ADVANCED AUTOMATIC DETECTOR SELECTION OPTION FOR GLORY

K983313 · Elscint, Inc. · IZH · Dec 11, 1998 · Radiology

Device Facts

Record IDK983313
Device NameADVANCED AUTOMATIC DETECTOR SELECTION OPTION FOR GLORY
ApplicantElscint, Inc.
Product CodeIZH · Radiology
Decision DateDec 11, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1710
Device ClassClass 2

Indications for Use

Radiography of the breast Preoperative wire localization and stereotactic biopsy procedures

Device Story

Advanced Automatic Detector Selection (AADS) is an optional feature for the GLORY mammography system. It enhances the automatic exposure control (AEC) by identifying the densest breast tissue region to determine optimal exposure parameters. The system uses radiation sensors to detect tissue density; the algorithm selects the appropriate detector location to ensure accurate exposure. This process occurs during standard mammographic imaging in clinical settings, operated by radiology technicians. The output is an optimized X-ray exposure, which improves image quality for diagnostic and screening purposes, aiding clinicians in breast cancer detection and localization.

Clinical Evidence

No clinical data provided. Safety and effectiveness are supported by adherence to international standards (IEC 601-1, 601-2), hazard analysis, and system verification and validation processes.

Technological Characteristics

Mammographic X-ray system component. Features automatic exposure control (AEC) with detector selection logic. Complies with IEC 601-1 (electrical) and 601-2 (mechanical) standards. Software-based control for exposure parameter determination.

Indications for Use

Indicated for screening and diagnostic breast radiography, including preoperative wire localization and stereotactic biopsy procedures.

Regulatory Classification

Identification

A mammographic x-ray system is a device intended to be used to produce radiographs of the breast. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ DEC 1 1 1998 Elscint, Inc. Corporate Headquarters 22 Paris Avenue Rockleigh, NJ 07647 Tel. 201 750-3240 1-800-ELSCINT Fax 201 750-3232 Elscint Web Site: http://www.elscint.co.il 983313 # 510(k) Summary This 510(k) Summary provides the information required by 21 CFR 807.87(h). #### Submitter's Name and Address: 1. Elscint Inc., 22 Paris Avenue, Rockleigh, NJ 07647 ### Contact Person and Telephone No .: Steven M. Kay, Director, Regulatory Affairs and Quality Assurance, (201) 750-3240. #### Date of Summary: 17 September 1998 ### 2. Product Identification Trade/Proprietary Name: Advanced Automatic Detector Selection (AADS) option for the GLORY Common Name: Option Classification Name: Mammographic X-Ray System (21 CFR 892.1710/Procode: 90 IZH) ### 3. Predicate Device(s): GLORY (K970680) mammography system #### 4. Device Description: The Advanced Automatic Detector Selection (AADS) option is used with the automatic exposure control of the GLORY mammography system. With the AADS option, the legally marketed GLORY system can determine exposure parameters automatically from a detector located beneath the densest breast tissue. #### 5. Intended Use: The intended use and the indications for use of the GLORY mammography system (Screening and diagnostic breast radiography) are unchanged. #### 6. Safety and Effectiveness: The GLORY is designed to comply with IEC Electrical (601-1) and Mechanical (601-2) international standards. Potential electrical, mechanical, radiation and software hazards are identified through hazard analysis. Product safety and quality are maintained by: - Adherence to Federal and International standards . - System verification and validation, continuing review of user requirements and the . implementation of a Quality System that conforms to Federal OSR and ISO requirements. To the best of our judgement, the ADDS option does not result in any new potential safety risks and does not significantly change the effectiveness of the GLORY system. ## 7. Equivalency Information Summary: It is the opinion of Elscint, Inc. that the ADDS option is of a comparable type and substantially equivalent to the currently marketed GLORY mammography system. {1}------------------------------------------------ Image /page/1/Picture/0 description: The image shows the logo for the Department of Health & Human Services USA. The logo consists of a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the circumference. Inside the circle is a stylized image of an eagle with its wings spread. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 DEC 1 1 1998 Steven M. Kay Director of Regulatory Affairs Elscint, Inc. 22 Paris Avenue Rockleigh, NJ 07647 Re: K983313 > Advanced Automatic Detector Selection Option for Glory Mammography System (ADDS Option) Dated: September 18, 1998 Received: September 21, 1998 21 CFR 892.1710/Procode: 90 IZH Dear Mr. Kay: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for intro disgnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compirance at (301) 594-4639. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrivdsmardsmamain.html". Sincerely yours, Lillian Yin, Ph.D. Lillian Yin, Ph.D. Director, Division of Reproductive Abdominal, Ear, Nose and Throa and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ 510(k) Number (if known): # Device Name: Advanced Automatic Detector Selection Option for GLORY Mammography System Indications For Use: Radiography of the breast Preoperative wire localization and stereotactic biopsy procedures (Please do not write below this line-continue on another page if needed) (Concurrence of CDRH, Office of Device Evaluation(ODE) ![Signature](signature.png) (Division Sign-Off) Division of Reproductive, Abdominal, ENT, and Radiological Devices | 510(k) Number | K983313 | |---------------|---------| |---------------|---------| | Prescription Use | <img alt="Check" src="check.png"/> | OR | Over-The-Counter Use | |----------------------|------------------------------------|----|----------------------| | (Per 21 CFR 801.109) | | | |
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...