K023005 · Haywood Vocational Opportunities · IOR · Oct 18, 2002 · Physical Medicine
Device Facts
Record ID
K023005
Device Name
AQUILLA MODULAR WHEELCHAIR
Applicant
Haywood Vocational Opportunities
Product Code
IOR · Physical Medicine
Decision Date
Oct 18, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3850
Device Class
Class 1
Attributes
Pediatric
Indications for Use
The Aquilla Modular Wheelchair is intended to provide mobility for occupants who are unable to walk or have difficulty in walking without assistance.
Device Story
Manually operated wheelchair; provides mobility for occupants unable to walk. Components include backrest, folding seat frame, footrest, rear wheels, front castors, and positioning belts. Configurable for attendant or occupant propulsion. Foldable for storage; removable armrests/footrests. Used in public access environments; operated by occupant or attendant. Benefits include improved mobility and accessibility for users with walking difficulties.
Clinical Evidence
Bench testing only. Device met ISO 7176-1, -3, -5, -7, -8, -15, -16, -19 requirements.
Technological Characteristics
Manual wheelchair; folding frame; adjustable configuration. Components: backrest, seat frame, footrests, wheels, castors, positioning belts. Tested to ISO 7176 series (1, 3, 5, 7, 8, 15, 16, 19).
Indications for Use
Indicated for individuals, junior to adult, male or female, who are unable to walk or have difficulty walking without assistance. Suitable for indoor and outdoor use on public access surfaces. Not for soft/undulating terrain or climbing obstacles.
Regulatory Classification
Identification
A mechanical wheelchair is a manually operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.
{0}------------------------------------------------
### 510(k) SUMMARY 9.
# 09/04/02
### 9.1 Submitter's Name and Contact Information
Submitter Company: Bell, Boyd & Lloyd, LLC 70 W. Madison St. Suite 3300 Address: City, State, Zip Chicago, IL 60602
OCT 1 8 2002
| Contact Person: | Name: | Richard O. Wood |
|-----------------|------------|----------------------------------------|
| | Phone/Fax: | (312) 807-4364<br>(312) 827-8189 (Fax) |
| | Email: | rowood@bellboyd.com |
| Date Prepared: | Date: | September 5, 2002 |
### 9.2 Name of Device and Name/Address of Applicant
Aquilla Model Wheelchair
Haywood Vocational Opportunities, Inc. 56 Scates St., Waynesville, N.C. 28786,
### 9.3 Name and Address of Manufacturer
Remploy Mobility Jubilee Industrial Estate, Ashington, Northumberland, United Kingdom NE63 8UE 01670 813718 01670 851990 (Fax)
### 9.4 Common or Usual Name
Mechanical wheelchair
### 9.5 Classification Name
Wheelchair, mechanical
{1}------------------------------------------------
09/04/02
---
KOD 300
2002
### 9.6 Predicate Device
The Aquilla wheelchair is substantially equivalent to the Breezy® 510 model wheelchairs manufactured by Sunrise Medical (K974820, 1/27/1998).
### 9.7 Intended Use
The Aquilla Modular Wheelchair is intended to provide mobility for occupants who are unable to walk or have difficulty in walking without assistance.
### 9.8 Technological Characteristics and Substantial Equivalence
### 9.8.1 Device Description
The Aquilla Modular Wheelchair is manually operated, and can be configured for propulsion by an attendant or an occupant. The range of sizes and build configurations are suitable for male or female sizes from junior to adult.
The Aquilla Modular Wheelchair consists of typical components found on most manual wheelchairs. The chairs feature a backrest, folding seat frame, footrest, rear wheels and front castors. Accessories include occupant-positioning belts, and optional features which allow a chair to be changed simply to meet the changing environmental and health requirements of the occupant.
Aquilla is suitable for use both indoors and outdoors on surfaces that are intended typically for public access. This type of wheelchair is not suitable for soft and undulating terrain or for climbing obstacles. Aquilla can be easily folded for compact storage, and armrests and footrests can be removed to reduce the weight for lifting.
Aquilla is labeled to indicate important aspects of use, including warnings and cautions.
### 9.8.2 Substantial Equivalence
The Aquilla Modular Wheelchair is substantially equivalent to the Breezy® 510 wheelchair manufactured by Sunrise Medical (K974820, 1/27/98). They are both lightweight wheelchairs with the intended use of providing mobility to occupants unable to walk or have difficulty in walking without assistance.
### 9.9 Performance Data
The Aquilla wheelchair has been tested to and met the following ISO requirements: ISO 7176-1, -3, -5, -7, -8, -15, -16, -19.
{2}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized graphic of an eagle or bird-like figure, composed of three curved lines that suggest wings and a head.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
OCT 1 8 2002
Haywood Vocational Opportunities Bell, Boyd & Lloyd, LCD c/o Richard O. Wood 70 W. Madison Street, Suite 3300 Chicago, Illinois 60670
### Re: K023005
Trade/Device Name: Aquilla Modular Wheelchair Regulation Number: 890.3850 Regulation Name: Wheelchair, mechanical Regulatory Class: Class I Product Code: IOR Dated: September 4, 2002 Received: September 9, 2002
Dear Mr. Wood:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
Page 2 - Mr. Richard O. Wood ·
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely vours.
Sincerely yours,
O Mark N Millenn
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
510(k) Number (if known):
Device Name: Aquilla Modular Wheelchair
# 1. INDICATIONS FOR USE:
### Aquilla Modular Wheelchair:
The Aquilla Modular Wheelchair is intended to provide mobility for occupants who are unable to walk or have difficulty in walking without assistance.
## (PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Mark n Milkerso
(Division Sign-Off) Di ision of General : storative and Neurological Deloces 510(k) Number _
Prescription Use
OR
Over-The-Counter Use X
(Optional Format 1-2-96)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.