K993115 · Bonutti Research, Inc. · MAI · Dec 17, 1999 · Orthopedic
Device Facts
Record ID
K993115
Device Name
MULTITAK SS
Applicant
Bonutti Research, Inc.
Product Code
MAI · Orthopedic
Decision Date
Dec 17, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3030
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Multitak SS™ bone anchors are intended for use as load bearing or non-load bearing suture anchors in the attachment of soft tissue to bone in various orthopedic surgical procedures. The bone anchors are provided sterile and are intended for single use with suture up to USP Size No. 2. Multitak SS™ bone anchors are indicated for use in the following orthopedic soft tissue to bone fixation applications: Shoulder: Bankart lesion repairs S.L.A.P. lesions repairs Acromio-clavicular repairs Capsular shift/capsulolabral reconstruction Deltoid repairs Rotator cuff tear repairs Biceps tenodesis Biceps tendon reattachment Elbow: Tennis elbow repair Ulnar or radial collateral ligament reconstruction Extra-capsular repairs Knee: Medial collateral ligament repair Lateral collateral ligament repair Posterior oblique ligament repair Illiotibial band tenodesis Patellar tendon repair VMO advancement Joint capsule closure Medial/Lateral repairs/reconstructions Foot/Ankle: Achilles tendon repairs Midfoot and forefoot repairs Hallus valgus reconstruction Hand/Wrist: Collateral ligament repair (Gamekeeper's Thumb) Scapholunate ligament reconstruction Tendon transfers in phalanx Volar plate reconstruction
Device Story
Cylindrical human cortical bone anchor; 2:1 length-to-diameter ratio; attached to suture. Inserted into predrilled bone hole via disposable or reusable introduction device. Suture tensioning toggles/locks anchor in cancellous bone; curved needle secures soft tissue to bone. Used by orthopedic surgeons in clinical/OR settings. Provides mechanical fixation of soft tissue to bone; facilitates healing. Benefits include biocompatible allograft material; equivalent pullout strength to titanium/stainless steel predicates.
Clinical Evidence
Bench testing only. Performance testing compared pullout strengths and failure modes of cortical bone anchors against titanium predicate anchors, demonstrating statistical equivalence.
Technological Characteristics
Material: Allograft human cortical bone. Form factor: Cylindrical anchor, ~2:1 length-to-diameter ratio. Insertion: Threaded suture loaded on tip of disposable or reusable introduction device. Sterilization: Sterile. No software or electronic components.
Indications for Use
Indicated for orthopedic soft tissue-to-bone fixation in shoulder, elbow, knee, foot/ankle, and hand/wrist procedures. Applicable for patients requiring ligament, tendon, or capsule repair/reconstruction. Prescription use only.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
{0}------------------------------------------------
#### Bonutti Research, Inc. - Multitak SSTM Bone Anchor 510(k) Premarket Notification
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS
The following information is submitted in accordance with the requirements of 21 CFR 807.92:
Contact Person: Patrick Balsmann, MS, RAC, Manager, OA & Regulatory/Clinical Affairs Bonutti Research, Inc., P.O. Box 1367, Effingham, Illinois 62401 Phone: 217.342.3412, ext. 321
Date Prepared: September 13, 1999
Proprietary Name: Multitak SSTM Bone anchor
Common Name: Soft Tissue Anchor
Classification Name: Unclassified.
Device Description: Multitak SS™ bone anchors are cylindrical suture anchors with an overall ratio of approximately 2:1, length to diameter. The suture anchors are processed from human cortical bone and provided sterile and are intended for single use. The bone soft tissue anchors with attached suture are inserted into a predrilled bone hole site with a single use disposable or a reusable introduction device. The suture ends are pulled to engage cancellous bone and to toggle and lock the anchor in bony tissue. A curved needle attached to the suture end(s) is used to secure soft tissue to bone.
Intended Use: The Multitak SS™ bone anchors are intended for use as load bearing or non-load bearing suture anchors in the attachment of soft tissue to bone in various orthopedic surgical procedures. The bone anchors are provided sterile and are intended for single use with suture up to USP Size No. 2.
Multitak SS™ bone anchors are indicated for use in the following orthopedic soft tissue to bone fixation applications:
- Shoulder: Bankart lesion repairs S.L.A.P. lesions repairs Acromio-clavicular repairs Capsular shift/capsulolabral reconstruction Deltoid repairs Rotator cuff tear repairs Biceps tenodesis
{1}------------------------------------------------
#### Bonutti Research, Inc. - Multitak SSTM Bone Anchor 510(k) Summary of Safety and Effectiveness Page 2
- Biceps tendon reattachment Elbow: Tennis elbow repair Ulnar or radial collateral ligament reconstruction Extra-capsular repairs Knee: Medial collateral ligament repair Lateral collateral ligament repair Posterior oblique ligament repair Illiotibial band tenodesis Patellar tendon repair VMO advancement Joint capsule closure Medial/Lateral repairs/reconstructions Foot/Ankle: Achilles tendon repairs Midfoot and forefoot repairs Hallus valgus reconstruction Hand/Wrist: Collateral ligament repair (Gamekeeper's Thumb) Scapholunate ligament reconstruction Tendon transfers in phalanx Volar plate reconstruction
Predicate Device: The Multitak SS™ bone anchors are similar in intended use and design to Multitak SS™ titanium suture anchors (K973015.) The bone anchors method of insertion with disposable or reusable introduction devices is similar in design and materials to currently marketed Multitak SS™ introduction devices (K973015 and K934183.) Performance testing comparing the pullout strengths and failure modes of Multitak SSTM cortical bone anchors to titanium anchors demonstrated that the anchors were statistically equivalent.
