LUMENIS VERSAPULSE POWERSUITE HOLMIUM (HO:YAG) AND DUAL WAVELENGTH (HO:YAG/ND:YAG) SURGICAL LASERS AND DELIVERY DEVICES
K011703 · Lumenis · GEX · Aug 29, 2001 · General, Plastic Surgery
Device Facts
Record ID
K011703
Device Name
LUMENIS VERSAPULSE POWERSUITE HOLMIUM (HO:YAG) AND DUAL WAVELENGTH (HO:YAG/ND:YAG) SURGICAL LASERS AND DELIVERY DEVICES
Applicant
Lumenis
Product Code
GEX · General, Plastic Surgery
Decision Date
Aug 29, 2001
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4810
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The modified and the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories are intended for use in surgical procedures involving open, laparoscopic and endoscopic ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: urology; urinary lithotripsy; arthroscopy; discectomy; E.N.T. surgery; gynecological surgery; pulmonary surgery; gastroenterology surgery; dermatology and plastic surgery and general surgery. The modified and the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with accessories are indicated for use in the performance of specific surgical applications in urology, urinary lithotripsy, arthroscopy/orthopaedics, discectomy, E.N.T. surgery, gynecological surgery/gynecology, general surgery, gastroenterology, thoracic and pulmonary surgery, dermatology and plastic surgery, podiatry, and limited indications in neurosurgery, ophthalmology, and lumbar discectomy.
Device Story
The VersaPulse PowerSuite is a surgical laser system comprising a console, microprocessor control, display panel, footswitch/handswitch, and fiber optic delivery devices. It delivers Ho:YAG (Holmium) or dual-wavelength (Ho:YAG/Nd:YAG) laser energy to target tissues. Operated by physicians in OR, clinic, or endoscopic settings, the device enables precise ablation, vaporization, incision, excision, and coagulation. The surgeon controls energy delivery via handpieces or probes; output is visualized directly or endoscopically. The system facilitates minimally invasive procedures, potentially reducing patient trauma and recovery time compared to traditional open surgery.
Clinical Evidence
Bench testing only. No clinical data provided. Substantial equivalence is based on design, functional features, and indications for use identical to previously cleared predicate devices.
Technological Characteristics
Laser console with microprocessor control, fiber optic delivery system, and footswitch/handswitch. Emits Ho:YAG and/or Nd:YAG laser energy. Components include laser connector, handpiece, probe tube, and fiber optic cable. System is a powered surgical instrument (Product Code GEX, Regulation 878.4810).
Indications for Use
Indicated for surgical ablation, vaporization, excision, incision, and coagulation of soft tissue across multiple specialties including urology (BPH, lithotripsy, tumors), orthopedics/arthroscopy, discectomy (L4-S1), general surgery, ENT, gynecology, gastroenterology, pulmonary, dermatology, plastic surgery, podiatry, neurosurgery (hemostasis), and ophthalmology (post-vitrectomy). Patient population includes adults requiring soft tissue surgery or specific indicated procedures like lumbar discectomy for patients with unilateral leg pain, positive straight leg raise, and MRI-confirmed subligamentous herniation.
Regulatory Classification
Identification
(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
{0}------------------------------------------------
# AUG 2 9 2001
Attachment 11
K 011703
510(k) Summary Statement for the Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
#### I. General Information
| Submitter: | Lumenis<br>2400 Condensa Street<br>Santa Clara, California, U. S. A.<br>95051-0901 |
|---------------------------|------------------------------------------------------------------------------------|
| Contact Person: | Lisa G. McGrath |
| Summary Preparation Date: | May 30, 2001 |
- II. Names
PowerSuite VersaPulse Device Names: Modified Lumenis Dual Wavelength (Ho:YAG) and Holmium (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories Surgical Instrument (and Powered Primary Classification Name: Laser Accessories)
## III. Predicate Devices
- and VersaPulse PowerSuite Holmium (Ho:YAG) Dual Wavelength . (Ho:YAG/Nd:YAG) Surgical Lasers (K990947);
- Trimedyne Holmium Laser Systems (model 1210, model 1010-VHP, and model . 1500-A) (K002308)
- Dornier Medilas H/2 Laser System (K984591) .
- Convergent Odyssey 30 Laser System (K951910). .
## IV. Product Description
The Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers that are the subject of this Premarket Notification 510(k) submission are comprised of the following functional components:
- a laser console;
- control and display panel;
{1}------------------------------------------------
- a fiber port for delivery systems; .
