K984383 · Allergan, Inc. · LPN · Dec 18, 1998 · Ophthalmic
Device Facts
Record ID
K984383
Device Name
ULTRACARE NEUTRALIZING TABLETS
Applicant
Allergan, Inc.
Product Code
LPN · Ophthalmic
Decision Date
Dec 18, 1998
Decision
SESE
Submission Type
Special
Regulation
21 CFR 886.5928
Device Class
Class 2
Indications for Use
ULTRACARE Neutralizing Tablets are part of the ULTRACARE System, a disinfecting, neutralizing and storage system for daily and extended wear soft (hydrophilic) contact lenses in a chemical (not heat) lens care system. The ULTRACARE Neutralizing Tablets are indicated for use to neutralize the ULTRACARE Disinfecting Solution in the ULTRACARE System. ULTRACARE Neutralizing Tablets are added at the beginning of the disinfection cycle so that disinfection and neutralization occur without any additional steps.
Device Story
Tablet-based chemical neutralizing agent for soft contact lens care. Contains catalase, hydroxypropyl methylcellulose, and cyanocobalamin (Vitamin B12) color indicator. Used by patients at home as part of the ULTRACARE System. Tablet added to ULTRACARE Disinfecting Solution at start of disinfection cycle; enables simultaneous disinfection and neutralization. Eliminates need for additional steps. Benefits patient by simplifying lens maintenance regimen while ensuring effective neutralization of disinfecting solution.
Clinical Evidence
Three-month clinical study (n=59) evaluated safety and acceptability of ULTRACARE regimen. 96.7% (55/59) successful use rate. Primary endpoints: corneal staining and lens comfort; no apparent difference compared to predicate. Preclinical testing included 28-day subacute ocular safety study (no significant irritation/toxicity) and microbiological testing confirming 'stand-alone' disinfection efficacy.
Technological Characteristics
Smooth, round, beige to pale pink tablets. Composition: catalase, hydroxypropyl methylcellulose, cyanocobalamin (color indicator), buffering and tableting agents. Chemical neutralization principle. Standalone use within a lens care regimen. No electronic or software components.
Indications for Use
Indicated for users of daily and extended wear soft (hydrophilic) contact lenses requiring chemical disinfection, neutralization, and storage.
Regulatory Classification
Identification
A soft (hydrophilic) contact lens care product is a device intended for use in the cleaning, rinsing, disinfecting, lubricating/rewetting, or storing of a soft (hydrophilic) contact lens. This includes all solutions and tablets used together with soft (hydrophilic) contact lenses and heat disinfecting units intended to disinfect a soft (hydrophilic) contact lens by means of heat.
Special Controls
*Classification.* Class II (Special Controls) Guidance Document: “Guidance for Industry Premarket Notification (510(k)) Guidance Document for Contact Lens Care Products.”
Predicate Devices
ULTRACARE® Neutralizing Tablet with Color Indicator (PMA P850088/S36)
Reference Devices
ULTRAZYME® Enzymatic Cleaner
Submission Summary (Full Text)
{0}------------------------------------------------
2525 Dupont Drive, P.O. Box 19534, Irvine, California, USA 92623-9534 Telephone: (714) 246-4500 Website: www.allergan.com
Image /page/0/Picture/3 description: The image shows a black and white abstract design. The design consists of several horizontal lines of varying lengths, stacked vertically. The lines are thicker in the middle and taper towards the ends, creating a rounded, capsule-like shape for each line. The overall arrangement of the lines forms a symmetrical, somewhat oval or diamond-like pattern.
# K 98 4383
December 4. 1998
## 510(k) SUMMARY
#### Submitter Information 1.
Allergan 2525 Dupont Drive Irvine, California 92612
| Contact Person: | Paul J. Nowacki |
|-----------------|-----------------------------|
| | Manager, Regulatory Affairs |
Telephone Number: (714) 246-6761
#### Device Name 2.
| Classification Name: | Soft (hydrophilic) contact lens care products |
|----------------------|-----------------------------------------------|
| Proprietary Name | ULTRACARE® Neutralizing Tablets |
#### Predicate Device 3.
The predicate device is ULTRACARE® Neutralizing Tablet with Color Indicator.
#### Description of the Device 4.
ULTRACARE Neutralizing Tablets are smooth, round, beige to pale pink tablets that contain catalase, hydroxypropyl methylcellulose, and cyanocobalamin (Vitamin B12) as a color indicator, with buffering and tableting agents.
#### ਨੰ Indications for Use
ULTRACARE Neutralizing Tablets are part of the ULTRACARE® System, a disinfecting, neutralizing and storage system for daily and extended wear soft (hydrophilic) contact lenses in a chemical (not heat) lens care system.
The ULTRACARE Neutralizing Tablets are indicated for use to neutralize the ULTRACARE® Disinfecting Solution in the ULTRACARE System. ULTRACARE Neutralizing Tablets are added at the beginning of the disinfection cycle so that disinfection and neutralization occur without any additional steps.
