← Product Code [LNH](/productcode/LNH) · K983902

# FIELD EFFECTS MRI SYSTEM (K983902)

_Intermagnetics General Corp. · LNH · Jan 7, 1999 · Radiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K983902

## Device Facts

- **Applicant:** Intermagnetics General Corp.
- **Product Code:** [LNH](/productcode/LNH.md)
- **Decision Date:** Jan 7, 1999
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 892.1000
- **Device Class:** Class 2
- **Review Panel:** Radiology

## Indications for Use

The Field Effects MRI system produces cross-sectional images: • Anatomical Region: General body anatomy, including head, spine, torso, and extremities • 1H nuclei (Proton) . Nucleus excited: • Diagnostic uses: Images correspond to the distribution of 1H nuclei exhibiting nuclear magnetic resonance, with image intensity dependent upon NMR parameters, including spin-lattice relaxation time (T1) spin-spin relaxation time (T2) density of nuclei (p) flow velocity chemical shift (δ) • Clinical use: lmages may be interpreted by a trained physician to yield information that can be useful in the determination of a diagnosis

## Device Story

Field Effects MRI is a 0.15T elliptical magnetic resonance diagnostic device. It acquires 1H proton signals using various RF coils (head, spine, abdomen, knee) and pulse sequences (Spin Echo, Gradient Echo, Fast Spin Echo, Inversion Recovery). The system transforms these signals into cross-sectional images based on NMR parameters (T1, T2, proton density, flow, chemical shift). Used in stationary clinical settings, the device is operated by trained personnel. Physicians interpret the resulting images to assist in clinical diagnosis. The device is an enhancement of the previously cleared IMiG-MRI (K963953) and TREX MRI (K982157) systems, incorporating updated image processing software to improve clinical utility.

## Clinical Evidence

No clinical data provided. Substantial equivalence is based on bench testing and comparison to predicate devices.

## Technological Characteristics

0.15 Tesla static magnetic field; 18.4 Tesla/sec max rate of change; 0.05W/kg RF power deposition. Elliptical form factor. Employs quadrature and linear RF coils. Supports Spin Echo, Gradient Echo, Fast Spin Echo, and Inversion Recovery acquisition sequences. Software-based image processing enhancement.

## Regulatory Identification

A magnetic resonance diagnostic device is intended for general diagnostic use to present images which reflect the spatial distribution and/or magnetic resonance spectra which reflect frequency and distribution of nuclei exhibiting nuclear magnetic resonance. Other physical parameters derived from the images and/or spectra may also be produced. The device includes hydrogen-1 (proton) imaging, sodium-23 imaging, hydrogen-1 spectroscopy, phosphorus-31 spectroscopy, and chemical shift imaging (preserving simultaneous frequency and spatial information).

## Special Controls

*Classification.* Class II (special controls). A magnetic resonance imaging disposable kit intended for use with a magnetic resonance diagnostic device only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

## Predicate Devices

- IMiG-MRI ([K963953](/device/K963953.md))
- Hitachi MRP-5000 with Version 5.0 Operating System Software ([K943799](/device/K943799.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K983902

JAN 7 1999

:

# Attachment 1 510(k) Summary of Safety and Effectiveness

{1}------------------------------------------------

#### 1.0 SUBMITTER INFORMATION:

- Field Effects, a division of Intermagnetics General Corporation 1.1 Submitter: 300 Vesper Executive Park Tynasborough, MA 01879 PH: 978 649-8590 FX: 978 649-8520 Email: GHURST@IGC.com
- Grea Hurst, Ph.D. 1.2 Contact: Mar., Imaging Science and Applications
- 1.3 Date: October 30, 1998
- 1.4 Regulatory Counsel: Jonathan S. Kahan, Attorney at Law Hoaan & Hartson 555 Thirteenth St. NW Washington, DC 20004-1109 PH: 202 637-5794 FX: 202 637-5910

#### 2.0 DEVICE NAME:

- 2.1 Classification Panel: Radiology
- 892. 1000 Maanetic Resonance Diagnostic Device 2.2 Classification Number:
- 2.3 Product Nomenclature: System, Nuclear Magnetic Resonance Imaging
- 2.4 Product Code(s): 90LNH
- 2.5 Trade/Proprietary Name: Field Effects MRI
- 2.6 Predicate Device(s): IMiG-MRI, K963953 Hitachi MRP-5000 with Version 5.0 Operating System Software, K943799

#### 3.0 DEVICE DESCRIPTION:

#### 3.1 FUNCTION

Identical to the IMiG-MRI 510(k) K963953. The original IMiG-MRI system was renamed as TREX MRI in 510(k) submission K982157. As a result of changing business arrangements, the TREX MRI is now renamed as the Field Effects MRI System. In addition, following successful FDA determination of substantial equivalence of this 510(k) submission for the Image Processing software, Field Effects will cease commercialization efforts and support for the Field Effects MRI System. Service Support will be available through SMIS (refer to ttem 9, Address of Manufacturing Facilities for SMIS contact information). With the exception of the device modifications identified in this 510(k) submission, and the renaming of the product, the Field Effects MRI System is identical to the original IMiG-MRI system (and to the TREX.MRI).