- system microprocessor control electronics; •
- a covered footswitch or handswitch; .
- . operating software;
- an optional remote control unit; .
- a variety of fiber optic delivery devices with accessories. .
The Lumenis delivery devices that are the subject of this Premarket Notification 510(k) submission are comprised of all or some (depending on the product configuration) of the following functional components:
- laser connector;
- handpiece;
- probe tube;
- probe tip;
- fiber optic cable.
#### V. Indications for Use
The modified and the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers are intended for use in surgical procedures involving open, laparoscopic and endoscopic ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including:
- urology; urinary lithotripsy; arthroscopy; discectomy; Ho:YAG o E.N.T. surgery; gynecological surgery; ppulmonary surgery : gastroenterology surgery; dermatology and plastic surgery and general surgery.
- urology; general surgery; gastroenterology; thoracic & Nd:YAG o pulmonary surgery; E.N.T. surgery; podiatry; orthopaedics; dermatology and plastic surgery and with limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy.
The modified and the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers are indicated for use in the performance of specific surgical applications in urology, urinary lithotripsy, arthroscopy/orthopaedics, discectomy, E.N.T. surgery, gynecological surgery/gynecology, general surgery, gastroenterology, thoracic and pulmonary surgery, dermatology and plastic surgery, podiatry, and limited indications in neurosurgery, ophthalmology, and lumbar discectomy as follows:
{2}------------------------------------------------
#### Page 3
# Ho:YAG - Urology
- endoscopic transurethral incision of the prostate (TUIP), bladder neck ● incision of the prostate (BNI), holmium laser ablation of the prostate (HoLAP), holmium laser enucleation of the prostate (HoLEP),holmium laser resection of the prostate (HoLRP), hemostasis, vaporization and excision for treatment of benign prostatic hypertrophy (BPH);
- open and endoscopic urological surgery (ablation, vaporization, incision, . excision and coagulation of soft tissue) including treatment of:
- bladder; O
- superficial and invasive bladder, urethral and ureteral tumors; O
- condylomas; O
- lesions of external genitalia; o
- ureteral and penile hemangioma; O
- 0 ureteral strictures;
- bladder neck obstructions. o
- Urinary Lithotripsy including: .
- endoscopic fragmentation of urinary (urethral, ureteral, bladder and o renal) calculi, including cystine, calcium oxalate, monohydrate and calcium oxalate dihydrate stones;
- treatment of distal impacted fragments of steinstrasse when guide wires o cannot be passed.
## Nd:YAG - Urology
- Urological surgery (ablation, vaporization, incision, excision and coagulation ● of soft tissue) including:
- removal of superficial bladder tumors; O
- removal of invasive bladder carcinoma; 0
- removal of benign or malignant lesions of the external genitalia, including 0 condylomas;
- treatment of urethral strictures; O
- treatment of vascularities of the bladder wall; O
- prostatectomy. 0
### Ho:YAG - Arthroscopy
- Arthroscopy/orthopaedic surgery (ablation, excision and coagulation of soft ● and cartilaginous tissue) in various small and large joints of the body, excluding the spine, including:
- meniscectomy; o
- o plica removal;
{3}------------------------------------------------
- ligament and tendon release; 0
- contouring and sculpting of articular surfaces; 0
- debridement of inflamed synovial tissue (synovectomy); o
- loose body debridement; O
- chondromalacia and tears; O
- lateral retinecular release; O
- capsulectomy in the knee 0
- chondroplasty in the knee; O
- chondromalacia ablation. O
- . Discectomy including:
- percutaneous vaporization of the L4-5 and L5-S1 lumbar discs of the o vertebral spine; open and arthroscopic spine procedures; foraminotomy.
