MODIFIED VERSAPULSE SELECT SINGLE WAVELENGTH, HO: YAG AND DUAL WAVELENGTH, HO: YAG/ND: YAG SURGICAL LASERS AND DELIVERY
K990947 · Lumenis, Inc. · GEX · Apr 27, 1999 · General, Plastic Surgery
Device Facts
Record ID
K990947
Device Name
MODIFIED VERSAPULSE SELECT SINGLE WAVELENGTH, HO: YAG AND DUAL WAVELENGTH, HO: YAG/ND: YAG SURGICAL LASERS AND DELIVERY
Applicant
Lumenis, Inc.
Product Code
GEX · General, Plastic Surgery
Decision Date
Apr 27, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4810
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The modified and currently marketed Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers are intended for use in surgical procedures involving open, laparoscopic and endoscopic ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including: Ho:YAG - urology; urinary lithotripsy; arthroscopy; discectomy; endonasal surgery; gynecological surgery; and general surgery; and Nd:YAG - urology; general surgery; gastroenterology; thoracic and pulmonary surgery; ENT surgery; podiatry; orthopaedics; and with limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy.
Device Story
Modified Coherent VersaPulse Select surgical laser system delivers Ho:YAG and/or Nd:YAG laser energy to soft tissue. System comprises laser console, microprocessor control, display panel, footswitch/handswitch, and fiber optic delivery devices (handpieces, probes). Used by physicians in OR, clinic, or endoscopic settings for ablation, vaporization, excision, incision, and coagulation. Laser energy is transmitted via fiber optic cable to target tissue; clinical effect achieved through thermal interaction. Output allows precise tissue management, reducing need for traditional scalpel surgery. System includes sterilization trays for accessories. Healthcare providers use visual feedback (endoscopic/direct) to guide laser application, directly impacting surgical precision and patient recovery.
Clinical Evidence
No clinical data provided; substantial equivalence is based on design, functional, and intended use similarities to previously cleared predicate devices.
Technological Characteristics
Laser system utilizing Ho:YAG and Nd:YAG wavelengths. Components include laser console, microprocessor control, fiber optic delivery systems, and sterilization trays. Connectivity includes remote control unit. Software-controlled operation. Sterilization trays provided for accessories.
Indications for Use
Indicated for soft tissue ablation, vaporization, excision, incision, and coagulation across multiple specialties including urology (BPH, tumors, lithotripsy), orthopaedics/arthroscopy (meniscectomy, discectomy), general surgery, ENT, gynecology, gastroenterology, thoracic/pulmonary, dermatology, podiatry, neurosurgery, and ophthalmology. Specific patient criteria apply for lumbar discectomy (e.g., unilateral leg pain, positive CT/MRI, failed conservative therapy).
Regulatory Classification
Identification
(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
Predicate Devices
Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers (K980685, K933318)
Coherent ULTRAPULSE S Series Carbon Dioxide Surgical Lasers (K974789)
TTI Medical Accu-Beam Fiber Optic Handpiece (K952006)
Submission Summary (Full Text)
{0}------------------------------------------------
K 990947
4/24/97
Attachment 14 510(k) Summary Statement for the Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories
March 19, 1999
#### General Information I.
Coherent Medical Group Submitter: 2400 Condensa Street Santa Clara, California, U. S. A. 95051-0901 Michelle P. Deeton Contact Person:
Summary Preparation Date:
- II. Names
Device Names:
Select Single Modified Coherent VersaPulse Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and compatible fiber optic laser delivery devices with accessories (sterilization trays)
Primary Classification Name: Laser Powered Surgical Instrument (and Accessories)
## III. Predicate Devices
- Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers (K980685, K933318);
- Coherent VersaPulse Single Wavelength (Ho:YAG) and Coherent Ho:YAG Surgical Lasers (K932981, K923575, K914991, K914136, K910037, K902990, K895518);
- Coherent SlimLine Single Lumen Aspiration Needle Kit - Sterilization Tray-(K960413);
- Coherent ULTRAPULSE S Series Carbon Dioxide Surgical Lasers (K974789); .
- TTI Medical Accu-Beam Fiber Optic Handpiece (K952006). .
## IV. Product Description
The Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers that are the subject of this Premarket Notification 510(k) submission are comprised of the following functional components:
- . a laser console;
- control and display panel;
{1}------------------------------------------------
- a fiber port for delivery systems; .
