K992053 · Aesculap, Inc. · DXC · Jan 13, 2000 · Cardiovascular
Device Facts
Record ID
K992053
Device Name
AESCULAP VASCULAR INSTRUMENTS
Applicant
Aesculap, Inc.
Product Code
DXC · Cardiovascular
Decision Date
Jan 13, 2000
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.4450
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Aesculap's Vascular Clamps and Instruments are indicated for use in vascular surgery. Alfa and Alfa-mini vascular clamps are designed for temporary occlusion of blood vessels during open surgical procedures. Atraumatic vascular clamps and clamp appliers/removers are designed for temporary occlusion of blood vessels during either an open or endoscopic surgical approach. Laparoscopic vascular scissors, forceps, clamps, dissecting spatulas and needleholder are use for cutting, dissecting, clamping, fixation and suturing vessels and tubular structures. Flexible trocars provide access to the surgical site for use in laparoscopic vascular surgery.
Device Story
Aesculap Vascular Instruments comprise vascular clamps, flexible trocars, and endoscopic instruments (scissors, forceps, clamps, dissecting spatulas, needleholders). Devices used by surgeons in OR settings during open or laparoscopic vascular procedures. Clamps provide temporary vessel occlusion; endoscopic instruments facilitate cutting, dissecting, clamping, fixation, and suturing. Flexible trocars provide surgical site access. No automated processing or electronic output; purely mechanical surgical instrumentation.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Mechanical surgical instruments including vascular clamps, trocars, scissors, forceps, and needleholders. No energy source, software, or electronic components. Materials and design consistent with existing marketed vascular and endoscopic product lines.
Indications for Use
Indicated for patients undergoing vascular surgery, including open and endoscopic procedures, requiring temporary vessel occlusion, cutting, dissecting, clamping, fixation, or suturing of vessels and tubular structures.
Regulatory Classification
Identification
A vascular clamp is a surgical instrument used to occlude a blood vessel temporarily.
Reference Devices
Aesculap vascular and endoscopic devices
Codman vascular and endoscopic devices
Heartport vascular and endoscopic devices
Mueller vascular and endoscopic devices
Walter Lorenz vascular and endoscopic devices
Submission Summary (Full Text)
{0}------------------------------------------------
K992053
510(k) Premarket Notification
## Aesculap Vascular Instruments
Page 1 of 2
## 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS in Accordance with SMDA of 1990
# AESCULAP VASCULAR INSTRUMENTS
June 17. 1999
Contact
#### Company
Aesculap®, Inc.
1000 Gateway Blvd.
So. San Francisco, CA 94080
Mary Ellen Holden, Senior Requlatory Associate 650-624-5072 Phone: FAX: 650-589-3007
#### Trade Name
Aesculap Vascular Instruments
#### Common Name
Vascular Clamps, Endoscopic instruments, trocars
#### Classification Name and Product Code
Vascular Clamps Endoscope and Accessories 74DXC 78 KOG
## Product Classification
Class II
#### Requiatory Classification
21 CFR Section 876.1500 21 CFR Section 870.4450
Endoscope and Accessories Vascular Clamp
#### Intended Use
Aescular's Vascular Clamps and Instruments are indicated for use in vascular surgery. Alfa and Alfa-mini vascular clamps are designed for temporary occlusion of blood vessels during open surgical procedures. Atraumatic vascular clamps and clamp appliers/removers are designed for temporary occlusion of blood vessels during either an open or endoscopic surgical approach.
Laparoscopic vascular scissors, forceps, clamps, dissecting spatulas and needleholder are use for cutting, dissecting, clamping, fixation and suturing vessels and tubular structures. Flexible trocars provide access to the surqical site for use in laparoscopic vascular surgery.
(. (' 0 4
{1}------------------------------------------------
Page 2 of 2
005
#### 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS in Accordance with SMDA of 1990
## AESCULAP VASCULAR INSTRUMENTS
#### Device Description
The Vascular Instruments consist of vascular clamps, flexible trocars, and various endoscopic vascular instruments (scissors, forceps, clamps).
#### Summary of Technological Characteristics
Aesculap currently markets a complete vascular product line, which includes vascular clamps and instruments. In addition, Aesculap markets a complete endoscopic product line that includes endoscopes, flexible and rigid trocars, endoscopic clip appliers and endoscopic instruments such as forceps and scissors. The expanded line of Vascular Clamps and Endoscopic Vascular Instruments included in this submission do not impart any new technological characteristics. They use the same technology as current vascular and laparoscopic product lines - the only difference is the surgical application.
#### Performance Data
No applicable performance standards have been promulgated under Section 514 of the Food, Drug and Cosmetic Act for these devices.
#### Substantial Equivalence
Aesculap believes that the Vascular Instruments presented in this submission are substantially equivalent in design, function, and intended use to currently marketed vascular and endoscopic devices from companies such as:
- Aesculap .
- Codman .
- Heartport .
- Mueller .
- Walter Lorenz ●
{2}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes forming its wing, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged in a circular fashion around the eagle. The logo is in black and white and appears to be of moderate resolution.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JAN 1 3 2000
Ms. Mary Ellen Holden Senior Regulatory Associate Aesculap®, Inc. 1000 Gateway Blvd. So. San Francisco, CA 94080
K992053 Re : Aesculap Vascular Instruments Trade Name: Requlatory Class: II Product Code: DXC and GCJ October 14, 1999 Dated: October 15, 1999 Received:
Dear Ms. Holden:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation .
{3}------------------------------------------------
Page 2 - Ms. Mary Ellen Holden
you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4586. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on vour responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".
.gov, CA.IT, GO.MA, GO.MA.IT, IT.CM
Sincerely yours,
Chitopher for.
Celia M. Witten, Ph.D., M.D. Acting Director Division of Cardiovascular, Respiratory and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
510(k) Premarket Notification
Aesculap Vascular Instruments
Page 1 of 1
## INDICATION FOR USE STATEMENT
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------第一次 - 1998年
510(k) Number (if known):
K992c53
Device Name:
Aesculap Vascular Instruments
### Indication for Use:
Aesculap's Vascular Clamps and Instruments are indicated for use in vascular surgery. Alfa and Alfa-mini vascular clamps are designed for temporary occlusion of blood vessels during open surgical procedures. Atraumatic vascular clamps and clamp appliers/removers are designed for temporary occlusion of blood vessels during either an open or endoscopic surqical approach.
Laparoscopic vascular scissors, forceps, clamps, dissecting spatulas and needleholder are use for cutting, dissecting, clamping, fixation and suturing vessels and tubular structures. Flexible trocars provide access to the surgical site for use in laparoscopic vascular surgery.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
*Chit for Witten*
(Division Sign-Off)
Division of Cardiovascular, Respiratory,
and Neurological Devices
| 510(k) Number | K992053 |
|---------------|---------|
|---------------|---------|
| Prescription Use<br>(per 21 CFR 801.109) | X |
|------------------------------------------|---|
|------------------------------------------|---|
or
| Over-the-Counter Use | |
|----------------------|--|
|----------------------|--|
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.