### Nd:YAG - Orthopaedic Surgery
- Arthroscopy (ablation, vaporization, incision, excision, and coagulation of . soft tissue) including:
Knee
- capsulectomy in the knee; O
- chondroplasty in the knee; O
- plica removal in the knee; 0
- lateral ligament release in the knee; 0
- meniscectomy in the knee; ಂ
- synovectomy in the knee; O
- osteoarthritic lesion removal in the knee; 0
#### Shoulder
- coracoacromial release in the shoulder; 0
- debridement of scar tissue in the shoulder; 0
- adhesive capsule release in the shoulder; 0
- labral tear repair in the shoulder; 0
- synovectomy in the shoulder. O
- . Discectomy:
limited to open, percutaneous and arthroscopic vaporization of the L4-5 and L5-S1 lumbar discs of the vertebral spine in patients with:
- unilateral leg pain greater than back pain; O
- paresthetic discomfort in a specific dermatomal distribution; O
- O positive straight leg raising test and/or positive bowstring sign;
- possible neurologic finding including wasting, weakness, sensory 0 alteration and reflex alteration;
- no improvement after at least 6 weeks of conservative therapy; O
{4}------------------------------------------------
## Page 5
- positive CT or MRI showing a subligamentous herniation at the location O consistent with clinical findings.
# Ho:YAG - General Surgery
- Open, laparoscopic, and endoscopic general surgery (vaporization, ablation, . incision, and coagulation of soft tissue) including:
- cholecystectomy; ಂ
- lysis of adhesions; O
- appendectomy; o
- appendectorny, and removal of polyps of the sigmoid colon; o
- skin incision; 0
- tissue dissection; o
- excision of external tumors and lesions; 0
- complete or partial resection of internal organs, tumors and lesions; 0
- mastectomy; 0
- hepatectomy; 0
- pancreatectomy; 0
- splenectomy; o
- thyroidectomy; 0
- parathyroidectomy; o
- herniorrhaphy; O
- tonsillectomy; O
- lymphadenectomy; 0
- partial nephrectomy; 0
- pilonidal cystectomy; O
- resection of lipoma; 0
- debridement of decubitus ulcer; O
- hemorrhoids; O
- debridement of statis ulcer; 0
- biopsy. O
## Nd:YAG - General Surgery
- Open, laparoscopic, and endoscopic general surgery (ablation, vaporization, . incision, excision, and coagulation of soft tissue) including:
- cholecystectomy; o
- mastectomy; 0
- hepatectomy; O
- pancreatectomy; ಂ
- o splenectomy;
- hemorrhoidectomy; o
{5}------------------------------------------------
- thyroidectomy; ಂ
- parathyroidectomy; ಂ
- herniorrhaphy; ಂ
- tonsillectomy; O
- appendectomy; 0
- lymphadenectomy; O
- partial nephrectomy; 0
- pilonidal cystectomy; O
- resection of lipoma; 0
- O pelvic adhesiolysis;
- removal of lesions; O
- removal of polyps; O
- removal of tumors; 0
- tumor biopsy; O
- debridement of decubitus ulcers. O
# Ho:YAG - E.N.T. Surgery
- . Endoscopic endonasal/sinus surgery (ablation, vaporization, incision, and coagulation of soft tissue and cartilage) including:
- partial turbinectomy; 0
- ethmoidectomy; 0
- polypectomy; o
- maxillary antrostomy; 0
- frontal sinusotomy; o
- sphenoidotomy; o
- dacryocystorhinostomy (DCR); O
- O functional endoscopic sinus surgery (FESS).
### Nd:YAG-E.N.T. Surgery
- Endonasal surgery (ablation, vaporization, incision, excision, and coagulation . of soft tissue) including:
- o lesions or tumors of the oral, nasal, glossal, pharyngeal and laryngeal tissues;
- tonsillectomy; O
- adenoidectomy. O
#### Ho:YAG - Gynecological Surgery
- Open and laparoscopic gynecological surgery (ablation, vaporization, . incision, excision, and coagulation of soft tissue).
#### Nd:YAG - Gynecological Surgery
- . Gynecological surgery limited to:
{6}------------------------------------------------
Page 7
- treatment of menorrhagia by the photocoagulation, vaporization, or o the endometrial lining of the uterus under direct ablation, of hysteroscopic visualization;
- intra-uterine treatment of submucous fibroids, benign endometrial o polyps, and uterine septum by incision, excision, ablation, and/or vessel coagulation;
- intra-abdominal treatment of endometriosis and/or peritoneal adhesions O with laser contact tips;
- soft tissue excisional procedures such as excisional conization of the O cervix.
