, tibeo-talar fusions, and cuboid fusions. And for sizes 4.3mm or larger is indicated for use for fractures, corrective osteotomies, pseudoarthrosis, degenerative transformations of long bones in the hindfoot and large bone intra-articular fractures of the humerus, femur, and tibia. The size of the chosen compression screw should be adapted to the specific indication. Not for spinal use. The I.T.S. HOL - Hallux Osteotomy Locking Plate System is indicated for use as an intramedullary self-locking plate for distal metatarsal osteotomies and for Hallux Valgus osteotomies up to a corrective angle of 250. Not for spinal use. The I.T.S. Twist-Off Screw System is indicated for use for small bone fixation of bone fractures or for bone reconstruction. Examples include small bone fragments, Weil-Osteotomy, Mono-Cortical fixation, Osteotomies and fractures fixation in the foot and hand. Not for spinal use.
Device Story
Extremity fixation system comprising locking plates, headless compression screws, hallux osteotomy plates, and twist-off screws; used for bone fracture stabilization, reconstruction, and arthrodesis. Plates allow intra-operative contouring; screws provide compression across bone fragments. Operated by surgeons in clinical settings; utilizes fluoroscopic imaging for positioning and reduction. System includes ancillary instrumentation (drills, guide wires). Output is mechanical stabilization of bone segments to facilitate healing. Benefits include low-profile design to minimize soft-tissue irritation.
Clinical Evidence
No clinical data provided; substantial equivalence determined via comparison of technological characteristics and intended use to predicate devices.
Indicated for adult patients requiring internal fixation, reconstruction, or arthrodesis of small bones (foot, hand, ankle) and long bones (humerus, femur, tibia). Specific applications include fracture treatment, osteotomies (e.g., Hallux Valgus, Weil), joint fusions, and pseudoarthrosis. Contraindicated for spinal use.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Wright Medical - Charlotte Snap-Off Screws (K050819, K043583)
Submission Summary (Full Text)
{0}------------------------------------------------
I.T.S. GmbH - 510(k) Summary - __
## K131722 page 1 of 4
# 510(k) Summary of Safety and Effectiveness
# SAFE MEDICAL DEVICES ACT OF 1990
510(k) Summary
| NAME OF FIRM: | I.T.S. GmbH<br>Autal 28<br>Lassnitzhöehe A – 8301<br>AUSTRIA<br>www.its-implant.com | |
|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|
| 510(k) FIRM CONTACT: | Al Lippincott<br>Engineering Consulting Services, Inc.<br>3150 E. 200th St.<br>Prior Lake, MN 55372<br>Tel. No. 952-492-5858<br>e-mail: allippincott@msn.com | AUG 07 2013 |
| DATE: | June 10, 2013 | |
| TRADE NAME: | I.T.S. Extremity Fixation Systems | |
| COMMON NAME: | Bone Plate, Bone Screw, Compression Screw - Systems | |
| CLASSIFICATION: | Plate, Fixation, Bone & Screw, Fixation, Bone | |
| | Smooth or threaded metallic bone fixation appliances and<br>accessories. (see 21 CRF, Sec. 888.3030)<br>Smooth or threaded metallic bone fixation fastener,<br>(see 21CFR, Sec. 888.3040). | |
#### DEVICE PRODUCT CODE:
## HRS
HWC
SUBSEQUENT PRODUCT CODE:
SUBSTANTIALLY EQUIVALENT DEVICES Ortho Solutions - Extremity Fixation Implants (K111678) Stryker - Foot Plating Systems (K060613, K063875) Memometal - Anchorage Bone Plate System (K083447) Smith & Nephew - VLP Variable-Angle System (K090675) Synthes - 2.4/2.7mm Variable Angle (VA)-LCP Forefoot / Midfoot System (K100776) Vilex - Cannulated Dual Thread Screws (K014154) Memometal - FIXOS Compression Screws (K070039) Merete Medical - Cannulated HCS Compression Screws (K091798) Integra - QWIX Fixation Screws (K071639) Arthrex - Low Profile Plate and Screw System (K052614) SBI - ForeFIX II (K071479) Biomet - BioDrive Micro Nail Plate (K092670) Memometal - FIXOS Twist-Off Screw (K070039) Wright Medical - Charlotte Snap-Off Screws (K050819, K043583)
I.T.S. Extremity Fixation Systems
Page 1 of 4
,
{1}------------------------------------------------
# K131722 page 2 of 4
### 1.T.S. GmbH - 510(k) Summary: DEVICE DESCRIPTION:
The I.T.S. Extremity Fixation Systems consists of Predicate extremity trauma implant components commonly found with large companies with orthopedic markets in the United States. These 'extremity trauma implant devices' consist of the following categories:
1. FLS - Foot Locking Plates System
2. HCS - Headless Compression Screw System
#### 3. HOL- Hallux Osteotomy Locking Plate
### 4. Twist-Off Screws
A brief and concise description of each system is enclosed as follows:
1. FLS - Foot Locking Plates System: The I.T.S. FLS - Foot Locking Plates System is composed of various plate types(13) designed to address a wide variety of indications for fractures in the foot. The overall system is composed of a smaller bone series of locking plates (12 types) utilizing 2.4mm, 2.7mm and 3.0mm locking/non-locking screws and a larger bone calcaneus plate utilizing 3.5mm and 4.2mm locking/non-locking screws. The smaller bone system of twelve(12) plate designs consist of the following: (1) MTP Plate, (2) Curved Plate, (3) Straight Plate, (4) H-Shape Plate, (5) Square Plate, (6) I -- Shape Plate, (7) L-Shape Extended Plate, (8) L-Shape Extended, 1mm Step Plate, (9) L-Shape Extended 45º Plate, (10) T-Shape Plate, (11) T-Shape Extended Plate, and (12) TMT Plate. The larger bone system consists of a (13) Calcaneus Plate. All plate systems are manufactured from Commercially Pure (CP) Titanium material to ASTM F67 and allow for minor intra-operative forming/ contouring by the surgeon to fit the bone anatomy. All screws consist of 6-4 Alloyed Titanium material to ASTM F136. Small holes in the plate allow intermediate 'k-wire' bone fracture segment positioning for reducing and aligning the fracture bone segments while positioning the plate and introduction of multiple sizes of locking/non-locking screws as needed for stabilizing the fracture - when using x-ray fluroscopy. All I.T.S. Plates and Screws are processed with an anodize DOTIZE surface treatment. The low-profile and contoured plate design minimizes soft-tissue irritation for the patient.