- system microprocessor control electronics; ●
- a covered footswitch or handswitch; ●
- operating software; ●
- an optional remote control unit; ●
- a variety of fiber optic delivery devices with accessories (described below). .
The Coherent Delivery Devices that are the subject of this Premarket Notification 510(k) submission are comprised of all or some (depending on the product configuration) of the following functional components:
- laser connector; ●
- handpiece;
- probe tube;
- probe tip;
- fiber optic cable.
The Coherent Accessories (sterilization trays) are comprised of the following functional components:
- tray lid and tray bottom;
- latches; ●
- instrument supports. ●
#### Indications for Use . V.
The Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers (and their delivery accessories) are intended for use in surgical procedures involving open, laproscopic and endoscopic ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including:
- Ho:YAG - urology; urinary lithotripsy; arthroscopy; discectomy; endonasal surgery; gynecological surgical; and general surgery; and
- Nd:YAG - urology; general surgery; gastroenterology; thoracic and pulmonary surgery; ENT surgery; podiatry; orthopaedics; and with limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy.
The modified and the currently marketed Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers (and the delivery accessories that are used with them to deliver laser energy) are indicated for use in the performance of specific surgical applications in urology, urinary lithotripsy, arthroscopy/orthopaedics, discectomy, endonasal surgery/ENT surgery, gynecological surgery/gynecology, general surgery, gastroenterology, thoracic and pulmonary surgery, dermatology and plastic surgery, podiatry, and limited indications in gynecology, neurosurgery, ophthalmology, and lumbar discectomy as follows:
{2}------------------------------------------------
Ho:YAG - Urology
- · Endoscopic holmium laser resection of the prostate (HoLRP) with the VersaPulse Select Ho:YAG and Ho:YAG/Nd:YAG Surgical Lasers for treatment of benign prostatic hypertrophy (BPH).
# Ho:YAG - Urology - Continued
- Open and endoscopic urological surgery (ablation, vaporization, incision, excision and coagulation of soft tissue) including treatment of:
- bladder;
- urethral and ureteral tumors;
- condylomas;
- lesions of external genitalia;
- urethral and penile hemangioma;
- urethral strictures;
- bladder neck obstructions.
- · Urinary Lithotripsy including:
- endoscopic fragmentation of urinary calculi in the ureter or ureteropelvic junction;
- treatment of distal impacted fragments of steinstrasse when guide wires cannot be passed.
# Nd:YAG - Urology
- · Urological surgery (ablation, vaporization, incision, excision and coagulation of soft tissue) including:
- removal of superficial bladder tumors;
- removal of invasive bladder carcinoma;
- removal of benign or malignant lesions of the external genitalia, including condylomas;
- treatment of urethral strictures;
- treatment of vascularities of the bladder wall;
- prostatectomy.
# Ho:YAG - Arthroscopic Surgery / Arthroscopy
- · Arthroscopy (ablation, excision and coagulation of soft tissue) in various joints of the body, excluding the spine, including:
- meniscectomy;
- plica removal;
- ligament and tendon release;
- contouring and sculpting of articular surfaces;
- debridement of inflamed synovial tissue.
- · Discectomy including:
- percutaneous vaporization of the L4-5 and L5-S1 lumbar discs of the vertebral spine;
- open and arthroscopic spine procedures.
# Nd:YAG - Orthopaedic Surgery
- · Arthroscopy (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
Knee
- capsulectomy in the knee;
{3}------------------------------------------------
- chondroplasty in the knee;
- plica removal in the knee;
- lateral ligament release in the knee;
- meniscectomy in the knee;
- synovectomy in the knee;
- osteoarthritic lesion removal in the knee;
## Shoulder
- coracoacromial release in the shoulder;
- debridement of scar tissue in the shoulder;
- adhesive capsule release in the shoulder;
- labral tear repair in the shoulder;
- synovectomy in the shoulder.
- · Discectomy (limited to open, percutaneous and arthroscopic vaporization of the L4-5 and L5-S1 lumbar discs of the vertebral spine in patients with):
- unilateral leg pain greater than back pain;
- paresthetic discomfort in a specific dermatomal distribution;
- positive straight leg raising test and/or positive bowstring sign;
- possible neurologic finding including wasting, weakness, sensory alteration and reflex alteration;
- no improvement after at least 6 weeks of conservative therapy;
- positive CT or MRI showing a subligamentous herniation at the location consistent with clinical findings.