# Ho:YAG - Gasteroenterology Surgery
- Open and endoscopic gasteroenterology surgery (ablation, vaporization, . incision, excision, resection, coagulation and hemostasis, including:
- O gall bladder calculi;
- biliary/bile duct calculi; O
- benign and malignant neoplasm; 0
- polyps; 0
- colitis; O
- 0 ulcers;
- angiodysplasia; 0
- hemorrhoids; 0
- varices; 0
- esophagitis; 0
- esophageal ulcer; O
- Mallory-Weiss tear; O
- gastric ulcer; 0
- O duodenal ulcer;
- non-bleeding ulcer; O
- gastric erosions; ಂ
- colorectal cancer; o
- gastritis; O
- bleeding tumors; o
- pancreatitis; ಂ
- O vascular malformations;
- telangiectasias; 0
- telangiectasias of the Osler-Weber-Renu disease. 0
## Nd:YAG - Gastroenterology Surgery
- . Gastroenterology surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- partial removal of neoplastic tissue in the management of esophageal O obstruction for symptomatic relief of dysphagia;
{7}------------------------------------------------
Page 8
- gastrointestinal hemostasis including, varicies, esophagitis, esophageal O ulcer, Mallory-Wiess tear, gastric ulcer, angiodysplasia, stomal ulcers, non-bleeding ulcers, and gastric erosions;
- gastrointestinal tissue ablation of benign and malignant neoplasm, 0 hemorrhoids and polyps.
# Ho:YAG - Pulmonary Surgery
- Open and endoscopic pulmonary surgery (cutting, ablation, vaporization, . incision, excision and coagulation of soft tissue).
# Nd:YAG - Thoracic and Pulmonary Surgery
- Thoracic and pulmonary surgery (ablation, vaporization, incision, excision, . and coagulation of soft tissue) including treatment of:
- laryngeal lesions; ಂ
- airway obstructions including carcinoma; 0
- polyps and granulomas; O
- palliation of obstructing carcinomas of the tracheobronchial tree. 0
# Ho:YAG - Dermatology and Plastic Surgery
- excision, resection, ablation, coagualation, hemostasis and . Incision, vaporization of soft, mucosal, fatty and cartilaginous tissues, in therapeutic plastic, dermatologic and aesthetic surgical procedures, including:
- scars; o
- tattoo removal; O
- vascular lesions; o
- port wine stains; o
- ಂ hemangioma;
- telangiectasia of the face and leg; 0
- O rosacea;
- corns; 0
- papillomas; O
- basal cell carcinomas; O
- lesions of skin and subcutaneous tissue; 0
- plantar warts; o
- periungual and subungual warts; o
- debridement of decubitus ulcer; O
- skin tag vaporization. O
# Nd:YAG - Dermatology and Plastic Surgery
- Dermatology and plastic surgery (ablation, vaporization, incision, excision, . and coagulation of soft tissue) including:
- lesions of skin and subcutaneous tissue; O
- telangiectasia; o
- port wine lesions; O
{8}------------------------------------------------
- spider veins; O
- hemangiomas; 0
- 0 plantar warts;
- periungual and subungual warts; O
- removal of tattoos; O
- debridement of decubitus ulcer; 0
- treatment of keloids. O
#### Nd:YAG - Podiatry
- . Podiatry (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- matrixectomy; o
- plantar warts; 0
- neuromas; ರ
- periungual and subungual warts; O
- radical nail excision. O
## Nd:YAG - Neurosurgery
- Neurosurgery limited to: .
- hemostasis in neurosurgery procedures such as excision of brain lesions, o spinal cord lesions, cranial nerves, peripheral nerves, and pituitary glands.
Nd:YAG - Ophthalmology
- Ophthalmology limited to: ●
- o post-vitrectomy photocoagulation.
#### V. Rationale for Substantial Equivalence
The Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories share the same intended use, indications for use, similar design features, functional features, and therefore are substantially equivalent to the PowerSuite Holmium (Ho:YAG) and Dual Wavelength VersaPulse (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories.
In addition, the Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers are substantially equivalent in terms of indications for use to the Trimedyne Holmium Laser Systems (model 1210, model 1010-VHP, and model 1500-A) (K002308), the Dornier Medilas H/2 Laser System (K984591) and the Convergent Odyssey 30 Laser System (K951910).
{9}------------------------------------------------
> The Lumenis delivery devices are substantially equivalent to the previously cleared delivery devices in K990947.
