The Bi-Metric CoCr Head/Neck Replacement Hip Stem is intended for use in cases with a diagnoses of: a) Non-inflammatory degenerative joint disease, including osteoarthritis and avascular necrosis b) Rheumatoid arthritis c) Correction of functional deformities d) Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques e) Revisions of hip replacement components The Bi-Metric CoCr Head/Neck Replacement Hip Stem is intended for cemented application and is a single use device.
Device Story
Cobalt-chromium-molybdenum (Co-Cr-Mo) femoral hip stem; designed for cemented application; articulates with commercially available acetabular components. Features medial build-up for bone deficiency compensation; keel for load transfer to calcar region; lateral flange with suture holes for greater trochanter attachment. Stem surface grit-blasted; collar underside bead-blasted for improved stem/cement fixation. Available in three resection levels (34mm, 45mm, 55mm) and four diameters (9mm, 11mm, 13mm, 15mm); straight or bowed configurations. Used by orthopedic surgeons in clinical settings for hip arthroplasty. Single-use device.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Material: Cobalt-chromium-molybdenum (Co-Cr-Mo) alloy. Design: Femoral stem with medial build-up, keel, and suture holes. Surface treatment: Grit-blasted stem, bead-blasted collar. Dimensions: 34-55mm resection levels; 9-15mm diameters; straight or bowed. Application: Cemented. Single-use.
Indications for Use
Indicated for patients with non-inflammatory degenerative joint disease (osteoarthritis, avascular necrosis), rheumatoid arthritis, functional deformities, or proximal femur fractures (non-union, femoral neck, trochanteric) requiring hip replacement or revision.
Regulatory Classification
Identification
A hip joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and an acetabular resurfacing component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (§ 888.3027).
Predicate Devices
Bi-Metric CoCr Head/Neck Replacement Hip Stem (K955350)
Submission Summary (Full Text)
{0}------------------------------------------------
## K992058
1
## SUMMARY OF SAFETY AND EFFECTIVENESS
Biomet , Inc. Submitter: Airport Industrial Park P.O. Box 587 Warsaw, Indiana 4681-0587
Contact Person: Mary L. Verstynen
Product Code: 87JDI
Bi-Metric CoCr Head/Neck Replacement Hip Stems Device Name:
INTENDED USE: The Bi-Metric CoCr Head/Neck Replacement Hip Stem is
In the Bi-Metric Cock and consess of intended for use in cases with a diagnoses of:
- ded for use in cases with a diagnoses on.
a) Non-inflammatory degenerative joint disease, including osteoarthritis and avascular necrosis
- b) Rheumatoid arthritis
- c) Correction of functional deformities
- c) Correction of nunchonial delofinities
d) Treatment of non-union, femoral neck fracture, and trochanteric fractures of I reatment of non-unfon, remoral nock trav, inmanageable using other techniques
- e) Revisions of hip replacement components
The Bi-Metric CoCr Head/Neck Replacement Hip Stem is intended for cemented application and is a single use device.
DEVICE DESCRIPTION: The Bi-Metric CoCr Head/Neck Replacement Hip Stem
Comment of the first and ish in and ish is designed to articulate with a DEVICE DESCRIPTION. The Di-Moral stem which is designed to articulate with a
is a cobalt alloy (Co-Cr-Mo) femoral stem who it has no linkage across the ioint is a cobait anoy (Co-CI-MO) Temoral stom was It has no linkage across the joint.
commercially available acetabular component. It has no linkage across the femur in commercially available acclabular component "It is as semperate for bone of severe bone loss. The medial portion is built up to compensate for bone of severe bone foss. The medial portion is at , which allows transfer of the proximal
deficiencies. It is further enhanced by a keel, which There ene suture holes in the deficiencies. It is further cimanced by a novel forces. There are suture holes in the load to the calcal region, and resists tornemartaching and securing the greater iateral flange of the proximal platform for readed. The platformed. The platform trochanter in cases where a trochants oscoconty the scollar distally is "grit blasted"
inside the collar is "bead blasted"; the stem outside the consimproved fixation mside the conal IS "bead blasted", the clear or viding for an improved fixation between the stem/cement interface.
There are three resection levels: 34mm, 45mm, and 55mm with four diameters: 9mm, I here are three resection levels: 3-milli, 150mm, 200mm, 200mm, and 250mm
11mm, 13, and 15mm. The stems are available in 150mm, steres are boxec I Irmin, 15, and 1511m. The stems are straight and the 250mm stems are bowed right and left specific.
{1}------------------------------------------------
POTENTIAL RISKS: The potential risks associated with this device are the same as with any joint replacement. These include, but are limited to:
Fracture of the component Deformity of the joint Bone fracture Hematoma Implant loosening/migration Delayed wound healing Blood vessel damage Infection Breakdown of porous surface Soft tissue imbalance Metal sensitivity Nerve damage Cardiovascular disorders Tissue growth failure Excessive wear Dislocation
SUBSTANIAL EQUIVALENCE: The Bi-Metric CoCr Head/Neck Replacement Hip Stem is substantially equivalent to the following predicate device in terms of indications, intended use, design, and material.
Predicate device: Bi-Metric CoCr Head/Neck Replacement Hip Stem, K955350
000016
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal is circular and contains the department's name around the perimeter. In the center of the seal is a stylized image of three wavy lines, which are meant to represent the flow of people.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUL - 1 1999
Ms. Mary L. Verstynen Biomet, Inc. Airport Industrial Park P.O. Box 587 Warsaw, Indiana 46581-0587
K992058 Re:
Trade Name: Bi-Metric CoCr Head/Neck Replacement System Regulatory Class: II Product Code: JDI Dated: June 15, 1999 Received: June 18, 1999
Dear Ms. Verstynen:
We have reviewed your Section 510(k) notification of intent to market the device referenced we nave reviewed your Boonon 3 re(x) reasustantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the stated in the Energismer) to device Amendments, or to devices that have been reclassified in enacinem date of the Medical Dories I Level, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general therefore, manov the Act include requirements for annual registration, listing of devices, Controlis of the rest ree, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations (Fremarket Approvat), it may be subject to sacklerial resultations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to mopononist the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under scotions 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{3}------------------------------------------------
## Page 2 - Ms. Mary Verstynen
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
of Page
510(k) NUMBER (IF KNOWN): __ K992058
DEVICE NAME: Bi-Metric CoCr Head/Neck Replacement Hip Stem
INDICATIONS FOR USE:
The Bi-Metric CoCr Head/Neck Replacement IIip Stem is intended for use in cases with a diagnoses of:
- s Non-inflammatory degenerative joint disease, including osteoarthritis and avascular a) necrosis
- Rheumatoid arthritis b)
- Correction of functional deformities c)
- Correction of non-union, femoral neck fracture, and trochanteric fractures of the d) proximal femur with head involvement, unmanageable using other techniques
- Revisions of hip replacement components e)
The Bi-Metric CoCr Head/Neck Replacement Hip Stem is intended for cemented application and is a single use device.
## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.)
(Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use V (Per 21 CFR 801.109) OR
Over- The- Counter-(Optional Format 1-2 વ્વીર
(Optional Format 1-10)
(Division Sign-Off)
Division of General Restorative Devices
510(k) Number K99208
00004
3
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.