K990927 · Perry Baromedical Corp. · CBF · Nov 12, 1999 · Anesthesiology
Device Facts
Record ID
K990927
Device Name
SIGMA 3400 MONOPLACE HYPERBARIC CHAMBER
Applicant
Perry Baromedical Corp.
Product Code
CBF · Anesthesiology
Decision Date
Nov 12, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 868.5470
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The SIGMA I, SIGMA Plus and SIGMA 3400 chambers are used to provide Hyperbaric Oxygen Therapy, prescribed by a licensed physician, where medical grade oxygen is administered to patients while under pressure, by the patient breathing oxygen from the chamber atmosphere that is pressurized with pure oxygen. The breathing of oxygen at elevated pressure promotes the movement of oxygen into the patient's tissues.
Device Story
Monoplace hyperbaric chamber; provides hyperbaric oxygen therapy (HBOT) to single patient. Input: medical grade oxygen for chamber pressurization. Operation: patient breathes oxygen-enriched atmosphere at elevated pressure to promote tissue oxygenation. Control: fully pneumatic system; no electrical/electronic components. Features: ASME-certified pressure vessel; acrylic cylinder; intrinsically safe communication system. Usage: clinical setting; prescribed by physician. Output: pressurized oxygen environment. Benefit: enhanced tissue oxygenation for specified medical conditions. SIGMA 3400 includes provision for switching between oxygen and air pressurization.
Clinical Evidence
Bench testing only. Device relies on established safety standards for pressure vessels (ASME Boiler and Pressure Vessel Code Section VIII, Division 1; ASME PVHO-1). No clinical data presented.
Technological Characteristics
Class B monoplace hyperbaric system. Materials: ASME-certified metal components (ASME Section II) and acrylic plastic cylinder (ASME PVHO-1). Energy: fully pneumatic (no electrical/electronic components). Dimensions: 33.3" ID x 90" L acrylic cylinder. Connectivity: none. Sterilization: N/A (pressurized oxygen environment).
Indications for Use
Indicated for patients requiring hyperbaric oxygen therapy for: air/gas embolism, carbon monoxide/smoke inhalation, compromised skin grafts/flaps, crush injuries/acute traumatic ischemias, decompression sickness, problem wounds, exceptional blood loss (anemia), gas gangrene, intracranial abscess, necrotizing soft tissue infections, radiation tissue damage (osteoradionecrosis), refractory osteomyelitis, and thermal burns.
Regulatory Classification
Identification
A hyperbaric chamber is a device that is intended to increase the environmental oxygen pressure to promote the movement of oxygen from the environment to a patient's tissue by means of pressurization that is greater than atmospheric pressure. This device does not include topical oxygen chambers for extremities (§ 878.5650).
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for Perry Baromedical. The logo consists of a circular graphic on the left and the text "PERRY BAROMEDICAL" on the right. The graphic is a stylized representation of a circle with several smaller circles arranged around it. The text is in a bold, serif font, with "PERRY" on top of "BAROMEDICAL".
March 17, 1999
3660 Interstate Parkway Riviera Beach Florida 33404 USA 800-741-4376 561 =840=0395 FAX: 561.840.0398
K990927
11-12-99
510{k) SUMMARY Page 1 of 3
Food and Drug Administration Center for Devices and Radiological Health Document Mail Center (HFZ-401) 9200 Corporate Blvd. Rockville, Maryland 20850
Document Control Clerk Attention :
SIGMA 3400 Monoplace Hyperbaric Chamber Summary of Safety & Subject: Effectiveness Information :
Gentlemen:
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA of 1990 and 21 CFR 807.92.
Substantial Equivalence: The Perry Baromedical Corporation SIGMA 3400 Monoplace Hyperbaric Chamber is substantially equivalent to the Perry Baromedical Corporation SIGMA I Monoplace Hyperbaric Chamber, [510(k) K832127], and the Perry Baromedical Corporation SIGMA Plus Monoplace Hyperbaric Chamber, [510(k) 974863].