## Ho:YAG - General Surgery
- · Open, laparoscopic, and endoscopic general surgery (vaporization, ablation, incision, and coagulation of soft tissue) including:
- cholecystectomy;
- lysis of adhesions;
- appendectomy;
- removal of benign and malignant lesions;
- biopsy, pylorostenotomy, and removal of polyps of the sigmoid colon.
# Nd:YAG - General Surgery
- · Open, laparoscopic, and endoscopic general surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- cholecystectomy;
- mastectomy;
- hepatectomy;
- pancreatectomy;
- splenectomy;
- hemorrhoidectomy;
- thyroidectomy;
- parathyroidectomy;
- herniorrhaphy;
- tonsillectomy;
- appendectomy;
- lymphadenectomy;
- partial nephrectomy;
{4}------------------------------------------------
- pilonidal cystectomy;
- resection of lipoma;
- pelvic adhesiolysis;
- removal of lesions;
- removal of polyps;
- removal of tumors;
- tumor biopsy;
- debridement of decubitus ulcers.
## Ho:YAG - Endonasal Surgery
- Endoscopic endonasal surgery (ablation, vaporization, incision, and coagulation of soft tissue and cartilage) including:
- partial turbinectomy;
- ethmoidectomy;
- polypectomy;
- maxillary antrostomy;
- frontal sinusotomy;
- sphenoidotomy.
## Nd:YAG - Ear, Nose and Throat (ENT) Surgery
- · Endonasal surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- lesions or tumors of the oral, nasal, glossal, pharyngeal and laryngeal tissues;
- tonsillectomy;
- adenoidectomy.
# Ho:YAG - Gynecological Surgery
- · Open and laparoscopic gynecological surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue).
## Nd:YAG - Gynecological Surgery
- · Gynecological surgery limited to:
- treatment of menorrhagia by the photocoagulation, vaporization, or ablation, of the endometrial lining of the uterus under direct hysteroscopic visualization;
- intra-uterine treatment of submucous fibroids, benign endometrial polyps, and uterine septum by incision, excision, ablation, and/or vessel coagulation;
- intra-abdominal treatment of endometriosis and/or peritoneal adhesions with laser contact tips;
- soft tissue excisional procedures such as excisional conization of the cervix.
## Nd:YAG - Gastroenterologic Surgery
- · Gastroenterologic surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- partial removal of neoplastic tissue in the management of esophageal obstruction for symptomatic relief of dysphagia;
- gastrointestinal hemostasis including, varicies, esophagitis, esophageal ulcer, - Mallory-Wiess tear, gastric ulcer, angiodysplasia, stomal ulcers, non-bleeding ulcers, and gastric erosions;
- gastrointestinal tissue ablation of benign and malignant neoplasm, hemorrhoids and polyps.
{5}------------------------------------------------
# Nd:YAG - Thoracic and Pulmonary Surgery
- · Thoracic and pulmonary surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including treatment of:
- laryngeal lesions;
- airway obstructions including carcinoma;
- polyps and granulomas;
- palliation of obstructing carcinomas of the tracheobronchial tree.
# Nd:YAG - Dermatology and Plastic Surgery
- · Dermatology and plastic surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- lesions of skin and subcutaneous tissue;
- telangiectasia;
- port wine lesions;
- spider veins;
- hemangiomas;
- plantar warts;
- periungual and subungual warts;
- removal of tattoos;
- debridement of decubitus ulcer;
- treatment of keloids.
# Nd:YAG - Podiatry
- · Podiatry (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- matrixectomy;
- plantar warts;
- neuromas;
- periungual and subungual warts;
- radical nail excision.
# Nd:YAG - Neurosurgery
- · Neurosurgery limited to:
- hemostasis in neurosurgery procedures such as excision of brain lesions, spinal cord lesions, cranial nerves, peripheral nerves, and pituitary glands.
# Nd:YAG - Ophthalmology
- · Ophthalmology limited to:
- post-vitrectomy photocoagulation.
### VI. Rationale for Substantial Equivalence
The Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers share the same indications for use, similar design features, functional features, and therefore are substantially equivalent to the Coherent VersaPulse Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers (K980685, K933318) and the Coherent VersaPulse Single Wavelength (Ho:YAG) and Coherent Ho:YAG Surgical Lasers (K932981, K923575, K914991, K914136, K910037, K902990, K895518). The
{6}------------------------------------------------
operating platform in the Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers is also substantially equivalent to the operating platform in the Coherent ULTRAPULSE S Series Carbon Dioxide Surgical Lasers (K974789). The Coherent Delivery Devices are substantially equivalent to the previously cleared Coherent ( K933318, K923575, K914991, K910037, K902990 and K895518) and TTI Medical (K952006) delivery devices. The Coherent Accessories (sterilization trays) are substantially equivalent to the sterilization tray in the Coherent SlimLine Single Lumen Aspiration Needle Kit (K960413).
