HARDYDISK MEZLOCILLIN 75MCG

K994212 · Hardy Diagnostics · JTN · Feb 15, 2000 · Microbiology

Device Facts

Record IDK994212
Device NameHARDYDISK MEZLOCILLIN 75MCG
ApplicantHardy Diagnostics
Product CodeJTN · Microbiology
Decision DateFeb 15, 2000
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 866.1620
Device ClassClass 2

Indications for Use

HardyDisk™ Antimicrobial Sensitivity Disks are used for semi-quantitative in vitro susceptibility testing by the agar diffusion test procedure (Kirby-Bauer) of rapidly growing and certain fastidious bacterial pathogens. Standardized methods for agar diffusion testing have been described for Enterobacteriaceae, Staphylococcus spp., Pseudomonas spp., Acinetobacter spp., Listeria monocytogenes, Enterococcus spp., other streptococci and, by modified procedures, Haemophilus influenzae, Neisseria gonorrhoeae and Streptococcus pneumoniae. HardyDisk™ Mezlocillin is indicated for in vitro activity against the Enterobacteriaciae, Pseudomonas aeruginosa and Acinetobacter spp.,

Device Story

HardyDisk™ Mezlocillin, 75mcg, is an antimicrobial susceptibility test disk used in clinical microbiology laboratories. The device consists of a paper disk impregnated with a specific concentration of the antibiotic mezlocillin. It is used in the Kirby-Bauer agar diffusion test procedure to determine the susceptibility of bacterial pathogens to the antibiotic. The disk is placed on an agar plate inoculated with the patient's bacterial isolate. As the antibiotic diffuses into the agar, it creates a zone of inhibition if the bacteria are susceptible. Laboratory professionals measure the diameter of this zone to categorize the organism as susceptible, intermediate, or resistant. This information assists clinicians in selecting appropriate antibiotic therapy for patients with bacterial infections.

Clinical Evidence

No clinical data provided; device relies on standardized in vitro agar diffusion (Kirby-Bauer) methodology for antimicrobial susceptibility testing.

Technological Characteristics

Antimicrobial susceptibility test disk; paper disk impregnated with 75mcg of mezlocillin; utilizes agar diffusion (Kirby-Bauer) principle; in vitro diagnostic use.

Indications for Use

Indicated for in vitro susceptibility testing of rapidly growing and certain fastidious bacterial pathogens, including Enterobacteriaceae, Pseudomonas aeruginosa, and Acinetobacter spp., using the Kirby-Bauer agar diffusion method.

Regulatory Classification

Identification

An antimicrobial susceptibility test disc is a device that consists of antimicrobic-impregnated paper discs used to measure by a disc-agar diffusion technique or a disc-broth elution technique the in vitro susceptibility of most clinically important bacterial pathogens to antimicrobial agents. In the disc-agar diffusion technique, bacterial susceptibility is ascertained by directly measuring the magnitude of a zone of bacterial inhibition around the disc on an agar surface. The disc-broth elution technique is associated with an automated rapid susceptibility test system and employs a fluid medium in which susceptibility is ascertained by photometrically measuring changes in bacterial growth resulting when antimicrobial material is eluted from the disc into the fluid medium. Test results are used to determine the antimicrobial agent of choice in the treatment of bacterial diseases.

Submission Summary (Full Text)

{0}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/0/Picture/1 description: The image shows a stylized graphic, possibly a logo or emblem. It features three parallel, curved lines that resemble abstract wings or waves. The lines are thick and black, creating a bold visual impact. The word "DEPARTMENT" is partially visible along the left edge of the image, oriented vertically. FEB 1 5 2000 Food and Drug Administration 2098 Gaither Road Rockville MD 20850 Ms. Melissa Traylor, RAC Technical Services Director/Regulatory Affairs Hardy Diagnostics, Inc. 1430 West McCoy Lane Santa Maria, California 93455 K994212 Re: Trade Name: HardyDisk™ Mezlocillin, 75mcg Regulatory Class: II Product Code: JTN Dated: December 8, 1999 Received: December 14, 1999 Dear Ms. Traylor: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {1}------------------------------------------------ Page 2 This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html". Sincerely yours, Steven Butman Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ Image /page/2/Picture/0 description: The image shows the logo for Hardy Diagnostics. The logo consists of a circular graphic on the left, followed by the text "HARDY" in large, bold letters. Below "HARDY" is the word "DIAGNOSTICS" in smaller letters. The circular graphic appears to be a stylized representation of a petri dish or a cell, with several curved lines inside. Frail: Sales@Hardydiannostics Com Santa Maria, California 1430 West McCoy Lane Santa Maria, CA 93455 Tel: (805) 346-2766 Fax. (805) 346-2760 Salt Lake City Ustat 254 W. Cottage Ave Sandy, UT 84070 Tel: 18001 995-4773 Fax: 18011562-3214 Phoenix Arizona Iron Ave #105 Mesa, AZ 85210 Tel: 18001 995-845 ## Indications for Use Statement-HardyDisk tm Mezlocillin, 75mcg f2.100/144482 HardyDisk™ Antimicrobial Sensitivity Disks are used for semi-quantitative in vitro susceptibility testing by the agar diffusion test procedure (Kirby-Bauer) of rapidly growing and certain fastidious bacterial pathogens. Standardized methods for agar diffusion testing have been described for Enterobacteriaceae, Staphylococcus spp., Pseudomonas spp., Acinetobacter spp., Listeria monocytogenes, Enterococcus spp., other streptococci and, by modified procedures, Haemophilus influenzae, Neisseria gonorrhoeae and Streptococcus pneumoniae. HardyDisk™ Mezlocillin is indicated for in vitro activity against the Enterobacteriaciae, Pseudomonas aeruginosa and Acinetobacter spp., <End> Concurrence of CDRH-ODE Woody Duboes 510(k) Number. Prescription Use (per 21 CFR 801.109) OR Over-the Counter-Use (Optional format 1-2-96)
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...