The SIGMA 3400 has the same intended use and the same technological characteristics as the SIGMA I and SIGMA Plus predicate devices. The scope and operation of the SIGMA 3400 is identical to that of the SIGMA I and SIGMA Plus in the following areas:
- The critical component of both systems consists of an ASME pressure vessel that is 1 designed, fabricated, and tested in accordance with the requirements of the ASME Boiler and Pressure Vessel Code, Section VIII, Division 1; and ASME PVHO-1, Safety Standard for Pressure Vessels for Human Occupancy.
- The pressure vessel consists of certified metal components constructed of materials in 2 conformance with the ASME Boiler and Pressure Vessel Code, Section II - Materials. In addition to the metal parts, the pressure retaining boundary consists of an acrylic plastic cylinder, designed and constructed to the requirements of ASME PVHO-1, Safety Standard for Pressure Vessels for Human Occupancy.
10
MULTIPLACE HYPERBARIC THERAPY SYSTEMS MONOPLACE . DUALPLACE
2)
{1}------------------------------------------------
- The pressure vessel is protected from accidental over pressurization by an ASME "UV" 3 stamped pressure relief valve.
- The medium used for pressurization of the chamber is medical grade oxygen. 4
- Treatment capacity of the chamber is one patient. 5
- Communication between the patient / attendants is through an intrinsically safe б communications system.
- The SIGMA I, SIGMA Plus and SIGMA 3400 chambers are used to provide 7 Hyperbaric Oxygen Therapy, prescribed by a licensed physician, where medical grade oxygen is administered to patients while under pressure, by the patient breathing oxygen from the chamber atmosphere that is pressurized with pure oxygen. The breathing of oxygen at elevated pressure promotes the movement of oxygen into the patient's tissues.
- The chamber pressurization and depressurization control system is completely 8 pneumatic, with no electrical or electronic components.
- Chambers are Class "B" monoplace hyperbaric systems. 9
Differences do exist between the SIGMA 3400 ,the SIGMA Plus and the SIGMA I chambers; they include:
- The PVHO-1 acrylic cylinder in the SIGMA 3400 chamber is 33.3" inside diameter and 1 90" long; the PVHO-1 acrylic cylinder in the SIGMA Plus chamber is 40" inside diameter by 65" long, and the PVHO-1 acrylic cylinder in the SIGMA I chamber is 25.25" inside diameter by 80" long.
- The acrylic cylinder of the SIGMA 3400 has been designed for a operational 2. temperature range of 32 degrees F to 100 degrees F. The SIGMA I and SIGMA Plus cylinders were designed for a 32 degree F to 125 degree F operating range. Based on the actual operating environment of a hospital, the higher 125 degree temperature limit would never be reached in normal operation, as the chamber rooms are required to be maintained at temperatures less than 75 degrees F for patient comfort.
- The pneumatic controls for the SIGMA 3400 chamber and the SIGMA I chamber are 3. mounted in a panel mounted on one side of the chamber. The pneumatic controls for the SIGMA Plus chamber are mounted in a control box that is suspended from a moveable arm.
{2}------------------------------------------------
- The SIGMA 3400 monoplace chamber has an aluminum chassis with integral side 4 covers; the SIGMA Plus Chamber has gelcoated fiberglass cosmetic covers on the sides and ends of the chamber; and the SIGMA I Hyperbaric Chamber has aluminum side cosmetic covers as part of the chassis.
- The SIGMA 3400 monopiace chamber has provision for changing from oxygen to air 5. pressurization during treatment, which allows the operator more control of the environment inside the chamber. The SIGMA Plus and SIGMA I chambers are oxygen only pressurization.
The changes to the SIGMA I and SIGMA Plus systems resulting in the SIGMA 3400 Hyperbaric Chamber enhance its ease of operation, and do not adversely effect the safety and effectiveness of the device. The basic treatment method is identical, only the chamber acrylic window diameter, length and operating temperature range has been changed
None of the above information is confidential and all may be made available to the public upon written request.
