Biowy Multi-Chamber Freezing Bag

BK251308 · Biowy Corporation Lake Forest, CA 92630 · LPZ · Mar 17, 2026

Device Facts

Record IDBK251308
Device NameBiowy Multi-Chamber Freezing Bag
ApplicantBiowy Corporation Lake Forest, CA 92630
Product CodeLPZ
Decision DateMar 17, 2026
DecisionSESE
Device ClassClass U

Indications for Use

The Biowy Freezing Bag Set is intended for a single sequence of freezing, storage (in Liquid Nitrogen (-196°C)), and subsequent thawing (at +37°C) of hematopoietic progenitor cells.

Device Story

Sterile, flexible, multi-chamber plastic container system; used for cryopreservation of hematopoietic progenitor cells. System includes freezing bag, transfer/process bag, supernatant collecting bag, extension tubing, and connectors. Operates by containing cells during liquid nitrogen storage (-196°C) and subsequent thawing (+37°C). Used in clinical or laboratory settings by trained personnel. Provides a closed system for processing and storage; maintains cell viability during freeze-thaw cycles.

Clinical Evidence

Bench testing only. Verification included mechanical strength, biocompatibility, and durability studies during liquid nitrogen freeze/thaw cycles.

Technological Characteristics

Materials: EVA (freezing bag), PVC, ABS, PP (tubing/connectors), PVC (accessory bags). Form factor: Multi-chamber flexible container with integrated tubing and accessory bags. Capacity: 10-35ml. Sterilization: Sterile. Energy source: None (passive storage).

Indications for Use

Indicated for the freezing, storage, and thawing of hematopoietic progenitor cells.

Predicate Devices

Submission Summary (Full Text)

{0} # Special 510(k) ## 510(k) Summary 510(k) Owner: Biowy Corporation 27031 Vista Terrace Lake Forest, California 92630 Telephone No. 1-949-305-8211 Primary Contact: Arthur Lu Biowy Corporation Telephone: 1-949-305-8211 Fax: 1-866-506-5094 Email: alu@biowy.com Date prepared: March 30, 2026 Device name: Trade name: Biowy Multi-Chamber Freezing Bag Set Common Name: Freezing Bag Classification name: Container, Frozen Donor Tissue Storage FDA Product Code: LPZ Classification: Unclassified Predicate Device: Biowy Multi-Chamber Freezing Bag (BK251308) Device Description: The Biowy multi-chamber freezing bag set is a sterile plastic flexible container intended only for a single sequence of freezing, storage (in Liquid Nitrogen (-196°C)), and subsequent thawing (at +37°C) of hematopoietic progenitor cells. The freezing bag product is comprised of a multi-chamber freezing bag with twist-off ports, extension tubing and connectors with a transfer/process bag and a supernatant collecting bag. Indications for Use: The Biowy Freezing Bag Set is intended for a single sequence of freezing, storage (in Liquid Nitrogen (-196°C)), and subsequent thawing (at +37°C) of hematopoietic progenitor cells. ### Technical Characteristics The Biowy Multi-Chamber Freezing Bag Set is substantially equivalent to the predicate in indications for use, design, technology/principal of operation, materials and performance. Differences between the devices do not raise any significant issues of safety and effectiveness. | | **Predicate** | **Subject Device** | | --- | --- | --- | | | **Biowy Multi-Chamber Freezing Bag (BK251308)** | **Biowy Multi-Chamber Freezing Bag Set** | | **Indications for Use** | The Biowy Freezing Bags are intended for a single sequence of freezing, storage (in Liquid Nitrogen (-196°C)), and subsequent thawing (at +37°C) of hematopoietic progenitor cells. | The Biowy Multi-Chamber Freezing Bags are intended for a single sequence of freezing, storage (in Liquid Nitrogen (-196°C)), and subsequent thawing (at +37°C) of hematopoietic progenitor cells. | | Specimen | Hematopoietic progenitor cells | Same as the predicate | | Materials | Freezing bag: EVA | Freezing bag: EVA (same as the predicate) | {1} | | Accessory bag: Mixing bag (EVA) Extension tubing/connectors: PVC, ABS, PP | Accessory bags: Transfer/process bag and supernatant collecting bag (PVC, different from the predicate) Extension tubing/connectors: PVC, ABS, PP (same as the predicate) | | --- | --- | --- | | Design | A sterile multi-chamber EVA freezing bag with integrated tubing and a mixing bag. | A sterile multi-chamber EVA freezing bag with integrated tubing, a transfer/process bag and a supernatant collecting bag. | | Freeze capacity | 10-35ml | 10-35ml | **Nonclinical Performance Data:** Verification of device performance was established with acceptable results from the following non-clinical tests: mechanical strength, biocompatibility, durability in freeze/thaw studies in liquid nitrogen. **Conclusions:** The Biowy Multi-Chamber Freezing Bag Set is substantially equivalent to the predicate device.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...