← Product Code [GEX](/productcode/GEX) · K981952

# COMBINATION ND:YAG AND FREQUENCY DOUBLED SOLID STATE GREEN LASER (K981952)

_Instruments For Medicine and Diagnostics · GEX · Sep 1, 1998 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K981952

## Device Facts

- **Applicant:** Instruments For Medicine and Diagnostics
- **Product Code:** [GEX](/productcode/GEX.md)
- **Decision Date:** Sep 1, 1998
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4810
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

532nm Wavelength: General Surgery: Coagulation, hemostasis, vaporization, excision, and incision of tissue. Photocoagulation of Vessels/Veins up to 1.5 mm Endoscopic & Laparoscopic: Excising, Coagulation or Vaporization of tissue during Endoscopic or Laparoscopic procedures, Cholecystectomy and Appendectomy. Gynecology: Ablation or lysis of intra-abdominal tissues via laparotomy or laparoscope. Ablation of endometrial implants, lysis of adhesions, ablation of the uterosacral ligaments, cutting/coagulating, treatment of uterine polyps and fibroids, salpingo-ophorolysis, and transection of uterine septa. Laryngology: Photocoagulation or Vaporization of soft or fibrous tissue such as; hereditary hemorrhagic telangiectasia (vascular lesions), pigmented structures that are highly vascular, and tonsillectomy. Otology: For; stapedotomy, stapedectomy, tympanoplasty with fascia graft, myringotomies, control of bleeding, removal of osseous disease of the external canal, removal of acoustic neuromas, lysis of adhesions and soft tissue adhesion, in both micro- and macro- otologic procedures. Rhinology: For; control of epistaxis, turbinate reduction (excludes bone), treatment of endonasal polyps, hereditary hemorrhagic telangiectasia, synechia, hemangiomas, telangiectasia, vaporize of maxillary sinus cysts and polyps, treatment of papillomas and granulomas, endonasal dacryocystorhinostomy, treatment of lesions within the nose and sinus, creation of nasoantral window and coagulation of vessels or veins up to 1.5 mm in diameter. Urology: Coagulation of veins or vessels up to 1.5 mm in diameter, management of condyloma acuminata, carcinoma in situ, small papillary bladder tumors, port wine stains, hemangioma of the external genitalia or bladder and urethral recanalization. Neurosurgery: For; dorsal root entry zone lesions, spinal intramedullary tumor, medulloblastomas, acoustic neuromas, intracranial meningiomas, ventricular ependymomas, choroid plexus, carcinomas, hemangioblastomas, ependymoma extending into the brain stem, and intra- / extra- axial spinal cord tumors. Ophthalmology: For; posterior and anterior treatment procedures including; diabetic retinopathy, retinal detachments, ablate tissues of the iris or trabeculum, peripheral iridectomy and iridotomy, trabeculoplasty, and senile macular degeneration. Other conditions of the retina in which the laser is deemed useful involving endophotocoagulation. Extraorbital procedures such as; coagulation of vessels or veins up to 1.5 mm in diameter, extra orbital pigmented or venous lesions; port wine hemangiomas or telangiectasia. Treatment for chronic dacryocystitis. Dermatology: For; treating vascular lesions, dermatologic lesions, and/or cutaneous lesions such as; facial or extremities telangiectasias, venous anomalies, leg veins up to 1.5 mm in diameter, and port wine stains. 1064nm Wavelength: General Surgery: For; incision or excision of all soft body tissues including; skin, subcutaneous and breast tissue, striated and smooth muscle, tendon and fascia, cartilage, mucous membrane, lymphatic tissue, internal organs and glands of the gastrointestinal, genitourinary, pulmonary, endocrine and exocrine systems, as well as cancers of theses systems. Treatment of larger and deeper vessels/veins up to 3.0 mm in diameter, 4.0 to 7.0 mm in depth. ENT, Head & Neck: For; incision or excision of all soft body tissues including; skin, subcutaneous tissue, striated and smooth muscle, tendon and fascia, cartilage, mucous membrane, lymphatic tissue, organs and glands of the ENT system and access via endoscope, microscope or direct visualization. Gastroenterology: For; esophageal neoplastic obstructions such as; squamous cell carcinoma, and adenocarcinoma, upper and lower GI bleeding such as; varices, esophagitis, esophageal ulcer, Mallory-Weiss tear, gastric ulcer, stomach ulcer, duodenal ulcer, non-bleeding ulcer, gastric erosions and hereditary hemorrhagic telangiectasia. Papilliation of unresectable mucosal-based cancers, coagulation of arteriovenous malformations, ablation of; adenomatous polyps, benign and malignant neoplasm, angiodysplasia, polyps, ulcers, colitis and hemorrhoids. Recanalization of obstructing lesions throughout the gastrointestinal tract, and endoscopic treatment of early oesophageal or gastric cancer. Gynecology: For; endometrial ablation, treatment of menorrhagia, treatment of endometrotic implants, lysis of adhesions, treatment of cervical, vaginal, or vulvar dysplasia, and treatment of cervical, vaginal, or vulvar condyloma. Neurology: For; treatment of arterio-venous malformations, and vascular intracranial tumors like meningiomas and metastatic spinal tumors. Pulmonary: For; treatment of benign and malignant tracheobronchial lesions in the pulmonary airway including; squamous cell carcinoma, papillomas, adenocarcinoma, granulomas, and tracheal stenosis. Urology: Treatment of superficial and invasive bladder carcinoma, urethral and ureteral strictures, benign or malignant lesions of the external genitalia, urethra and anus (condyloma acuminata), bladder neck contracture, and diverticulum. Dermatology: Photocoagulation of vascular lesions for the reduction of lesion size. Treatment of vascular lesions such as; port wine stains (PWS), hemangiomas, angiomas, and venous anomilies. Incision/Excision of soft body tissues. Otolaryngology: Bronchoscopy procedures such as; photocoagulation of endobronchial tumors.

