← Product Code [EHD](/productcode/EHD) · K984030

# VIPERSOFT (K984030)

_Integra Medical · EHD · Feb 10, 1999 · Dental · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K984030

## Device Facts

- **Applicant:** Integra Medical
- **Product Code:** [EHD](/productcode/EHD.md)
- **Decision Date:** Feb 10, 1999
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 872.1800
- **Device Class:** Class 2
- **Review Panel:** Dental
- **Attributes:** Software as a Medical Device

## Indications for Use

The software, Vipersoft, for extraoral X-ray units is used to process digital images from extraoral X-ray units in order to enable a dentist to diagnose the dental state of the teeth of a patient.

## Device Story

Vipersoft is a software application designed for use with extraoral X-ray units. It processes digital X-ray images to facilitate dental diagnosis. The software is intended for use by dentists in a clinical setting. By processing and displaying digital images, the device assists the clinician in evaluating the dental state of a patient's teeth, supporting clinical decision-making regarding dental health.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

Software application for processing digital images from extraoral X-ray units. Operates as a digital image processing tool for dental diagnostic support.

## Regulatory Identification

An extraoral source x-ray system is an AC-powered device that produces x-rays and is intended for dental radiographic examination and diagnosis of diseases of the teeth, jaw, and oral structures. The x-ray source (a tube) is located outside the mouth. This generic type of device may include patient and equipment supports and component parts.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

## DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized image of an eagle with three lines forming its body and wings. The eagle is facing to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

FEB 1 0 1999

Integra Medical W. Edward Johansen C/o W. Edward Johansen, Atty. 11661 San Vicente Blvd. Los Angeles, CA 90049

Re:

K984030 Vipersoft™ (Software for Extraoral X-ray Units Dated: November 10, 1998 Received: November 12, 1998 Regulatory class: II 21 CFR 892.1800/Procode: 90 EHD Regulatory class: I 21 CFR 892.2010/Procode: 90 LMB 21 CFR 892.2020/Procode: 90 LMD

Dear Mr. Johansen:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, isting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register . Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in yitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".

Sincerely yours,

.

Capt. Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

{1}------------------------------------------------

## PREMARKET NOTIFICATION

## INDICATIONS FOR USE

510(k) Number:

Device Name:__Software for extraoral X-ray units

Indications for Use:

The software, Vipersoft, for extraoral X-ray units is used to process digital images from extraoral X-ray units in order to enable a dentist to diagnose the dental state of the teeth of a patient.

Concurrence of CDRH, Office of Device Evaluation (ODE)

David A. Ingram

---

(Division Sign-Off)

Division of Reproductive, Abdominal, ENI, and Radiological De 510(k) Number

Prescription Use: √ OR

Over-The-Counter-Use :_

(Per 21 CFR 801.109

---

**Source:** [https://fda-staging.innolitics.com/device/K984030](https://fda-staging.innolitics.com/device/K984030)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).