K063558 · Ultradent Products, Inc. · KLE · Dec 14, 2006 · Dental
Device Facts
Record ID
K063558
Device Name
PEAK SE, MODEL 5135
Applicant
Ultradent Products, Inc.
Product Code
KLE · Dental
Decision Date
Dec 14, 2006
Decision
SESE
Submission Type
Special
Regulation
21 CFR 872.3200
Device Class
Class 2
Indications for Use
For use in most light-accessible bonding procedures in both the anterior and posterior. Peak™ SE is used with Peak™ Bond Adhesive for dentin, enamel porcelain and composite bonding.
Device Story
Peak™ SE is a syringe-delivered, self-etching primer component of the Peak™ Resin Bonding System. It utilizes a MixSyr (syringe-in-syringe) delivery mechanism to ensure fresh chemistry for every procedure. Used by dental professionals in clinical settings for restorative dentistry, it is applied to dentin, enamel, porcelain, metal, and composite surfaces. The device is designed to be used in conjunction with Peak™ Bond Adhesive and is compatible with high-intensity curing lights, including LEDs. By eliminating the need for a separate etching step, the system simplifies the bonding process, potentially improving clinical efficiency while providing radiopaque, filled bonding material for light-accessible anterior and posterior procedures.
Clinical Evidence
Bench testing only. Comparative studies performed against predicate devices (PermaQuick™ SE and Clearfil SE) evaluating biocompatibility, safety, physical properties, ease of use, ingredients, radiopacity, shrinkage, and bond strength. Results indicated that Peak™ SE met or exceeded testing expectations.
Technological Characteristics
Syringe-delivered, self-etching primer; 7.5% filled and radiopaque; MixSyr (syringe-in-syringe) delivery system; light-cured; compatible with high-intensity lights/LEDs.
Indications for Use
Indicated for restorative dentistry bonding needs. Bonds chemical cure luting and chemical cure composites (e.g., PermaFlo DC). Suitable for bonding to dentin, enamel, porcelain, metal, and composite. Does not require separate etching step.
Regulatory Classification
Identification
A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted on the interior of a prepared cavity of a tooth to improve retention of a restoration, such as a filling.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for Ultradent Products, Inc. The logo features a stylized "U" and "a" to the left of the word "ULTRADENT" in a bold, sans-serif font. Below "ULTRADENT" is the text "PRODUCTS, INC." in a smaller, thinner font. The logo is black and white.
K063558
# SPECIAL 510(K) PREMARKET SUMMARY
## Peak™ SE
DEC 1 4 - 3
This summary of the Special 510(k) substantial equivalence information is being submitted in accordance with the requirements of 21 CFR 807 for Peak™ SE.
Applicant's Name and Address:
Ultradent Products, Inc. 505 West 10200 South South Jordan, UT 84095
Telephone Number: Fax Number: Contact Person: Date Summary Prepared (801) 553-4491 (801) 553-4609 Diane Rogers, R/A Product Specialist November 20, 2006
#### Name of the Device:
Trade name: Common Name: Classification Name: Risk Class: Classification Product Code: Peak™ SE SE Resin Bonding System Resin Tooth Bonding Agent II, (21 CFR 872.3200) 76KLE
#### Legally Marketed Predicate Devices to which Equivalence is Claimed:
PermaQuickTM SE Bonding System K032626 Manufactured and distributed by Ultradent Products, Inc. 505 West 10200 South, South Jordan, Utah 84095.
#### Clearfil SE Bond K990040
Manufactured and Distributed by Kuraray America Inc. 101 East 52nd Street, 26th Floor New York, NY 10122
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image contains the logo for Ultradent Products, Inc. The logo features a stylized "U" and "D" on the left, followed by the word "ULTRADENT" in bold, uppercase letters. Below "ULTRADENT" is the phrase "PRODUCTS, INC." in a smaller, sans-serif font.
## Device Description and Performance Characteristics:
Peak TM SE Bonding System is a syringe delivered self-etching primer component of the PeakTM Resin Bonding System.
### Intended Use:
For use in most light-accessible bonding procedures in both the anterior and posterior. Peak™ SE is used with Peak™ Bond Adhesive for dentin, enamel porcelain and composite bonding.
## Technological Characteristics:
Peak™ SE is a syringe delivered self-etching primer component of the Peak™ Resin Bonding System. Our unique MixSyr delivery (syringe-in-syringe) ensures a fresh mix of chemistry for every procedure. Peak™ SE is to be used specifically with our syringe delivered, light cured bonding agent. PeakTM Bond. Peak™ SE is 7.5% filled and radiopaque. The system will cure with most high intensity lights including LEDs.
## Brief Description of Testing Performed and Conclusion:
Peak TM SE was designed, tested and compared to its predicates, PermaQuick™ SE, Ultradent Products, Inc. and Clearfil SE, Kuraray Co. Ltd. in the following categories: Intended Use, Description, Biocompatibility and Safety, Properties, Ease of Use, Ingredients, Radiopacity, Shrinkage and Bond Strength. All of our testing concluded that Peak™ SE has met or exceeded our testing expectations.
#### Substantial Equivalence
In conclusion, Peak™ SE, that is to be manufactured and marketed by Ultradent Products, Inc., 505 West 10200 South, South Jordan, Utah 84095, is substantially equivalent to our PermaQuick™ SE which has the same intended use, and are equally safe for the indications as described. Please feel free to contact me for further explanation and dialogue with respect to this product, as it is my understanding that the product is substantially equivalent to products
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the logo for Ultradent Products, Inc. The logo features a stylized "U" on the left, followed by the word "ULTRADENT" in bold, uppercase letters. Below "ULTRADENT" is the phrase "PRODUCTS, INC." in a smaller, thinner font. The overall design is simple and professional.
Image /page/2/Picture/1 description: The image shows a black and white photograph of a rocky landscape. The top portion of the image shows a large rock formation with a dark, shadowed area beneath it. The bottom portion of the image shows a more textured, possibly grassy or rocky area. There are two white circles in the image, one in the shadowed area of the rock formation and one in the textured area.
legally marketed for this indication. I can be reached for discussion at the number listed above and would appreciate the opportunity to further clarify as necessary.
Diane Rogers
Regulatory Affairs Product Specialist
November 20, 2006
Date
{3}------------------------------------------------
Image /page/3/Picture/10 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized caduceus, which is a symbol often associated with medicine and healthcare. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" are arranged in a circular pattern around the caduceus.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Ms. Diane Rogers Regulatory Affairs Product Specialist Ultradent Products, Incorporated 505 West 10200 South South Jordan, Utah 84095
DEC 1 4 2006
Re: K063558 Trade/Device Name: Peak™ SE Regulation Number: 21 CFR 872.3200 Regulation Name: Resin Tooth Bonding Agent Regulatory Class: II Product Code: KLE Dated: November 21, 2006 Received: December 08, 2006
Dear Ms. Rogers:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2 - Ms. Diane Rogers
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Chih-S. Liu, Ph.D.
Chiu S. Lin, PhD Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Indications for Use
## 510(k) Number (if known): K063557
Device Name: Peak™ SE
### Indications for Use:
Use for most bonding needs in restorative dentistry. Bonds chemical cure luting and chemical cure composites, namely PermaFlo DC. Peak SE does not require a separate etching step for quality adhesion. Peak SE is also conducive for bonding to:
- Dentin and enamel o
- Porcelain 0
- o Metal
- Composite o
Prescription Use _ × (21 CFR Part 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR Part 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Susan Runpe
rent problem Grand Con . Connol, Denel Dovices
K063538
Page 1 of ____________________________________________________________________________________________________________________________________________________________________
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.