K061140 · Varian Medical Systems · IYE · May 15, 2006 · Radiology
Device Facts
Record ID
K061140
Device Name
TRILOGY RADIOTHERAPY DELIVERY SYSTEM
Applicant
Varian Medical Systems
Product Code
IYE · Radiology
Decision Date
May 15, 2006
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.5050
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Trilogy™ Radiotherapy Delivery and the Trilogy Tx is intended to provide stereotactic radiosurgery and precision radiotherapy for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated.
Device Story
Trilogy Radiotherapy Delivery System and Trilogy Tx are dual-energy, high dose rate medical linear accelerators. Devices deliver megavoltage x-ray treatments for 3D conformal radiotherapy, intensity-modulated radiotherapy (IMRT), and stereotactic radiosurgery (SRS). Inputs include treatment planning data; system transforms inputs into precise radiation delivery via gantry-mounted accelerator. Outputs are ionizing radiation beams directed at lesions, tumors, or conditions. Used in clinical settings by radiation oncologists and medical physicists. System supports intracranial and extracranial treatments, including single-session or fractionated delivery. Provides precision targeting for lesions such as arteriovenous malformations, primary tumors, and metastases. Benefits include high-precision dose delivery to target volumes while sparing surrounding healthy tissue.
Clinical Evidence
No clinical data provided; substantial equivalence is based on technological characteristics, design, and operational parameters compared to legally marketed predicate devices.
Technological Characteristics
Dual-energy medical linear accelerator; energy range 4-25MV. Dose rates up to 600MU/min (3DCRT/IMRT) and 1000MU/min (SRS). Isocenter accuracy ≤1.5mm for all three rotational axes. Maximum field sizes: 40cm x 40cm (3DCRT), 34cm x 40cm (IMRT), 15cm x 15cm (SRS). Features remote couch motion for corrective (≤2cm and 2°) and planned rotations with secondary position readout verification.
Indications for Use
Indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated.
Regulatory Classification
Identification
A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.
{0}
MAY 15 2006
Ko6140 Page 1 of 4
# VARIAN
## medical systems
Varian Medical Systems, Inc.
3100 Hansen Way
Palo Alto, CA 94304-1038
USA
tel +1 650 493 4000
www.varian.com
## 510(k) Summary
The following information is provided following the format of 21 CFR 807.92 for the Trilogy Radiotherapy Delivery System
1. Submitter:
Varian Medical Systems
3100 Hansen Way M/S H055
Palo Alto, CA 94304-1129
Contact Name: Vy Tran
Phone: (650) 424-5731
Fax: (650) 842-5040
Email: vy.tran@varian.com
Date summary was prepared: April 21, 2006
2. Name of the Device:
Trilogy Radiotherapy Delivery System and Trilogy Tx
Trade/Proprietary Name: Trilogy Radiotherapy Delivery System
Common or Usual Name: Trilogy system
Classification Name:
Medical Charged Particle Radiation Therapy System
21 CFR §892.5050
Class II
Product Code: 90 IYE
3. Predicate Devices to claim substantial equivalence:
a. Varian Medical Systems’ Trilogy Radiotherapy Delivery System – K033343
b. Accuray’s CyberKnife - K041315
4. Description of the Device: The Trilogy™ Radiotherapy Delivery System, K033343, is a dual-energy, high dose rate medical linear accelerator optimized for 3D conformal radiation therapy, intensity-modulated radiation therapy and stereotactic applications. The Trilogy system allows for stereotactic treatments that may be intracranial or extracranial and consist of single-session or multi-session (“fractionated”) treatment delivery.
5. Intended Use Statement: The Trilogy™ Radiotherapy Delivery and the Trilogy Tx is intended to provide stereotactic radiosurgery and precision radiotherapy for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated.
6. Substantial Equivalence – The Trilogy Radiotherapy Delivery is substantially equivalent to the predicate devices. The intended use, principles of operation, and technological characteristics are the same.
{1}
Page 2 of 4
# Substantial Equivalence Comparison Chart
The Trilogy™ Radiotherapy Delivery System and the Trilogy Tx Delivery System are substantially equivalent to the CyberKnife® System, K041315 for Intended Use and Indications for Use and are substantially equivalent to the Trilogy™ Radiotherapy Delivery System K033343 for features, design and operation.