Perry Baromedical Corporation
James Dodson
James P. Dodson
Quality Assurance Manager
31/2-99
Date
ત્વ
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows a circular seal with text around the perimeter and a stylized eagle in the center. The text around the perimeter reads "HEALTH & HUMAN SERVICES - USA". The eagle in the center is depicted with three curved lines representing its wings and a wavy line representing its body.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Nov 1 2 1999
Mr. James P. Dodson Perry Baromedical Corp. 3660 Interstate Parkway Riviera Beach, FL 33404-3411
Re: K990927 SIGMA 3400 Monoplace Hyperbaric Chamber Regulatory Class: II (two) Product Code: 73 CBF August 27, 1999 Dated: Received: August 30, 1999
Dear Mr. Dodson:
We have reviewed your Section 510(k) notification of intent to market we nave referenced above and we have determined the device is the device referenced about a the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified Medical Device Amendales, is the Federal Food, Drug, and In accordance with the provibitions of therefore, market the device, subject to The general controls the general controls provisions of the Act. che general controlo proclude requirements for annual registration, provisions of the , good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special It your device is cremarket Approval), it may be subject to such controls) of Craoo Irs (isting major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 A substantially equivalent determination assumes compliance to 895. with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such Failure to comply with the GMP regulation may result in assumptions. regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any . obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{4}------------------------------------------------
## Page 2 - Mr. James P. Dodson
This letter will allow you to begin marketing your device as described This letter will allow you to begin marketing of substantial in your 510(k) premation to a legally marketed predicate device equivalence of your device co a regarly marked on thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling If you desire specific advice for your and additionally 809.10 for in vitro regulation (21 CFR Parl and and the Office of Compliance at diagnostic devices), prease contact the promotion and (301) 594-4648. Additionally, for questions on fire packson
advertising of your device, please contact the office of Compliance at
advertising of your devices nota the regula (301) 594-4639. Also, please note the regulation entitled, (301) 594-4639. Also, premarket notification"(21 CER 807.97).
"Misbranding by reference to premarket notifiitia under the Act may "Misbranding by reference on your responsibilities under the Act may Other general information of Small Manufacturers Assistance at its internet be obtained from the Division of Small Hands 6597, or at its internet
toll-free number (800) 638–2041 or (301) 443–6597, or at its internet toff-free "http://www.fda.gov/cdrh/dsma/dsmamain.html".
Sincerely yours,
for H. Winterkorn for,
celia M. Witten, Ph.D., M.D. Acting Director Division of Cardiovascular, Respiratory, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the logo for Perry Baromedical. The logo consists of a circular shape on the left side with several small circles inside and around it. To the right of the circular shape, the words "PERRY BAROMEDICAL" are written in a bold, sans-serif font, with "PERRY" on top of "BAROMEDICAL".
## 510(k) K 990927
## SIGMA 3400 Monoplace Hyperbaric Chamber
## INDICATIONS FOR USE
The SIGMA 3400 Monoplace Hyperbaric Chamber is indicated for use for the following clinical medical conditions in accordance with guidelines established by the Undersea and Hyperbaric Medical Society, as follows:
- Air or Gas Embolism 1.
- Carbon Monoxide / Smoke Inhalation 2.
- Compromised Skin Grafts and Flaps 3.
- Crush Injuries / Acute Traumatic Ischemias 4.
- Decompression Sickness ર
- Enhanced Healing in Selected Problem Wounds 6.
- Exceptional Blood Loss (Anemia) 7.
- Gas Gangrene (Clostridial Myonecrosis) 8.
- Intracranial Abscess 9.
- Necrotizing Soft Tissue Infections 10.
- Radiation Tissue Damage (Osteoradionecrosis) 11.
- Refractory Osteomyelitis 12.
- Thermal Burns 13.
Concurrence of CDRH, Office of Device Evaluation (ODE)
| Prescription Use<br>(Per 21 CFR 801.109) | <span style="text-decoration: overline;">✓</span> | OR | Over-The-Counter-Use<br>(Optional Format 1-2-96) | <span style="text-decoration: overline;"></span> |
|------------------------------------------|---------------------------------------------------|----|--------------------------------------------------|--------------------------------------------------|
|------------------------------------------|---------------------------------------------------|----|--------------------------------------------------|--------------------------------------------------|
Joan JA Wetherh
(Division Sign-Off)
Division of Cardiovascular, Respiratory,
and Neurological Devices
| 510(k) Number | <span style="text-decoration: overline;">K990927</span> |
|---------------|---------------------------------------------------------|
|---------------|---------------------------------------------------------|
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.