OPC 3G ALL-CERAMIC SYSTEM, CORE AND OVERLAY PORCELAINS

K994435 · Jeneric/Pentron, Inc. · EIH · Feb 10, 2000 · Dental

Device Facts

Record IDK994435
Device NameOPC 3G ALL-CERAMIC SYSTEM, CORE AND OVERLAY PORCELAINS
ApplicantJeneric/Pentron, Inc.
Product CodeEIH · Dental
Decision DateFeb 10, 2000
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6660
Device ClassClass 2

Indications for Use

The OPC 3G All-Ceramic System, Core and Overlay Porcelains comprise a lithium disilicate glass-ceramic core used for all-ceramic dental restorations. Subsequent layers of porcelain are applied over top to provide additional aesthetics and characterizations. This system offers high strength, low wear, the aesthetics of a metal-free system, and better thermal shock properties due to the lower thermal expansion of the materials used. The dental restoration is prepared by a lost wax technique. The dental restorations are designed in a wax pattern and invested into refractory. The refractory is burned out to remove the wax and leave a cavity of the dental design. Pellets of 3G All-Ceramic are placed into the investment cavity and transferred to a hot pressing furnace where the investment/pellets are brought to a higher temperature. The temperature is maintained long enough for the glassceramic to become molten and then pressed into the cavity creating an exact duplicate of the original wax pattern. In addition, dental restorations can be made by forming the material into pre made blocks of ceramics, which are milled to the coping/bridge shape by CAD/CAM equipment. The OPC 3G All-Ceramic System, Core and Overlay Porcelains are intended for either hot pressing or CAD/CAM machining all-ceramic dental restorations. The OPC 3G All-Ceramic System, Core and Overlay Porcelains should be used with 3G All-Ceramic materials only and not intermixed with other manufacturers products/porcelains. The system is used for fabrication of dental restorations including inlays, onlays, veneers, single units, and anterior bridges up to the first premolar.

Device Story

Lithium disilicate glass-ceramic system for dental restorations; utilizes lost wax technique (wax pattern, refractory investment, hot pressing furnace) or CAD/CAM milling of pre-made ceramic blocks; system includes core pellets, stains, bodies, incisals, glazes, and associated laboratory accessories; used by dental professionals for fabrication of inlays, onlays, veneers, single units, and anterior bridges; provides metal-free aesthetics, high strength, and thermal shock resistance; output is a custom-fitted dental restoration.

Clinical Evidence

No clinical data provided; substantial equivalence based on material composition and functional similarity to predicate devices.

Technological Characteristics

Lithium disilicate glass-ceramic material; fabrication via hot pressing or CAD/CAM milling; system includes core pellets, stains, bodies, incisals, and glazes; non-electronic, mechanical/material-based dental system.

Indications for Use

Indicated for fabrication of all-ceramic dental restorations including inlays, onlays, veneers, single units, and anterior bridges up to the first premolar.

