← Product Code [GCT](/productcode/GCT) · K992050

# LUMENON XENON LIGHT SOURCE (K992050)

_Walter Lorenz Surgical, Inc. · GCT · Sep 14, 1999 · Gastroenterology, Urology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K992050

## Device Facts

- **Applicant:** Walter Lorenz Surgical, Inc.
- **Product Code:** [GCT](/productcode/GCT.md)
- **Decision Date:** Sep 14, 1999
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 876.1500
- **Device Class:** Class 2
- **Review Panel:** Gastroenterology, Urology

## Indications for Use

The Lumenon™ Xenon Light Source is intended to supply adjustable high intensity illumination for accessories such as headlights and endoscopes.

## Device Story

Lumenon Xenon Light Source is a fiberoptic illuminator providing high-intensity light for surgical headlights and endoscopes. Device features a universal turret with four receptacles for light cables, a quick-change lamp module, and two lamp life indicators. Principle of operation involves a Xenon Ceramic Short Arc Lamp producing 5600°K light, focused via a Plano Convex Lens into fiber optic cables. Intensity is manually adjusted (0-100%) using a graduated shutter attenuator knob on the front panel. Device includes integrated UV and IR filtration to reduce thermal and radiation output. Used in clinical/surgical environments by physicians or clinical staff. Output provides necessary visualization for endoscopic procedures; healthcare providers use this illumination to perform diagnostic or surgical tasks. Benefits include consistent, adjustable high-intensity lighting for improved visibility during procedures.

## Clinical Evidence

No clinical data. Bench testing only.

## Technological Characteristics

Fiberoptic illuminator; Xenon Ceramic Short Arc Lamp (5600°K); Plano Convex Lens; graduated shutter intensity control (0-100%); UV/IR filtration (glass window coating and IR filter); universal turret with 4 receptacles. Electrical safety compliance with IEC 601-1 and IEC 601-2-18. Requires hospital-grade grounding.

## Regulatory Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

## Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls:

1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following:
   1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures.
   2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use.
   3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use.
2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes.
3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches
4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error.
5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program.
(6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms.
(7) Labeling must include:
(i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified;
(ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA;
(iii) Identification of compatible devices;
(iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification;
(v) Reprocessing instructions for reusable components;
(vi) A shelf life for any sterile components;
(vii) A description of the device-specific use training program;
(viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and
(ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance.
(8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include:
(i) Device motion accuracy and repeatability;
(ii) System testing;
(iii) Instrument reliability;
(iv) Crosstalk;
(v) Table motion control;
(vi) Thermal effects on tissue;
(vii) User-device interface performance;
(viii) Workspace access testing; and
(ix) Performance testing with compatible devices.
(9) Software verification, validation, and hazard analysis must be performed.
(10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed.
(11) Performance data must demonstrate the sterility of all patient-contacting device components.
(12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life.
(13) Performance data must validate the reprocessing instructions for the reusable components of the device.
(14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible.
(15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic.
(16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information:
(i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and
(ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.

## Predicate Devices

- Welch Allyn Xenon 300 Light Source
- Xenon Light Source Model LS 6035

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

1/2

## Summary of Safety and Effectiveness

| Submitter Name and Address:  | Walter Lorenz Surgical, Inc<br>1520 Tradeport Drive<br>Jacksonville, FL 32218-2480 |
|------------------------------|------------------------------------------------------------------------------------|
| Contact Person and Telephone | Trevor Byrd<br>(904) 741-9455                                                      |

Device Name: Lumenon™ Xenon Light Source

Classification Name and Reference: Light Source, Endoscope, Xenon Arc

Intended Use: The Lumenon™ Xenon Light Source is intended to supply adjustable high intensity illumination for accessories such as headlights and endoscopes.

Detailed Device Description: The Lumenon™ Xenon Light Source is a fiberoptic illuminator for supplying high intensity illumination for accessories such as headlights and endoscopes. The device has a universal turret with four (4) receptacles to accept various light cables. It features a quick-change lamp module and two (2) lamp life indicators. The device incorporates a graduated shutter to attenuate the intensity of the light output, adjustable from 0 to 100 percent. The intensity control is adjusted by turning the attenuater knob located on the front panel The Lumenon™ Light Source utilizes a Plano Convex Lens for focusing light down to the diameter of the fiber optic cable. The 5600°K, light is produced by a Xenon Ceramic Short Arc Lamp. The visible output is 515 X 10(3) Candelas. The equivalent visible output in terms of Lux is 47,862 Lux. ORC coats the glass window of the xenon lamp in order to reduce UV output. The IR is reduced by a glass filter with an IR coating which blocks IR transmissions. UV output is 2.6 watts.

## Potential Risks:

- The Lumenon™ Xenon Light Source must not be used in the presence of flammable . anesthetics or other flammable gases due to the danger of possible explosion.
- High energy radiated light guided through endoscopes or fiber optics may produce . high temperatures in front of the light outlet and at the tip of the instrument.
- Verify that the tip of the instrument is not in excess of 41° C prior to use. .
- This product should be used only with type BF endoscopic instruments which have ● been certified according to IEC 601-1 for medical equipment and IEC 601-2-18 for endoscopic equipment.
- The lamp produces high intensity visible and ultraviolet radiation that may cause burns . to skin or eyes.
- Adequate cooling is required for proper operation of the unit. .
- Grounding reliability is achieved only when connected to a "Hospital-use" or . "Hospital-grade" receptacle.
- Disconnect the power cord before attempting any service to the Lumenon™ Xenon . Light Source
- The lamp is filled with xenon gas at very high pressure. Do not subject the lamp to . mechanical forces or rough handling, explosion may result.

{1}------------------------------------------------

Substantially Equivalent Device: The Lumenon™ Xenon Light Source is substantially equivalent to the Welch Allyn Xenon 300 Light Source, the Xenon Light Source Model LS 6035 and other legally marketed Xenon Light Sources in operational principles, and technological characteristics. Any difference between devices are minor and rise no new issues of safety and effectiveness.

ບບໍ່ປີ00002

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which is a staff with two snakes coiled around it, and the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged in a circle around the symbol. The logo is black and white.

## DEPARTMENT OF HEALTH & HUMAN SERVICES

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

SEP 1 4 1999

Mr. Trevor Byrd Requlatory Assistant Walter Lorenz Surgical, Inc. 1520 Tradeport Drive Jacksonville, FL 32218-2480

Dear Mr. Byrd:

Re: K992050 Lumenon Xenon Light Source Dated: August 18, 1999 Received: August 19, 1999 Regulatory Class: 11 21 CFR §876.1500/Procode: 78 GCT

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major requlations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent delermination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regult in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnosic devices), piease contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97): Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".

Sincerely yours,

CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

Page _1_ of _1_

・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・

## 510(k) Number (if known): K992050

Device Name: Lumenon Xenon Light Source

Indications For Use: The Lumenon Xenon Light Source is intended to supply adjustable high intensity illumination for accessories such as headlights and endoscopes.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription Use i (Per 21 FR 801.109)

OR

Over-The-Counter Use_

(Optional Format 1-2-96)

(Division Sign-Off) Division of Reproductive, Abdominal, ENT, and Radiological Devig 510(k) Number

---

**Source:** [https://fda-staging.innolitics.com/device/K992050](https://fda-staging.innolitics.com/device/K992050)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