## Device Story

Spectrum Veinlase is a surgical laser system utilizing flashlamp-pumped Nd:YAG technology; delivers 532nm (frequency-doubled) and 1064nm wavelengths. Operates in continuous or 'Captured Pulse' modes for high-energy, short-duration delivery. Used by physicians in clinical/surgical settings for photocoagulation, vaporization, and cutting of soft tissues. System includes cooling, interlocks, and display controls. Output is laser energy delivered via fiber-optic delivery devices to target tissue; enables precise tissue management, hemostasis, and lesion removal. Clinical benefit derived from controlled thermal tissue interaction.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

Flashlamp-pumped Nd:YAG laser; dual wavelength (532nm/1064nm); 'Captured Pulse' technology; includes cooling system, interlock safety controls, and display interface. Standalone surgical laser system.

## Regulatory Identification

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

## Predicate Devices

- Coherent VersaPulse Nd:YAG Solid State Q-Switched
- Thermolase Softlight Nd:YAG Laser
- Laserscope Orion Series Surgical Laser System
- Cynosure PhotoGenica LPIR Dermatologic Laser

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

1 1998 SEP

K98/952

Instruments for Medicine and Diagnostics 3959 South 1820 West Salt Lake City, Utah 84104 (801) 972-0500 (801) 972-4884 (fax) William J McMahan,Ph.D., President Preparation Date: June 01, 1998

#### Summary of Safety and Effectiveness for the:

Combination Neodymium (Nd:)YAG and Solid State Green, Trade Name: Frequency Doubled Nd: Y AG Surgical Laser System.

Common Name: Spectrum Veinlase

Laser Instrument, Surgical Powered - 79GEX Classification Name:

Legally Marketed Predicate Devices for Substantial Equivalence:

Coherent, "VersaPulse" Nd: YAG Solid State Q - Switched.

Thermolase "Softlight" Nd: YAG Laser Hair Removal & Skin Resurfacing Laser.

Laserscope Orion Series Surgical Laser System.

Cynosure "PhotoGenica LPIR" Dermatologic Laser

Rationale for SE: The Spectrum Veinlase and Delivery Devices share similar indications for use, and similar design features including; wavelengths, beam integrity, cooling system, control systems such as interlock devices, and displays. Functional features such as; delivery power, pulse rates, energy type, spot sizes, and areas for treatment are also similar. The legally marketed devices include the above listed systems and their 510(k) number.