The Field Effects MRI 0.15T Elliptical MRI Magnetic Resonance Diagnostic Device is being enhanced by image processing software to increase the clinical utility of the Field Effects MRI System in the stationary configuration.

{2}------------------------------------------------

#### 3.2 Safety Parameter Summary

| Maximum static magnetic field            | 0.15 Tesla                      |
|------------------------------------------|---------------------------------|
| Maximum rate of magnetic field<br>change | 18.4 Tesla/sec                  |
| Maximum RF power deposition              | 0.05W/kg                        |
| Acoustic noise levels                    | 114dB peak; 95dB A-weighted RMS |

#### Performance Parameter Summary 3.3

ldentical to the Predicate Device.

#### 3.4 General Safety and Effectiveness Summary

Safe and effective use of the machine is assured by the associated labeling. This labeling includes: advertising brochures, Site Planning Guide, and Instructions for Use (comprised of Clinical Users Guide, User Safety Guide, User Training Guide, User Applications Guide, and User QA & Maintenance Guide).

#### DEVICE INTENDED USE: 4.0

The Field Effects MRI system produces cross-sectional images:

- · Anatomical Region: General body anatomy, including head, spine, torso, and extremities
- 1H nuclei (Proton) . Nucleus excited:
- Diagnostic uses: Images correspond to the distribution of 1H nuclei exhibiting nuclear magnetic resonance, with image intensity dependent upon NMR parameters, including spin-lattice relaxation time (T1) spin-spin relaxation time (T2) density of nuclei (p) flow velocity chemical shift (δ)
- · Clinical use: lmages may be interpreted by a trained physician to yield information that can be useful in the determination of a diagnosis

#### 5.0 DEVICE TECHNOLOGICAL CHARACTERISTICS:

Identical to the Predicate Device.

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image is a black and white logo for the Department of Health & Human Services - USA. The logo is circular in shape, with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter of the circle. In the center of the circle is an image of an eagle with its wings spread.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

10000 7 JAN

Ian L. Pykett, Ph.D., F.Inst.P. Vice President. Technology Development Intermagnetics General Corporation 450 Old Niskavuna Road P.O. Box 461 Latham, NY 12110-0461

Re:

K983902

Field Effects MRI Magnetic Resonance Diagnostic Device Dated: October 30, 1998 Received: November 3, 1998 Regulatory class: II 21 CFR 892.1000/Procode: 90 LNH

Dear Dr. Pykett:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Fallure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".

Sincerely yours,

Capt. Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

## 510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________

Device Name: Image Processing Software for Field Effects MRI

Indications for Use:

The Field Effects MRI system produces cross-sectional images:

| • | Anatomical Region: | General body anatomy, including head, spine, torso, and extremities                                                                                                                                                                                                                                      |
|---|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| • | Nucleus excited:   | 1H nuclei (Proton)                                                                                                                                                                                                                                                                                       |
| • | Diagnostic uses:   | Images correspond to the distribution of 1H nuclei exhibiting nuclear magnetic resonance, with image intensity dependent upon NMR parameters, including<br>- spin-lattice relaxation time (T1)<br>- spin-spin relaxation time (T2)<br>- density of nuclei (ρ)<br>- flow velocity<br>- chemical shift (δ) |
| • | Clinical use:      | Images may be interpreted by a trained physician to yield information that can be useful in the determination of a diagnosis.                                                                                                                                                                            |
| • | RF Coils:          | Head - quadrature<br>Cervical Spine - quadrature<br>Lumbar Spine, Thoracic Spine, and Abdomen - quadrature<br>Knee - linear                                                                                                                                                                              |
| • | Image Acquisition  | Spin Echo<br>Gradient Echo (GE,RGE)<br>Fast Spin Echo (FSE)<br>Fast Dual Echo (FDE)<br>3D Fast Gradient Echo (3DGE, 3DRGE)<br>Inversion Recovery with Fast Spin Echo (FSE STIR, FSE FLAIR)                                                                                                               |

### (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

| Concurrence of CDRH, Office of Device Evaluation (ODE) |                                                               |                     |  |
|--------------------------------------------------------|---------------------------------------------------------------|---------------------|--|
|                                                        | <table><tr><td>(Division Sign-Off)</td><td></td></tr></table> | (Division Sign-Off) |  |
| (Division Sign-Off)                                    |                                                               |                     |  |

| Prescription Use (Per 21 CFR 801-109 | ✓ |
|--------------------------------------|---|
|--------------------------------------|---|

|               | Division of Reproductive, Abdominal, ENT Over-The-Counter Use ______ |
|---------------|----------------------------------------------------------------------|
|               | and Radiological Devices                                             |
| 510(k) Number | K983902                                                              |

|  | (Optional Format 1-2-96) |
|--|--------------------------|
|--|--------------------------|

---

**Source:** [https://fda-staging.innolitics.com/device/K983902](https://fda-staging.innolitics.com/device/K983902)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).