#### VII. Safety and Effectiveness Information
Safety and effectiveness information was provided to demonstrate that the Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories are safe and effective, when indicated for use for general and specific applications in the medical specialties of urology; urinary lithotripsy; arthroscopy; discectomy; E.N.T. surgery; gynecological surgery; pulmonary surgery, gastroenterology surgery, dermatology and plastic surgery and general surgery; for Ho:YAG and urology; general surgery; gastroenterology; thoracic and pulmonary surgery; E.N.T. surgery; podiatry; orthopaedics; and with limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy for Nd:YAG.
#### Conclusion VIII.
The Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories were found to be substantially equivalent to similar currently marketed and predicate surgical lasers, delivery devices and accessories.
The Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories share the same intended use, indications for use, similar design features, and similar functional features as the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories. The Modified Lumenis PowerSuite Holmium (Ho:YAG) and Dual Wavelength VersaPulse (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories is also substantially equivalent in terms of indications for use to the Trimedyne Holmium Laser Systems (model 1210, model 1010-VHP, and model 1500-A) (K002308), the Dornier Medilas H/2 Laser System (K984591) and the Convergent Odyssey 30 Laser System (K951910).
{10}------------------------------------------------
Image /page/10/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle or bird-like figure with three stylized wing segments.
AUG 2 9 2001
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Ms. Lisa G. McGrath Senior Regulatory Affairs Associate Lumenis 2400 Condensa Street Santa Clara, California 95051
Re: K011703
Trade/Device Name: Modified Lumenis VersaPulse® PowerSuite®™ Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers & Delivery Devices with Accessories
Devices with Accessories
. 878 4810
Regulation Number: 878.4810 Regulatory Class: II Product Code: GEX Dated: May 30, 2001 Received: June 1, 2001
Dear Ms. McGrath:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{11}------------------------------------------------
Page 2 - Ms. Lisa G. McGrath
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed notification. The I Driving of succion for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and II you desire specific advices), your actices), please contact the Office of Compliance at additionally 807.10 for mirrito than its promotion and advertising of your device, (301) 594-4639. Traditionally, appliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Information on your responsibilities and er Assistance at its toll-free number (800) 638-2041 or Manufacturers Internet and Colless "http://www.fda.gov/cdrh/dspa/dsmamain.html".
Sincerely yours,
l Mark n Millkenso
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative
and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{12}------------------------------------------------
# Attachment 3 Indications For Use Statement
| 510(k) Number (if Known): | KD111703 |
|---------------------------|----------|
|---------------------------|----------|
# Device Name: Modified Lumenis VersaPulse® PowerSuite™ Holmium (Ho:YAG) and Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers & Delivery Dual Devices with Accessories
#### Indications For Use:
The modified and the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) The Inounced and the colors (Ho:YAG) Surgical Lasers and Delivery Devices with and Duar Warelengan (sfor use in surgical procedures involving open, laparoscopic and accessories are antention, excision, excision, incision, and coagulation of soft tissue in medical specialties including:
- urology; urinary lithotripsy; arthroscopy; discectomy; E.N.T. . Ho:YAG surgery; gynecological surgery; pulmonary surgery; gastroenterology surgery; dermatology and plastic surgery and general surgery.
- urology; general surgery; gastroenterology; thoracic & pulmonary Nd:YAG -. I N.T.T. surgery; podiatry; orthopaedics; dermatology and plastic surgery; surgery El With limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy.
The modified and the currently marketed VersaPulse PowerSuite Holmium (Ho:YAG) The Inounced and the PHG/Nd:YAG) Surgical Lasers and Delivery Devices with accessories are indicated for use in the performance of specific surgical applications in uccebooks urinary lithotripsy, arthroscopy/orthopaedics, discectomy, E.N.T. surgery, gynecological surgery/gynecology, general surgery, gastroenterology, thoracic and 57.00000gear enatology and plastic surgery, podiatry, and limited indications in neurosurgery and ophthalmology as follows:
# *** Indications For Use Continued on Next Page (9 pages total) ***
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Mark of CDRH, Office of Device Evaluation (ODE)
Division Sign-Off) Division of General, Restorative and Neurological Devices
510(k) Number
Prescription Use
(Per 21 CFR 801.109)
K
Or
Over-The-Counter Use (Optional Format 1-2-96)
{13}------------------------------------------------
Attachment 3 -- Continued (page 2 of 9) Indications For Use Statement
510(k) Number (if Known):_
# Device Name: Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Modified Lumicino Ho:YAGNd:YAG) Surgical Lasers and Delivery Devices with Accessories
# Indications For Use:
#### Ho:YAG - Urology
- Endoscopic transurethral incision of the prostate (TUIP), bladder neck incision of . Endoscopic trailSureunan incision of the prostate (HoLAP), holmium in the prostate (UNI), nominatif itser as the Resertion of the prostate laser enucleation of the prosule (110222)// hours for treatment of benign prostatic hypertrophy (BPH);
- hypertropliy (DFTI),
Open and endoscopic urological surgery (ablation, vaporization, incision, Open "and coagulation of soft tissue) including treatment of:
- bladder; O
- Diadder,
superficial and invasive bladder, urethral and ureteral tumors; o
- condylomas; 0
- lesions of external genitalia; o
- ureteral and penile hemangioma; O
- ureteral strictures; O
- bladder neck obstructions. o
- Urinary Lithotripsy including:
- y Elthouripsy therating.