#### Safety and Effectiveness Information VII.
Safety and effectiveness information was provided to demonstrate that the Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories are safe and effective, when indicated for use for general and specific applications in the medical specialties of urology; urinary lithotripsy; arthroscopy; discectomy; endonasal surgery; gynecological; and general surgery; for Ho:YAG and urology; general surgery; gastroenterology; thoracic and pulmonary surgery; ENT surgery; podiatry; orthopaedics; and with limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy for Nd:YAG.
#### VIII. Conclusion
The Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories were found to be substantially equivalent to similar currently marketed and predicate surgical lasers, delivery devices and accessories.
The Modified Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories share the same indications for use, similar design features, and similar functional features as the currently marketed Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers and Delivery Devices with Accessories.
{7}------------------------------------------------
Image /page/7/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized image of an eagle with three lines representing its body and wings. The logo is surrounded by the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" in a circular arrangement.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
APR 2 7 1999
Ms. Michelle P. Deeton Senior Regulatory Affairs Associate Coherent Medical Group 2400 Condensa Street Santa Clara, California 95051-0901
K990947 Re:
Trade Name: Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery Devices with Accessories
Regulatory Class: II Product Code: GEX Dated: March 19, 1999 Received: March 22, 1999
Dear Ms. Deeton:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{8}------------------------------------------------
# Page 2 – Ms. Michelle P. Deeton
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of vour device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Colin McWilliams, Ph.D., M.D.
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{9}------------------------------------------------
| 510(k) Number (if known): | K990947 |
|---------------------------|------------------------------------------------------------------|
| Device Name : | Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and |
| | Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery |
| | Devices with Accessories |
Indications For Use:
The modified and currently marketed Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers are intended for use in surgical procedures involving open, laparoscopic and endoscopic ablation, vaporization, excision, incision, and coagulation of soft tissue in medical specialties including:
- Ho:YAG urology; urinary lithotripsy; arthroscopy; discectomy; endonasal surgery; ● gynecological surgery; and general surgery; and
- Nd:YAG urology; general surgery; gastroenterology; thoracic and pulmonary . surgery; ENT surgery; podiatry; orthopaedics; and with limited indications in gynecology; neurosurgery; ophthalmology; and lumbar discectomy.
The modified and currently marketed Coherent VersaPulse Select Single Wavelength (Ho:YAG) and Dual Wavelength (Ho:YAG/Nd:YAG) Surgical Lasers (and the delivery accessories that are used with them to deliver laser energy) are indicated for use in the performance of specific surgical applications in urology, urinary lithotripsy, arthroscopy/orthopaedics, discectomy, endonasal surgery/ENT surgery, gynecological surgery/gynecology, general surgery, gastroenterology, thoracic and pulmonary surgery, dermatology and plastic surgery, podiatry, and limited indications in gynecology, neurosurgery, ophthalmology, and lumbar discectomy as follows:
Ho:YAG - Urology
- · Endoscopic holmium laser resection of the prostate (HoLRP) with the VersaPulse Select Ho:YAG and Ho:YAG/Nd:YAG Surgical Lasers for treatment of benign prostatic hypertrophy (BPH)
*** Indications For Use Continued on Next Page (6 pages total) ***
(PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE
Prescription Use
(Per 21 CFR 801.109)
(Division Sign-Off)
Division of General Restorative Devices
510(k) Number K990947
Prescription Use (Per 21 CFR 801.109) OR
Over-The-Counter Use (Optional Format 1-2-96)
510(k) Modified VersaPulse Select and Delivery Devices with Accessories
Attachment 4 - Page 1
{10}------------------------------------------------
510(k) Number (if known):
Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and Device Name :__ Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery
- Devices with Accessories
Indications For Use Continued:
## Ho:YAG - Urology - Continued
- Open and endoscopic urological surgery (ablation, vaporization, incision, excision . and coagulation of soft tissue) including treatment of:
- bladder; t
-
- urethral and ureteral tumors;
- condylomas; -
- lesions of external genitalia; -
- urethral and penile hemangioma; 1
- urethral strictures; -
- bladder neck obstructions. -
- Urinary Lithotripsy including:
- endoscopic fragmentation of urinary calculi in the ureter or ureteropelvic ﮯ junction;
- treatment of distal impacted fragments of steinstrasse when guide wires cannot be passed.