Predicate Comparison: A chart comparing characteristics of the Multitak SS™ bone anchors to those of the predicate devices is attached.
Submitted by:
Stryker Baker
Patrick Balsmann Manager, QA & Regulatory/Clinical Affairs
{2}------------------------------------------------
# Bonutti Research, Inc. - Multitak SSTM Bone Anchor 510(k) Premarket Notification Substantial Equivalence Chart
| Device Characteristic | Multitak SSTM Bone Anchor | Multitak SSTM Titanium Anchor | Multitak SSTM Stainless Steel<br>Anchor |
|----------------------------|----------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------|
| 510(k) Number | Current Submission. | K973015. | K934183. |
| Intended Use | Orthopedic procedures involving<br>the attachment of soft tissue to<br>bone. | Orthopedic procedures involving<br>the attachment of soft tissue to<br>bone. | Orthopedic procedures involving<br>the attachment of soft tissue to<br>bone. |
| Indications For Use | Shoulder, elbow, knee, foot/ankle,<br>and hand/wrist soft tissue to bone<br>orthopedic procedures. | Shoulder, elbow, knee, foot/ankle,<br>and hand/wrist soft tissue to bone<br>orthopedic procedures. | Shoulder, elbow, knee, and<br>foot/ankle soft tissue to bone<br>orthopedic procedures. |
| Anchor Design | Cylindrical anchors approximate<br>ratio of 2:1 length to diameter. | Cylindrical anchors approximate<br>ratio of 2:1 length to diameter. | Tubular anchors approximate ratio<br>of 2:1 length to diameter. Single<br>and double anchor tube constructs. |
| Anchor Material | Allograft human cortical bone. | Titanium. | Stainless steel. |
| Anchor Insertion<br>Method | Anchor with threaded suture<br>loaded on to tip of disposable or<br>reusable introduction device. | Anchor with threaded suture<br>loaded on to tip of disposable<br>introduction device. | Anchor with threaded suture<br>loaded on to tip of reusable<br>introduction device. |
| Anchor Provided<br>Sterile | Sterile. | Sterile. | Sterile. |
| Anchor Packaging | One individual anchor preloaded<br>in disposable introduction device.<br>One individual anchor. | One individual anchor preloaded<br>in disposable introduction device. | One individual anchor preloaded<br>in disposable introduction device.<br>One individual anchor. |
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features a stylized caduceus, a symbol often associated with medicine and healthcare, with three intertwined snakes and a staff. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the caduceus.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC 1 7 1999
Mr. Patrick G. Balsmann, MS, RAC Manager, QA & Regulatory/Clinical Affairs Bonutti Research, Incorporated P.O. Box 1367 2600 South Raney Effingham, Illinois 62401
Re: K993115
Trade Name: Multitak SSTM Bone Anchor Regulatory Class: II Product Code: MAI and JDW Dated: September 17, 1999 Received: September 20, 1999
Dear Mr. Balsmann:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (OS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{4}------------------------------------------------
#### Page 2 - Mr. Patrick G. Balsmann, MS, RAC
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597, or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely vours.
hereely yours,
-ilme (l. H. Hage-
Xur James E. Dillard III Acting Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Bonutti Research, Inc. – Multitak SSTM Bone Anchor 510(k) Premarket Notification
### INDICATIONS FOR USE
Device Name: Multitak SSTM bone anchor.
Indications for Use: Multitak SS™ bone anchors are intended for use as a load bearing or nonload bearing suture anchor used in the attachment of soft tissue to bone in various orthopedic procedures.
Multitak SS™ bone anchors are indicated for use in the following orthopedic soft tissue to bone fixation applications:
| Shoulder: | Bankart lesion repairs |
|-------------|----------------------------------------------------|
| | S.L.A.P. lesions repairs |
| | Acromio-clavicular repairs |
| | Capsular shift/capsulolabral reconstruction |
| | Deltoid repairs |
| | Rotator cuff tear repairs |
| | Biceps tenodesis |
| Elbow: | Biceps tendon reattachment |
| | Tennis elbow repair |
| | Ulnar or radial collateral ligament reconstruction |
| Knee: | Extra-capsular repairs |
| | Medial collateral ligament repair |
| | Lateral collateral ligament repair |
| | Posterior oblique ligament repair |
| | Illiotibial band tenodesis |
| | Patellar tendon repair |
| | VMO advancement |
| | Joint capsule closure |
| Foot/Ankle: | Medial/Lateral repairs/reconstructions |
| | Achilles tendon repairs |
| | Midfoot and forefoot repairs |
| | Hallus valgus reconstruction |
| Hand/Wrist: | Collateral ligament repair (Gamekeeper's Thumb) |
| | Scapholunate ligament reconstruction |
| | Tendon transfers in phalanx |
| | Volar plate reconstruction |
Prescription Use *X*
(Per 21 CFR 801.109)
(Division Sign-Off)
Division of General Restorative Devices
510(k) Number K993115
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.