endoscopic fragmentation of urinary (urethral, ureteral, bladder and O encobcopic ii againding cystine, calcium oxalate, monohydrate and calcium oxalate dihydrate stones;
- calcrail oxalate anympacted fragments of steinstrasse when guide wires 0 cannot be passed.
### Nd:YAG - Urology
- Urological surgery (ablation, vaporization, incision, excision and coagulation of . soft tissue) including:
- removal of superficial bladder tumors; o
- removal of invasive bladder carcinoma; 0
- removal of invasive malignant lesions of the external genitalia, including O condylomas;
- treatment of urethral strictures; O
- treatment of vascularities of the bladder wall;
- prostatectomy.
Mark n millers
Division Sign-Off
Division of General, Restorative
510(k) Number K
{14}------------------------------------------------
Attachment 3- Continued (page 3 of 9) Indications For Use Statement
510(k) Number (if Known):_
Device Name: Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
# Indications for Use:
## Ho:YAG - Arthroscopy
- G = Artifioscopy (ablation, excision and coagulation of soft and cartilaginous tissue) � Arthroscopy (ablandit) excluding and coup.
in various small and large joints of the body, excluding the spine, including:
- meniscectomy; o
- plica removal; 0
- ligament and tendon release; 0
- contouring and sculpting of articular surfaces; 0
- contidement of inflamed synovial tissue (synovectomy); 0
- loose body debridement; 0
- chondromalacia and tears; 0
- lateral retinecular release; 0
- capsulectomy in the knee 0
- chondroplasty in the knee; o
- chondromalacia ablation. O
- Discectomy including: .
- tomy including.
percutaneous vaporization of the L4-5 and L5-S1 lumbar discs of the o perculaneous vaporization throscopic spine procedures; foraminotomy.
# Nd:YAG - Orthopaedic Surgery
- Arthroscopy (ablation, vaporization, incision, excision, and coagulation of soft ● tissue) including:
Knee
- capsulectomy in the knee; O
- chondroplasty in the knee; O
- plica removal in the knee; O
- lateral ligament release in the knee; o
- meniscectomy in the knee; O
- synovectomy in the knee; 0
- osteoarthritic lesion removal in the knee; o
#### Shoulder
- coracoacromial release in the shoulder; O
- debridement of scar tissue in the shoulder;
Mark N. Milbauer
on of General. Restorative
510(k) Number K
{15}------------------------------------------------
# Attachment 3 - Continued (page 4 of 9) Indications For Use Statement
510(k) Number (if Known):_
# Device Name: Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
## Indications For Use:
Nd:YAG - Orthopaedic Surgery - Continued
- adhesive capsule release in the shoulder; o
- labral tear repair in the shoulder; o
- synovectomy in the shoulder. o
#### Discectomy: .
Discectority.
Imited to open, percutaneous and arthroscopic vaporization of the L4-5 and L5-S1 lumbar discs of the vertebral spine in patients with:
- unilateral leg pain greater than back pain; O
- annateral leg paint ---------------------------------------------------------------------------------------------------------------------------------------------------------o
- positive straight leg raising test and/or positive bowstring sign; O
- possible neurologic finding including wasting, weakness, sensory 0 alteration and reflex alteration;
- no improvement after at least 6 weeks of conservative therapy; O
- positive CT or MRI showing a subligamentous herniation at the O location consistent with clinical findings.
### Ho:YAG - General Surgery
.