The revised Intended Use and Indications for Use statements are equivalent to those used by CyberKnife.
| | CyberKnife® System for Stereotactic Radiosurgery/Radiotherapy, K041315 | Trilogy™ Radiotherapy Delivery System, K033343 | Trilogy™ Radiotherapy Delivery System | Trilogy Tx Delivery System |
| --- | --- | --- | --- | --- |
| Intended Use | The CyberKnife System for Stereotactic Radiosurgery/Radiotherapy is intended to provide treatment planning and image-guided stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated. | The Trilogy™ Radiotherapy Delivery System is a radiation therapy accelerator intended to deliver megavoltage x-ray treatments for conventional radiotherapy (three dimensional conformal radiotherapy and intensity modulated radiotherapy) and stereotactic radiosurgery and radiotherapy. Stereotactic treatments are intended for therapy of lesions, e.g., arteriovenous | The Trilogy™ Radiotherapy Delivery System is intended to provide stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated. | The Trilogy Tx Delivery System is intended to provide stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated. |
{2}
Page 3 of 4
| | | malformations, primary tumors and metastases. Stereotactic treatments may be intracranial or extracranial and consist of single-session or fractionated delivery. | | |
| --- | --- | --- | --- | --- |
| Indications for Use | The CyberKnife System for Stereotactic Radiosurgery/Radiotherapy is indicated for treatment planning and image-guided stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated. | The Trilogy™ Radiotherapy Delivery System is a radiation therapy accelerator intended to deliver megavoltage x-ray treatments for conventional radiotherapy (three dimensional conformal radiotherapy and intensity modulated radiotherapy) and stereotactic radiosurgery and radiotherapy. Stereotactic treatments are intended for therapy of lesions, e.g., arteriovenous malformations, primary tumors and metastases. Stereotactic treatments may be intracranial or extracranial and consist | The Trilogy™ Radiotherapy Delivery System is indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated. | The Trilogy Tx Delivery System is indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated. |
{3}
Page 4 of 4
| | | of single-session or fractionated delivery. | | |
| --- | --- | --- | --- | --- |
| Isocenter | Not Applicable | ≤1.5mm for all three rotational axes | ≤1.5mm for all three rotational axes | ≤1.5mm for all three rotational axes |
| Energy used | Not Applicable | 4-25MV | 4-25MV | 4-25MV |
| Dose rate | Not Applicable | 3DCRT and IMRT: Up to 600MU/min. SRS: Up to 1000MU/min | 3DCRT and IMRT: Up to 600MU/min. SRS: Up to 1000MU/min | 3DCRT and IMRT: Up to 600MU/min. SRS: Up to 1000MU/min |
| Maximum field size | Not Applicable | 3DCRT: 40cm x 40cm. IMRT: 34cm x 40cm. SRS: 15cm x 15cm | 3DCRT: 40cm x 40cm. IMRT: 34cm x 40cm. SRS: 15cm x 15cm | 3DCRT: 40cm x 40cm. IMRT: 34cm x 40cm. SRS: 15cm x 15cm |
| Remote couch motion | Not Applicable | Small, corrective motions (≤2cm and 2°) and large, planned rotations. Secondary position readout indicators perform secondary verification. | Small, corrective motions (≤2cm and 2°) and large, planned rotations. Secondary position readout indicators perform secondary verification. | Small, corrective motions (≤2cm and 2°) and large, planned rotations. Secondary position readout indicators perform secondary verification. |
{4}
DEPARTMENT OF HEALTH & HUMAN SERVICES
Food and Drug Administration
9200 Corporate Blvd.
Rockville MD 20850
MAY 15 2006
Ms. Vy Tran
Corporate Director, Regulatory Affairs
Varian Medical Systems, Inc.
3100 Hansen Way
PALO ALTO CA 94304-1038
Re: K061140
Trade/Device Name: Trilogy Radiotherapy Delivery System and Trilogy Tx Delivery System
Regulation Number: 21 CFR 892.5050
Regulation Name: Medical charged-particle radiation therapy system
Regulatory Class: II
Product Code: IYE
Dated: April 20, 2006
Received: April 25, 2006
Dear Ms. Tran:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
FDA
Protecting and Promoting Public Health
{5}
Please be advised that FDA’s issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act’s requirements, including, but not limited to registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:
| 21 CFR 876.xxxx | (Gastroenterology/Renal/Urology) | 240-276-0115 |
| --- | --- | --- |
| 21 CFR 884.xxxx | (Obstetrics/Gynecology) | 240-276-0115 |
| 21 CFR 892.xxxx | (Radiology) | 240-276-0120 |
| Other | | 240-276-0100 |
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html
Sincerely yours,
Nancy C. Brogdon
Director, Division of Reproductive, Abdominal, and Radiological Devices
Office of Device Evaluation
Center for Devices and Radiological Health
Enclosure
{6}
PAGE 1 of 1
510(k) Number (if known): K061140
Device Name: Trilogy Radiotherapy Delivery System and Trilogy Tx Delivery System
Indications For Use:
The Trilogy™ Radiotherapy Delivery System and Trilogy Tx Delivery System are indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body when radiation treatment is indicated.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Davison Sign-Off
Division of Reproductive, Abdominal, and Radiological Devices
510(k) Number K061140
Prescription Use
(Per 21 CFR 801.109)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.