## Nd:YAG - Urology
- Urological surgery (ablation, vaporization, incision, excision and coagulation of soft ● tissue) including:
- removal of superficial bladder tumors; -
- removal of invasive bladder carcinoma; t
- removal of benign or malignant lesions of the external genitalia, including condylomas;
- treatment of urethral strictures; t
- treatment of vascularities of the bladder wall; -
- prostatectomy. 1
## Ho:YAG - Arthroscopic Surgery/Arthroscopy
- Arthroscopy (ablation, excision and coagulation of soft tissue) in yarious joints of the body, excluding the spine, including:
- meniscectomy; -
- plica removal;
- ligament and tendon release;
- contouring and sculpting of articular surfaced wisson of General Restora
- 510(k) Number _ debridement of inflamed synovial tissue.
Prescription Use (Per 21 CFR 801.109)
●
## *** Indications For Use Continued on Next Page (page 2 of 6) ***
(Division Sign-Off)
{11}------------------------------------------------
510(k) Number (if known):
Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and Device Name :
- Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery
- Devices with Accessories
Indications For Use Continued:
- Discectomy including: .
- percutaneous vaporization of the L4-5 and L5-S1 lumbar discs of the vertebral spine;
- open and arthroscopic spine procedures.
# Nd:YAG - Orthopaedic Surgery
- Arthroscopy (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
Knee
-
●
- capsulectomy in the knee; -
- chondroplasty in the knee; ﺳ
- plica removal in the knee; -
- lateral ligament release in the knee; -
- meniscectomy in the knee; -
- synovectomy in the knee; -
- osteoarthritic lesion removal in the knee; .
# Shoulder
- coracoacromial release in the shoulder; -
- debridement of scar tissue in the shoulder; -
- adhesive capsule release in the shoulder; -
- labral tear repair in the shoulder; -
- synovectomy in the shoulder. -
- Discectomy:
- limited to open, percutaneous and arthroscopic vaporization of the L4-5 and 1
- L5-S1 lumbar discs of the vertebral spine in patients with:
- unilateral leg pain greater than back pain; .
- paresthetic discomfort in a specific dermatomal distribution; .
- . positive straight leg raising test and/or positive bowstring sign;
- possible neurologic finding including wasting, weakness, sensory ● alteration and reflex alteration;
- no improvement after at least 6 weeks of conservative therapy; ●
- positive CT or MRI showing a subligamentous herniation at the location ● consistent with clinical findings.
# Ho:YAG - General Surgery
.
- Open, laparoscopic, and endoscopic general surgery (vaporization, ablation, incision, and coagulation of soft tissue) including:
- cholecystectomy; -
- lysis of adhesions; -
- *** Indications For Use Continued on Next Page (page 3 of 6) ***
DC
(Division Sign-Off)
Division of General Restorative Devices
Division of General Restorative 510(k) Number
Prescription Use
(Per 21 CFR 801.109)
{12}------------------------------------------------
510(k) Number (if known):_____________________________________________________________________________________________________________________________________________________
| Device Name : | Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and<br>Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery |
|---------------|--------------------------------------------------------------------------------------------------------------------------------|
|---------------|--------------------------------------------------------------------------------------------------------------------------------|
- Devices with Accessories
Indications For Use Continued:
- appendectomy; ﮯ
- removal of benign and malignant lesions; ﮯ
- biopsy, pylorostenotomy, and removal of polyps of the sigmoid colon. -
## Nd:YAG - General Surgery
- Open, laparoscopic, and endoscopic general surgery (ablation, vaporization, . incision, excision, and coagulation of soft tissue) including:
- cholecystectomy; -
- mastectomy; -
- hepatectomy; -
- pancreatectomy; -
- splenectomy; -
- hemorrhoidectomy;
- thyroidectomy;
- parathyroidectomy;
- herniorrhaphy;
- tonsillectomy;
- appendectomy;
- lymphadenectomy;
- partial nephrectomy;
- pilonidal cystectomy;
- resection of lipoma;
- pelvic adhesiolysis;
- removal of lesions;
- removal of polyps;
- removal of tumors;
- tumor biopsy;
- debridement of decubitus ulcers. "
## Ho:YAG - Endonasal Surgery
- Endoscopic endonasal surgery (ablation, vaporization, incision, and coagulation of ● soft tissue and cartilage) including:
- partial turbinectomy;
- ethmoidectomy; ﺖ
- polypectomy; -
- maxillary antrostomy; -
- frontal sinusotomy; -
- sphenoidotomy. =
Doello
(Division Sign-Off) Division of General Restorative Devices 9091 510(k) Number
Prescription Use
(Per 21 CFR 801.109)
*** Indications For Use Continued on Next Page (page 4 of 6) ***
{13}------------------------------------------------
510(k) Number (if known):
Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and Device Name :
- Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery
- Devices with Accessories
Indications For Use Continued:
## Nd: YAG - Ear, Nose and Throat (ENT) Surgery
- Endonasal surgery (ablation, vaporization, incision, excision, and coagulation of . soft tissue) including:
- lesions or tumors of the oral, nasal, glossal, pharyngeal and laryngeal tissues;
- tonsillectomy; -
- adenoidectomy. t
Ho:YAG - Gynecological Surgery
- Open and laparoscopic gynecological surgery (ablation, vaporization, incision, ● excision, and coagulation of soft tissue).