- Open, laparoscopic, and endoscopic general surgery (vaporization, ablation, incision, and coagulation of soft tissue) including:
- cholecystectomy; 0
- lysis of adhesions; O
- appendectomy; 0
- appendectorry/
biopsy, pylorostenotomy, and removal of polyps of the sigmoid colon; ಂ
- skin incision; 0
- tissue dissection; ೦
- excision of external tumors and lesions; 0
- complete or partial resection of internal organs, turnors and lesions; O
- mastectomy; ಂ
- hepatectomy; O
- pancreatectomy; O
- splenectomy; ಂ
- thyroidectomy; 0
- parathyroidectomy; 0
Mark N Milken
(Division Sign-Off) (Division of General, Restorative and Neurological Devices
510(k) Number
{16}------------------------------------------------
# Attachment 3 - Continued (page 5 of 9) Indications For Use Statement
510(k) Number (if Known):_
# Device Name: Modified Lumenis VersaPulse PowerSuite Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
## Indications For Use:
Ho:YAG - General Surgery - Continued
o herniorrhaphy;
o tonsillectomy;
o lymphadenectomy;
o partial nephrectomy;
o pilonidal cystectomy;
o resection of lipoma;
o debridement of decubitus ulcer;
o hemorrhoids;
o debridement of statis ulcer;
o biopsy.
#### Nd:YAG - General Surgery
- Open, laparoscopic, and endoscopic general surgery (ablation, vaporization, . incision, excision, and coagulation of soft tissue) including:
- cholecystectomy; o
- mastectomy; o
- hepatectomy; 0
- pancreatectomy; 0
- splenectomy; O
- hemorrhoidectomy; 0
- thyroidectomy; O
parathyroidectomy; O
- herniorrhaphy; 0
tonsillectomy; 0
- appendectomy; 0
- lymphadenectomy; 0
partial nephrectomy; O
- pilonidal cystectomy; O
resection of lipoma; 0
- pelvic adhesiolysis; O
- removal of lesions; O
- removal of polyps; O
- removal of tumors; o
tumor biopsy; O
debridement of decubitus ulcers. O
to Mark N Mulbernan
011703
(Division Sign-Off) Division of General, Restorative and Neurological Devices
510(k) Number
Attachment 3, Page 5
{17}------------------------------------------------
Attachment 3 - Continued (page 6 of 9) Indications For Use Statement
510(k) Number (if Known):
# Device Name: Modified Lumenis VersaPulse Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
### Indications For Use:
#### Ho: YAG - E.N.T. Surgery
- Endoscopic endonasal/sinus surgery (ablation, vaporization, incision, and . coagulation of soft tissue and cartilage) including:
- partial turbinectomy; o
- ethmoidectomy; O
- polypectomy; O
- maxillary antrostomy; 0
- frontal sinusotomy; ಂ
- sphenoidotomy; O
- dacryocystorhinostomy (DCR); o
eral, Restorative and Neurological Devices
- dacryocystoriumostomy (DCx), "FESS)10(k) Number -O
## Nd:YAG-E.N.T. Surgery
- Endonasal surgery (ablation, vaporization, incision, excision, and coagulation of . soft tissue) including:
- lesions or tumors of the oral, nasal, glossal, pharyngeal and laryngeal o tissues:
- tonsillectomy; O
- adenoidectomy. o
#### Ho:YAG - Gynecological Surgery
.
- Open and laparoscopic gynecological surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue).
#### Nd:YAG - Gynecological Surgery
- Gynecological surgery limited to: .
- treatment of menorrhagia by the photocoagulation, vaporization, or o ablation, of the endometrial lining of the uterus under direct hysteroscopic visualization;
- intra-uterine treatment of submucous fibroids, benign endometrial O polyps, and uterine septum by incision, excision, ablation, and/or vessel coagulation;
- intra-abdominal treatment of endometriosis and/or peritoneal adhesions O with laser contact tips;
- soft tissue excisional procedures such as excisional conization of the O cervix.