Associated instrumentation such as disposable drills, mills & wires/guide wires, and ancillary instrumentation is available. All plates and screws are provided Non-Sterile.
I.T.S. Extremity Fixation Systems
Section XII
{2}------------------------------------------------
### 1.T.S. GmbH - 510(k) Summary: DEVICE DESCRIPTION CONTINUED:
## K131722 page 3 of 4
HCS - Headless Compression Screw System: The I.T.S. 2. HCS - Headless Compression Screw System consists of six(6) sizes of compression screws (in sizes 2.0, 2.5, 3.0, 3.5, 4.3 and large/long bone 7.5mm) for small bone extremity and reconstruction fixation/arthrodesis procedures. All screws consist of a 6-4 Alloyed Titanium material to ASTM F136. All I.T.S. Compression Screws are processed with an anodize DOTIZE surface-treatment.
Associated instrumentation such as disposable wires/guide wires, cannulated spiral drills, countersink drills, and ancillary instrumentation is available. All screws are provided Non-Sterile.
3. HOL - Hallux Osteotomy Locking Plate: The I.T.S. HOL -Hallux Osteotomy Locking Plate consists of a Nail Plate in three(3) sizes with Screws in various lengths for Halux and distal metatarsal foot/toe bone deformities. The Nail Plate is manufactured from CP Titanium to ASTM F67 and the Screws from 6-4 Alloyed Titanium to ASTM F136. All I.T.S. Nail Plate and Screws are processed with an anodize DOTIZE surface treatment.
Associated instrumentation such as guide wire, disposable drill, template, insertion/removal and ancillary instrumentation is available. All Plates and Screws are provided Non-Sterile.
4. Twist-Off Screws: The I.T.S. Twist-Off Screws consist of a 2.0mm and 2.7mm twist-off shank screws in various lengths. All Turn-Off Screws are manufactured from 6-4 Alloyed Titanium to ASTM F136 and are utilized in metatarsal/phalangeal small bone fixation/osteotomy procedures. All I.T.S. Twist-Off Screws are processed with an anodize DOTIZE surface treatment. All Screws are provided Non-sterile.
INTENDED USE:
The intended use of the I.T.S. Extemity Fixation Systems is to draw two or more aligned bone fragments together to facilitate healing in an adult patient and is composed of the following catagories:
The I.T.S. FLS - Foot Locking Plates System is indicated for use in internal fixation, reconstruction or arthrodesis of small bones including the fore, mid and hind foot and ankle. Examples of these procedures may include but are not limited to replantation, lag screw techniques, joint fusions, corrective osteotomies, and treatment of fractures. Not for spinal use.
1.T.S. Extremity Fixation Systems
{3}------------------------------------------------
#### I.T.S. GmbH - 510(k) Summary: INTENDED USE CONTINUED:
The I.T.S. HCS - Headless Compression Screw System for sizes of 3.5mm or smaller is indicated for use in fixation small bone fractures or for small bone reconstruction including: mono or bicortical osteotomies in the foot or hand; distal or proximal metatarsal or metacarpal osteotomies; weil osteotomy; fusion of the first metatarsalphalangeal joint and interphalageal joint; fixation of osteotomies for Hallux Valgus treatment (such as Scarf, Chevron, etc.); Akin type osteotomy; distal radius fractures (articular fragments), ulnar styloid fractures, radial head fractures, capitellum fractures, humeral head fractures, glenoid fractures, intercarpal distal and proximal fusions, malleolar fractures, patellar fractures, osteochondral fractures, talonavicular fusions, tibeo-talar fusions, and cuboid fusions. And for sizes 4.3mm or larger is indicated for use for fractures, corrective osteotomies, pseudoarthrosis, degenerative transformations of long bones in the hindfoot and large bone intra-articular fractures of the humerus, femur, and tibia. The size of the chosen compression screw should be adapted to the specific indication. Not for spinal use.