Nd:YAG - Gynecological Surgery
- Gynecological surgery limited to:
- treatment of menorrhagia by the photocoagulation, vaporization, or ablation, of the endometrial lining of the uterus under direct hysteroscopic visualization;
- intra-uterine treatment of submucous fibroids, benign endometrial polyps, and uterine septum by incision, excision, ablation, and/or vessel coagulation;
- intra-abdominal treatment of endometriosis and/or peritoneal adhesions with laser contact tips;
- soft tissue excisional procedures such as excisional conization of the cervix.
# Nd:YAG - Gastroenterologic Surgery
.
- Gastroenterologic surgery (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:
- partial removal of neoplastic tissue in the management of esophageal obstruction for symptomatic relief of dysphagia;
- gastrointestinal hemostasis including, varicies, esophagitis, esophageal . ulcer, Mallory-Wiess tear, gastric ulcer, angiodysplasia, stomal ulcers, nonbleeding ulcers, and gastric erosions;
- gastrointestinal tissue ablation of benign and malignap(t neoplasm, hemorrhoids and polyps.
**Prescription Use**
(Per 21 CFR 801.109)
(Division Sign-Off) Division of General Restorative Device 510(k) Number
*** Indications For Use Continued on Next Page (page 5 of 6) ***
{14}------------------------------------------------
510(k) Number (if known):
Modified Coherent VersaPulse Select Single Wavelength Ho:YAG and Device Name :_________________________________________________________________________________________________________________________________________________________________
- Dual Wavelength Ho:YAG/Nd:YAG Surgical Lasers and Delivery
- Devices with Accessories
Indications For Use Continued:
Nd:YAG - Thoracic and Pulmonary Surgery
- Thoracic and pulmonary surgery (ablation, vaporization, incision, excision, and . coagulation of soft tissue) including treatment of:
- laryngeal lesions; -
- airway obstructions including carcinoma; ﺘ
- polyps and granulomas; -
- palliation of obstructing carcinomas of the tracheobronchial tree. =
Nd:YAG - Dermatology and Plastic Surgery
- Dermatology and plastic surgery (ablation, vaporization, incision, excision, and . coagulation of soft tissue) including:
- lesions of skin and subcutaneous tissue; -
- telangiectasia; -
- port wine lesions; -
- spider veins; -
- hemangiomas; -
- plantar warts;
- periungual and subungual warts;
- removal of tattoos;
- debridement of decubitus ulcer;
- treatment of keloids. -
### Nd:YAG - Podiatry
- Podiatry (ablation, vaporization, incision, excision, and coagulation of soft tissue) . including:
- matrixectomy; -
- plantar warts; -
- neuromas;
- periungual and subungual warts; =
- ﺖ radical nail excision.
Division Sign-Off)
of general Restorative Devices.
n. sun ber .
### Nd:YAG - Neurosurgery
-
.
.
- Neurosurgery limited to:
- hemostasis in neurosurgery procedures such as excision of brain lesions, spinal cord lesions, cranial nerves, peripheral nerves, and pituitary glands.
### Nd:YAG - Ophthalmology
- Ophthalmology limited to:
- post-vitrectomy photocoagulation. l ***(page 6 of 6) ***
Prescription Use (Per 21 CFR 801.109)
510(k) Modified VersaPulse Select and Delivery Devices with Accessories
Attachment 4 - Page 6
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.