{18}------------------------------------------------
# Attachment 3 - Continued (page 7 of 9) Indications For Use Statement
510(k) Number (if Known):_
# Device Name: Modified Lumenis VersaPulse Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
# Indications For Use:
Ho:YAG - Gasteroenterology Surgery
- Open and endoscopic gasteroenterology surgery (ablation, vaporization, . incision, excision, resection, coagulation and hemostasis, including:
- gall bladder calculi; o
- biliary / bile duct calculi; ಂ
- o benign and malignant neoplasm;
- polyps; ಂ
- colitis; o
- ulcers; 0
- angiodysplasia; 0
- hemorrhoids; o
- varices; O
- esophagitis; 0
- esophageal ulcer; 0
- Mallory-Weiss tear; 0
- gastric ulcer; O
- duodenal ulcer; O
- non-bleeding ulcer; O
- gastric erosions; 0
- colorectal cancer; 0
- gastritis; O
- bleeding tumors; O
- pancreatitis; O
- vascular malformations; O
- telangiectasias; 0
- telangiectasias of the Osler-Weber-Renu disease. 0
# Nd:YAG - Gastroenterology Surgery
- Gastroenterology surgery (ablation, vaporization, incision, excision, and � coagulation of soft tissue) including:
- partial removal of neoplastic tissue in the management of esophageal O obstruction for symptomatic relief of dysphagia;
- gastrointestinal hemostasis including, varicies, esophagitis, esophageal O ulcer, Mallory-Wiess tear, gastric ulcer, angiodysplasia, stomal ulcers, non-bleeding ulcers, and gastric erosions;
- gastrointestinal tissue ablation of benign and malignant neoplasm, 0 hemorrhoids and polyps.
Mark N Milburn
Division Sign-Off Division of General, Restorative and Neurological Devices KO11903
510(k) Number -
{19}------------------------------------------------
# Attachment 3 - Continued (page 8 of 9) Indications For Use Statement
510(k) Number (if Known):
# Device Name: Modified Lumenis VersaPulse Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
Indications For Use:
### Ho:YAG - Pulmonary Surgery
- . Open and endoscopic pulmonary surgery (cutting, ablation, vaporization, incision, excision and coagulation of soft tissue).
## Nd:YAG - Thoracic and Pulmonary Surgery
- Thoracic and pulmonary surgery (ablation, vaporization, incision, excision, and . coagulation of soft tissue) including treatment of:
- laryngeal lesions; o
- airway obstructions including carcinoma; 0
- polyps and granulomas; 0
- palliation of obstructing carcinomas of the tracheobronchial tree. 0
#### Ho:YAG - Dermatology and Plastic Surgery
- Incision, excision, resection, ablation, coagualation, hemostasis and vaporization . of soft, mucosal, fatty and cartilaginous tissues, in therapeutic plastic, dermatologic and aesthetic surgical procedures, including:
- scars; O
- tattoo removal; O
- vascular lesions; 0
- O port wine stains;
- hemangioma; 0
- telangiectasia of the face and leg; O
- rosacea; 0
- corns; 0
- papillomas; O
- basal cell carcinomas; 0
- lesions of skin and subcutaneous tissue; 0
- plantar warts; ಂ
- periungual and subungual warts; O
- debridement of decubitus ulcer; O
- skin tag vaporization. O
for Mark n Mulkers
Division Sign-Off) Division of General, Restorative and Neurological Devices
510(k) Number_
Attachment 3, Page 8
{20}------------------------------------------------
# Attachment 3 - Continued (page 9 of 9) Indications For Use Statement
510(k) Number (if Known):_
Device Name: Modified Lumenis VersaPulse Holmium (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
#### Indications For Use:
Nd:YAG - Dermatology and Plastic Surgery
- Dermatology and plastic surgery (ablation, vaporization, incision, excision, and . coagulation of soft tissue) including;
- lesions of skin and subcutaneous tissue; o
- telangiectasia; o
- port wine lesions; 0
- spider veins; O
- hemangiomas; 0
- plantar warts; 0
- periungual and subungual warts; 0
- removal of tattoos; O
- debridement of decubitus ulcer; 0
- treatment of keloids. O
Nd:YAG - Podiatry
- Podiatry (ablation, vaporization, incision, excision, and coagulation of soft tissue) . including:
- matrixectomy; o
- plantar warts; 0
- neuromas; 0
- periungual and subungual warts; 0
- radical nail excision. ರ
#### Nd:YAG - Neurosurgery
.
- Neurosurgery limited to:
- hemostasis in neurosurgery procedures such as excision of brain lesions, o cranial nerves, peripheral nerves, and pituitary spinal cord lesions, glands.
Nd:YAG - Ophthalmology
- Ophthalmology limited to: ●
- post-vitrectomy photocoagulation. ಂ
***(page 9 of 9) ***
Attachment 3, Page 9
Mark n Mullerson
Division Sign-Off
510(k) Number
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.