← Product Code [JFJ](/productcode/JFJ) · K984184

# WAKO L-TYPE AMYLASE (K984184)

_Wako Chemicals USA, Inc. · JFJ · Jan 13, 1999 · Clinical Chemistry · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K984184

## Device Facts

- **Applicant:** Wako Chemicals USA, Inc.
- **Product Code:** [JFJ](/productcode/JFJ.md)
- **Decision Date:** Jan 13, 1999
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 862.1070
- **Device Class:** Class 2
- **Review Panel:** Clinical Chemistry

## Indications for Use

The Wako L-type Amylase test is an in vitro diagnostic assay for the quantitative determination of amylase activity in serum.

## Device Story

Wako L-type Amylase is an in vitro diagnostic kinetic assay for serum amylase activity. Input: serum sample. Principle: sample reacts with defined-substrate p-nitrophenyl-a-maltopentaoside (BG5P); glucoamylase and a-glucosidase act as coupling enzymes to hydrolyze produced PNP-G2 into p-nitrophenol. Output: increase in absorbance measured at 405 nm, proportional to amylase activity. Used in clinical laboratory settings by trained personnel. Results assist physicians in diagnosing pancreatic and nonpancreatic disorders. Benefits include accurate, linear quantification of enzyme activity for clinical decision-making.

## Clinical Evidence

Bench testing only. Precision studies performed to evaluate day-to-day reproducibility. Linearity established up to 3000 IU/L. Minimum detectable level estimated at 1.0 IU/L.

## Technological Characteristics

Kinetic enzymatic assay using p-nitrophenyl-a-maltopentaoside (BG5P) substrate, glucoamylase, and a-glucosidase. Measures absorbance at 405 nm. Quantitative, in vitro diagnostic reagent system.

## Regulatory Identification

An amylase test system is a device intended to measure the activity of the enzyme amylase in serum and urine. Amylase measurements are used primarily for the diagnosis and treatment of pancreatitis (inflammation of the pancreas).

## Predicate Devices

- Sigma Amylase test

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

1984184

JAN 1 3 1999

Wako Chemicals USA, Inc. 1600 Beltwood Road, Richmond, VA 23237 U.S.A.

## 510(k) Summary of Safety and Effectiveness

The Wako L-type Amylase test is an in vitro diagnostic assay for the quantitative determination of amylase activity in serum.

Amylase is one of the digesting enzymes secreted predominantly from pancreas and salivary gland, which hydrolyzes a- 1,4-bonds of both straight-chain polysaccharides such as amylose and branched polysaccharides such as amylopectin. Determination of aamylase activity is largely of use in the diagnosis of pancreatic diseases, but is also of value in detecting nonpancreatic disorders such as renal insufficiency, salivary gland lesions, macroamylasemia, and intra-abdominal diseases. There are several methods used for the determination of a-amylase activity such as amyloclastic, saccharogenic, and defined-substrate methods.2 The Wako L-type Amylase is a kinetic assay employing a defined-substrate, p-nitrophenzy-a-maltopentaoside (BG5P), with glucoamylase and a-glucosidase as coupling enzymes.

When a sample is allowed to react with the BG5P, BG3 and p-nitrophenyl-a-maltoside (PNP-G2) are formed by the action of a-amylase in the sample. The PNP-G2 produced is hydrolyzed to p-nitrophenol by the reactions of glucoamylase and a-glucosidase. By measuring the increase in absorbance of p-nirophenol at the optimum wavelength of 405 nm, a - amylase activity in the sample is determined. A benzyl group in the nonreducing end glucose residue of GBSP prevents the hydrolysis by the cooupling enzymes and, thus, keeps a low blank absorbance. In this method, one unit of BG5P hydrolyzed by aamylase converts to one p-nitrophenol molecule. Therefore, one unit of a-amylase can be defined stoichiometrically as the amount of enzyme that produces one micro mol of p nitrophenol per minute.3,4

The safety and effectiveness of the Wako L-type Amylase assay is demonstrated by its substantial equivalency to the Sigma Amylse test.

Precision studies indicate acceptable values can be obtained on a day to day basis. The minimum detectable level of this method is estimated to be 1.0 IU/L. The Wako L-type Amylase assay had determined to be linear to 3000 IU/L.

{1}------------------------------------------------

510(k) Summary Wako L-type Amylase Page 2

References:

(

- Berk, J.E. and Fridhandler, L.: Ann. Intern. Med., 26, 235-264 (1980). 1.
- Burtis, C.A. and Ashwood, E.R .: Tietz Textbook of Clinical Chemistry, 20d ed., 2. Saunders, Philadelphia, 1994.
- Satomura, S., Sakata, Y., Omichi, K. and Ikenaka, T.: Clin. Chem. Acta, 174, 315-3. 324 (1988).
- Satomura, S., Iwata, T., Sakata, Y., Omichi, K. and Ikenaka, T .: Carbohydr. Res., 4. 176, 107-115 (1988).

Kim Hallum

Tonya Mallory, Senior Manager, Diagnostics January 12, 1999 Wako Chemicals USA, Inc. 1600 Bellwood Road Richmond, VA 23237

{2}------------------------------------------------

Public Health Service

Image /page/2/Picture/2 description: The image shows a partial view of a logo or emblem, specifically the symbol associated with the U.S. Department of Health and Human Services (HHS). The symbol features a stylized representation of a human figure in profile, with three overlapping bodies or figures suggesting community and support. The image is cropped, showing only the right side of the emblem and the text is not visible.

JAN 1 3 1999

Food and Drug Administration 2098 Gaither Road Rockville MD 20850

Ms. Tonya Mallory Senior Manager, Diagnostics Wako Chemicals USA, Inc. 1600 Bellwood Road Richmond, Virginia 23237

Re: K984184 Trade Name: Wako L-type Amylase Regulatory Class: II Product Code: JFJ Dated: November 16, 1998 Received: November 23, 1998

Dear Ms. Mallory:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

{3}------------------------------------------------

## Page 2

Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88), this device may require a CLIA complexity categorization. To determine if it does, you should contact the Centers for Disease Control and Prevention (CDC) at (770) 488-7655.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".

Sincerely yours,

Steven Autman

Steven I. Gutman, M.D, M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

Page of

K9 841 84 NUMBER (IF KNOWN) : 510 (k) DEVICE NAME: INDICATIONS FOR USE:

fine activit ull suremen nota an ari used pan creat DF

Jean Cooper
(Division Sign-Off)
Division of Clinical Laboratory Devices

510(k) Number

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription Use (Per 21 CFR 801.109)

OR

Over-The-Counter-Use (Optional Format 1-2-96)

---

**Source:** [https://fda-staging.innolitics.com/device/K984184](https://fda-staging.innolitics.com/device/K984184)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