{1}------------------------------------------------
#### Description of Safety and Substantial Equivalence 6.
A series of preclinical tests and clinical testing was performed to demonstrate the safety and effectiveness of ULTRACARE® Neutralizing Tablets. The tests were designed and performed in accordance with the guidelines set forth in FDA's May 1, 1997 Guidance for Industry - Premarket Notification [510(k)] Guidance Document for Contact Lens Care Products. The following is a summary of the test results.
### Preclinical Testing
A series of in-vitro and in-vivo preclinical chemical, microbiological and toxicological studies were performed to assess the safety and effectiveness of ULTRACARE Neutralizing Tablets. The results of these studies indicate that ULTRACARE Neutralizing Tablets are substantially equivalent to the predicate device.
### Lens compatibility
A study was conducted to determine the compatibility of hydrogel contact lenses with the ULTRACARE® lens care regimen consisting of ULTRACARE® Disinfecting Solution, ULTRACARE® Neutralizing Tablets and ULTRAZYME® Enzymatic Cleaner. A control regimen using the predicate device was also tested.
Representative lenses from FDA Lens Groups 1 and 4 were monitored for changes in power, diameter, basecurve, spectral transmittance and material surface changes during and after 30 regimen cycles.
The results indicated that ULTRACARE Neutralizing Tablets used in combination with ULTRACARE Disinfecting Solution and ULTRAZYME Enzymatic Cleaner are compatible with hydrogel contact lenses and perform comparably to the predicate device.
### Microbiology
The antimicrobial efficacy of the ULTRACARE® System using ULTRACARE Neutralizing Tablets was evaluated, in the presence and absence of ULTRAZYME Enzymatic Cleaner, against FDA's recommended panel of microorganisms.
The test results showed that the disinfection system using ULTRACARE Neutralizing Tablets met the criteria for "stand-alone" contact lens disinfecting products.
{2}------------------------------------------------
### Toxicology
A 28-day subacute ocular safety study was performed using ULTRACARE® Neutralizing Tablets in conjunction with ULTRACARE® Disinfecting Solution and ULTRAZYME® Enzymatic Cleaner. The results of this study showed no clinically significant ocular discomfort, irritation or toxicity.
### Clinical Testing
A three-month clinical study was conducted to evaluate the safety and acceptability of ULTRACARE Neutralizing Tablets when used with ULTRACARE Disinfecting Solution for hydrogel contact lenses.. The results of the study showed that the ULTRACARE lens care regimen is safe and acceptable for its intended use based on:
- Successful use by 96.7% (55/59) of evaluable subjects .
- No apparent difference in the key safety variable of corneal staining compared . to the predicate device
- No apparent difference in the key acceptability variable of lens comfort . compared to the predicate device.
Results of the clinical study demonstrate the safety, acceptability and substantial equivalence of ULTRACARE Neutralizing Tablets to the predicate device for its intended use.
#### 7. Substantial Equivalence
ULTRACARE Neutralizing Tablets are substantially equivalent in terms of actions, indications for use, safety, and effectiveness to the predicate device: ULTRACARE Neutralizing Tablets with Color Indicator (approved for marketing under PMA P850088/S36).
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the seal of the Department of Health & Human Services-USA. The seal features a stylized image of an eagle with three lines representing its wings. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES-USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC 1 8 1998
Mr. Paul J. Nowacki Manager, Regulatory Affairs Allergan 2525 Dupont Drive P.O. Box 19534 Irvine, CA 92623-9534
Re: K984383 Trade Name: ULTRACARE ® Neutralizing Tablets with Color Indicator Regulatory Class: II Product Code: 86 LPN Dated: December 4, 1998 Received: December 8, 1998
Dear Mr. Nowacki:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations .
{4}------------------------------------------------
### Page 2 - Mr. Paul J. Nowacki
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on.the.promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
A Roerl rosenthal
A. Ralph Rosenthal, M.D. Director Division of Ophthalmic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Attachment 2
# Indications for Use Statement
・
:
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
| 510(k)<br>Number<br>(if known) | The predicate device, ULTRACARE® Neutralizing Tablets with<br>Color Indicator, was approved under PMA P850088/S36. |
|--------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device Name | ULTRACARE® Neutralizing Tablets |
| Indications<br>For Use | ULTRACARE Neutralizing Tablets are part of the ULTRACARE<br>System, a disinfecting, neutralizing and storage system for daily and<br>extended wear soft (hydrophilic) contact lenses in a chemical (not<br>heat) lens care system.<br><br>The ULTRACARE Neutralizing Tablets are indicated for use to<br>neutralize the ULTRACARE Disinfecting Solution in the<br>ULTRACARE System. ULTRACARE Neutralizing Tablets are added<br>at the beginning of the disinfection cycle so that disinfection and<br>neutralization occur without any additional steps. |
### PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED
Concurrence of CDRH, Office of Device Evaluation (ODE)
| (Division Sign-Off) | |
|--------------------------------|---------|
| Division of Ophthalmic Devices | |
| 510(k) Number | K984383 |
Prescription Use ____ (Per 21 CFR 801.109) OR Over-The-Counter Use X
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.