The I.T.S. HOL - Hallux Osteotomy Locking Plate System is indicated for use as an intramedullary self-locking plate for distal metatarsal osteotomies and for Hallux Valgus osteotomies up to a corrective angle of 250. Not for spinal use.
The I.T.S. Twist-Off Screw System is indicated for use for small bone fixation of bone fractures or for bone reconstruction. Examples include small bone fragments, Weil-Osteotomy, Mono-Cortical fixation, Osteotomies and fractures fixation in the foot and hand. Not for spinal use.
The I.T.S. Extremity Fixation Systems are substantially equivalent EQUIVALENCE: to the varoius predicate bone plate and screw systems as listed. No nonclinical testing was used in the determination of substantial equivalence.
SUMMARY OF TECH-NOLOGICAL CHAR-ACTERISTICS
SUMMARY OF SAFETY
The I.T.S. Extremity Fixation Systems are Similar in Material, Geometry Design/Markings, and Indications to predicate system(s) currently sold in the U.S. market.
The I.T.S. Extremity Fixation Systems are shown to be safe and AND EFFECTIVENESS: effective for use in plate and screw fracture fixation of small bones in the foot and hand extremities and screw compression fractures in long/large bones.
#### I.T.S. Extremity Fixation Systems
Section XII
{4}------------------------------------------------
Image /page/4/Picture/12 description: The image shows the seal of the Department of Health & Human Services (USA). The seal features a stylized eagle with three tail feathers, representing the department's commitment to health, services, and human needs. The eagle is encircled by the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement.
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
August 7, 2013
I.T.S. GmbH % Engineering Consulting Services. Incorporated Mr. Al Lippincott United States Agent and Official Correspondent to I.T.S. GmbH 3150 East 20010 Street Prior Lake, Minnesota 55372
Re: K131722
Trade/Device Name; I.T.S. Extremity Fixation Systems Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: Class II Product Code: HRS. HWC Dated: June 26, 2013 Received: June 28, 2013
Dear Mr. Lippincott:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the cnactment date of the Medical Device Amendments, or 10 devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complics with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21
{5}------------------------------------------------
Page 2 - Mr. Al Lippincott
CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling reculation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
# Erin I. Keith
For
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
# INDICATIONS FOR USE
# 510(k) NUMBER: __K131722
# DEVICE NAME: I.T.S. Extremity Fixation Systems
The intended use of the I.T.S. Externity Fixation Systems is to draw two or more aligned bone fragments together to facilitate healing in an adult patient and is composed of the following catagories:
The I.T.S. FLS - Foot Locking Plates System is indicated for use in internal fixation, reconstruction or arthrodesis of small bones including the fore, mid and hind foot and ankle. Examples of these procedures may include but are not limited to replantation, lag screw techniques, joint fusions, corrective osteotomies, and treatment of fractures. Not for spinal use.
The I.T.S. HCS - Headless Compression Screw System for sizes of 3.5mm or smaller is indicated for use in fixation small bone fractures or for small bone reconstruction including; mono or bicortical osteotomies in the foot or hand; distal or proximal metatarsal or metacarpal osteotomies; weil osteotomy; fusion of the first metatarsalphalangeal joint and interphalageal joint; fixation of osteotomies for Hallux Valgus treatment (such as Scarf, Chevron, etc.); Akin type osteotomy; distal radius fractures (articular fragments), ulnar styloid fractures, radial head fractures, capitellum fractures, humeral head fractures, glenoid fractures, intercarpal distal and proximal fusions, malleolar fractures, patellar fractures, osteochondral fractures, talonavicular fusions, tibeo-talar fusions, and cuboid fusions.
And for sizes 4.3mm or larger is indicated for use for fractures, corrective osteotomies, pseudoarthrosis, degeneralive transformations of long bones in the hindfoot and large bone intra-articular fractures of the humerus, femur, and tibia. The size of the chosen compression screw should be adapted to the specific indication. Not for spinal use
The I.T.S. HOL – Hallyx Osteotomy Locking Plate System is indicated for use as an intramedullary self-locking plate for distal metatarsal osteotomies and for Hallux Valgus osteotomies up to a corrective angle of 25°. Not for spinal use.
The I.T.S. Twist-Off Screw System is indicated for use for small bone fixation of bone fractures or for bone reconstruction. Examples include small bone fragments, Weil-Osteotomy, Mono-Cortical fixation, Osteotomies and fractures fixation in the foot and hand. Not for spinal use.
Prescription Use XXXXX Over-The-Counter-Use _________________________________________________________________________________________________________________________________________________________
=
(Per 21 CFR 801 Subpart D)
(21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
AND/OR
Concurrence of CDRH, Office of Device Evaluation (ODE)
Elizabeth L. Frank -S
Division of Orthopedic Devices
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.