Regulatory Classification

Identification

Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K994435 ## 21.0 510(K) SUMMARY Submitter: Jeneric/Pentron, Inc. Address: 53 North Plains Industrial Road Wallingford. Connecticut 06492 Contact Tel: 203-265-7397 X619 Contact Fax: 203-265-7662 Contact Person: Annmarie Tenero ### Date Summary Prepared: May 26, 2000 The compositions for 3G All-Ceramic Core is similar to Finesse All-Ceramic Core, K971869, Dentsply International and Empress2 Core, K982616, Ivoclar North America, in both composition and function. I.ikewise, the 3G All Ceramic overlay used in conjunction with the 3G Core is also similar to the overlay porcclains for these same cores, Finesse Porcelain and Empress2 Porcclain. Because of these similarities to predicate devices, the material is substantially equivalent. The OPC 3G All-Ceramic System, Core and Overlay Porcelains comprise a lithium disilicate glassceramic core used for all-ceramic dental restorations. Subsequent layers of porcelain are applied over top to provide additional aesthetics and charactcrizations. This system offers high strength, low wear, the aesthetics of a metal-free system, and better thermal shock properties due to the lower thermal expansion of the materials used. The dental restoration is prepared by a lost wax technique. The dental restorations are designed in a wax pattern and invested into refractory. The refractory is burned out to remove the wax and leave a cavity of the dental design. Pellets of 3G All-Ceramic are placed into the investment cavity and transferred to a hot pressing furnace where the investment/pellets are brought to a higher temperature. The temperature is maintained long enough for the glass-ceramic to become molten and then pressed into the cavity creating an exact duplicate of the original wax pattern. In addition, dental restorations can be made by forming the material into pre made blocks of ceramics, which are milled to the coping/bridge shape by CAD/CAM cquipment. The OPC 3G All-Ceramic System is intended for either hot pressing or CAD/CAM machining allceramic dental restorations. The 3G All-Ceramic System should be used with 3G All-Ceramic materials only and not intermixed with other manufacturers products/porcelains. The system is used for fabrication of dental restorations inlays, onlays, veneers, single units, and anterior bridges up to the first premolar. The OPC 3G All-Ceramic System, Core and Overlay Porcelains will include Corc pcllcts, Corc Stains, Bodies, Incisals, Glazes, Investment, Investment Liquids, Acid Solutions (Shipped Separately), Acid Neutrilizers, Glaze Liquids, Disposable Plungers, Paper Rings, Plastic Scoops, MSDS and Instructions. {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features a stylized caduceus, a symbol often associated with medicine and healthcare, with three intertwined strands. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the caduceus. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 FEB 1 0 2000 Ms. Annmarie Tenero Jeneric®/Pentron® Incorporated 53 North Plains Industrial Road P.O. Box 724 Wallingford, Connecticut 06492-0724 K994435 Re : Trade Name: OPC 3G All-Ceramic System, Core and Overlay Porcelains Regulatory Class : II Product Code: EIH Dated: December 28, 1999 Received: December 30, 1999 Dear Ms. Tenero: We have reviewed your Section 510 (k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in Please note: this response to your the Federal Register. premarket notification submission does not affect any {2}------------------------------------------------ Page 2 - Ms. Tenero obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510 (k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4692. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, K. Walter Timothy A. Ulatowski Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ ## 5.0 INDICATION FOR USE STATEMENT # 510(k) NUMBER (IF KNOWN): K994435 #### DEVICE NAME: OPC 3G ALL-CERAMIC SYSTEM, CORE AND OVERLAY PORCELAINS. ## INDICATION FOR USE: The OPC 3G All-Ceramic System, Core and Overlay Porcelains comprise a lithium disilicate glass-ceramic core used for all-ceramic dental restorations. Subsequent layers of porcelain are applied over top to provide additional aesthetics and characterizations. This system offers high strength, low wear, the aesthetics of a metal-free system, and better thermal shock properties due to the lower thermal expansion of the materials used. The dental restoration is prepared by a lost wax technique. The dental restorations are designed in a wax pattern and invested into refractory. The refractory is burned out to remove the wax and leave a cavity of the dental design. Pellets of 3G All-Ceramic are placed into the investment cavity and transferred to a hot pressing furnace where the investment/pellets are brought to a higher temperature. The temperature is maintained long enough for the glassceramic to become molten and then pressed into the cavity creating an exact duplicate of the original wax pattern. In addition, dental restorations can be made by forming the material into pre made blocks of ceramics, which are milled to the coping/bridge shape by CAD/CAM equipment. The OPC 3G All-Ceramic System, Core and Overlay Porcelains are intended for either hot pressing or CAD/CAM machining all-ceramic dental restorations. The OPC 3G All-Ceramic System, Core and Overlay Porcelains should be used with 3G All-Ceramic materials only and not intermixed with other manufacturers products/porcelains. The system is used for fabrication of dental restorations including inlays, onlays, veneers, single units, and anterior SUSE Underges up to the first premolar ... (Division Sian-Off) Division of Dental, Infection Control, Division of Dental, Infection Control. and General Hospital Devices പ്രശ്ചാര്യം പ്രവ്യാപ്പ്യൂട്ട് 510(k) Number ______________________________________________________________ > (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED.) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use OR Over -The-Counter-Use (Per 21 CFR 801.109) (Optional Format 1-2-96) 5.0 Jeneric/Pentron, Inc. 510K Submission - OPC 3G ALL-CERAMIC SYSTEM, CORE AND OVERLAY PORCELAINS
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...