{1}------------------------------------------------

# Description of Submitted Device:

The Combination Nd:YAG and Solid State, (Frequency Doubled Nd:YAG) Surgical Laser System is an instrument used in the application of photocoagulation of soft tissue using a 532nm wavelength. The system has the ability to use a 1064nm wavelength for applications including; Coagulation, Vaporization, and Cutting. The system can run both wavelengths in "Captured Pulse" which delivers high energy at very short pulse durations. The laser light is "pumped" by flashlamp technology.

### Technological Characteristics and Substantial Equivalence:

The Coherent, VersaPulse uses O-switched frequency doubled, Q-switched Nd:YAG, and Q-switched Alexandrite: YAG laser energy to deliver 532nm, 1064nm and 755nm wavelengths. The VersaPulse delivers the same wavelength, similar average power, pulses of equivalent duration, and treatment spots of equivalent diameter. The indications for use are also similar.

TheThermolase Softlight Laser uses the identical wavelength. A Nd: YAG Rod, the output of which is 1064nm. The Softlight laser uses a carbon-based cream to aid in the removal of unwanted body hair and for skin resurfacing.Similar average power, pulses of equivalent duration, and treatment spots of equivalent diameter.

The Laserscope Orion Series Laser System offers the same 532/1064 capability and is capable of the pulsed power technology that we are offering.It is indicated in the treatment of dark ink tatoos. The laser delivers similar strength, similar average power, pulses of equivalent duration, and treatment spots of equivalent diameter. The "Starpulse" allows it to deliver high energy at short pulse durations.

The Cynosure PhotoGenica LPIR Laser uses a 755nm wavelength, obtained from a Flashlamp-Excited Solid State Pulsed Laser is indicated in the treatment of leg veins that are between 0.6 mm to 3.0 mm in size. The LPIR uses a HENE (CW) 543nm green aiming beam. Other areas of the PhotoGenica LPIR including; pulse duration, and treatment spots are equally similar.

{2}------------------------------------------------

treatment of leg veins that are between 0.6 mm to 3.0 mm in size. The LPIR uses a HENE (CW) 543nm green aiming beam. Other areas of the PhotoGenica LPIR including; pulse duration, and treatment spots are equally similar.

## Nonclinical Performance Data:

None

Clinical Performance Data:

None

Conclusion:

The Combination Nd: YAG and Solid State Green (Frequency Doubled Nd: YAG) Surgical Laser System is substantially equivalent to other existing surgical laser systems in commercial distribution for the treatment of Indicated uses listed.

Additional Information:

None requested at this time.

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle or other bird-like figure, with three overlapping profiles suggesting a sense of community or interconnectedness.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

1 1998 SEP

William J. McMahan, Ph.D. President Instruments for Medicine and Diagnostics 3959 West 1820 South Salt Lake City, Utah 84104

Re: K981952

> Trade Name: Combination Neodymium (Nd:) Yag and Solid State Green, Frequency Doubled Nd: YAG Surgical Laser System Regulatory Class: II Product Code: GEX Dated: June 1, 1998 Received: June 3, 1998

Dear Dr. McMahan:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

{4}------------------------------------------------

#### Page 2 - William J. McMahan, Ph.D.

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".

Sincerely yours,

Celia M. Witten, PhD, M.D.

Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

510(k) Number (if known): 上りしい ( 5)

Device Name:

Combination Nd:YAG and Solid State Green (Frequency Doubled Nd:YAG) Surgical Laser System

Indications For Use:

## 532nm Wavelength:

| General Surgery:                                           | Coagulation, hemostasis, vaporization, excision, and incision of<br>tissue. Photocoagulation of Vessels/Veins up to 1.5 mm                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
|------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Endoscopic &<br>Laparoscopic:                              | Excising, Coagulation or Vaporization of tissue during<br>Endoscopic or Laparoscopic procedures, Cholecystectomy and<br>Appendectomy.                                                                                                                                                                                                                                                                                                                                                                                                                                                   |
| Gynecology:                                                | Ablation or lysis of intra-abdominal tissues via laparotomy or<br>laparoscope. Ablation of endometrial implants, lysis of adhesions,<br>ablation of the uterosacral ligaments, cutting/coagulating,<br>treatment of uterine polyps and fibroids, salpingo-ophorolysis, and<br>transection of uterine septa.                                                                                                                                                                                                                                                                             |
| Laryngology:                                               | Photocoagulation or Vaporization of soft or fibrous tissue such as;<br>hereditary hemorrhagic telangiectasia (vascular lesions), pigmented<br>structures that are highly vascular, and tonsillectomy.                                                                                                                                                                                                                                                                                                                                                                                   |
| Otology:                                                   | For; stapedotomy, stapedectomy, tympanoplasty with fascia graft,<br>myringotomies, control of bleeding, removal of osseous disease of<br>the external canal, removal of acoustic neuromas, lysis of adhesions<br>and soft tissue adhesion, in both micro- and macro- otologic<br>procedures.                                                                                                                                                                                                                                                                                            |
| Rhinology:                                                 | For; control of epistaxis, turbinate reduction (excludes bone),<br>treatment of endonasal polyps, hereditary hemorrhagic<br>telangiectasia, synechia, hemangiomas, telangiectasia, vaporize of<br>maxillary sinus cysts and polyps, treatment of papillomas and<br>granulomas, endonasal dacryocystorhinostomy, treatment of lesions<br>within the nose and sinus, creation of nasoantral window and<br>coagulation of vessels or veins up to 1.5 mm in diameter.                                                                                                                       |
| Urology:                                                   | Coagulation of veins or vessels up to 1.5 mm in diameter,<br>management of condyloma acuminata, carcinoma in situ, small<br>papillary bladder tumors, port wine stains, hemangioma of the<br>external genitalia or bladder and urethral recanalization.                                                                                                                                                                                                                                                                                                                                 |
| Prescription Use<br>(Per 21 CFR 801.109)                   | OR<br>Counter Use                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |
| Indications for use, Spectrum Veinlase (Division Sign-Off) | Page 1 of 3<br>Attachment "E"                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
|                                                            | Division of General Restorative Devices<br>K981952<br>510(k) Number                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
| Neurosurgery:                                              | For; dorsal root entry zone lesions, spinal intramedullary tumor,<br>medulloblastomas, acoustic neuromas, intracranial meningiomas,<br>ventricular ependymomas, choroid plexus, carcinomas,<br>hemangioblastomas, ependymoma extending into the brain stem,<br>and intra- / extra- axial spinal cord tumors.                                                                                                                                                                                                                                                                            |
| Ophthalmology:                                             | For; posterior and anterior treatment procedures including;<br>diabetic retinopathy, retinal detachments, ablate tissues of the iris<br>or trabeculum, peripheral iridectomy and iridotomy,<br>trabeculoplasty, and senile macular degeneration. Other conditions<br>of the retina in which the laser is deemed useful involving<br>endophotocoagulation. Extraorbital procedures such as; coagulation<br>of vessels or veins up to 1.5 mm in diameter, extra orbital<br>pigmented or venous lesions; port wine hemangiomas or<br>telangiectasia. Treatment for chronic dacryocystitis. |
| Dermatology:                                               | For; treating vascular lesions, dermatologic lesions, and/or<br>cutaneous lesions such as; facial or extremities telangiectasias,<br>venous anomalies, leg veins up to 1.5 mm in diameter, and port<br>wine stains.                                                                                                                                                                                                                                                                                                                                                                     |

{6}------------------------------------------------

#### 1064nm Wavelength:

| General Surgery:     | For; incision or excision of all soft body tissues including; skin,<br>subcutaneous and breast tissue, striated and smooth muscle, tendon<br>and fascia, cartilage, mucous membrane, lymphatic tissue, internal<br>organs and glands of the gastrointestinal, genitourinary,<br>pulmonary, endocrine and exocrine systems, as well as cancers of<br>theses systems. Treatment of larger and deeper vessels/veins up to<br>3.0 mm in diameter, 4.0 to 7.0 mm in depth. |
|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| ENT, Head<br>& Neck: | For; incision or excision of all soft body tissues including; skin,<br>subcutaneous tissue, striated and smooth muscle, tendon and fascia,<br>cartilage, mucous membrane, lymphatic tissue, organs and glands<br>of the ENT system and access via endoscope, microscope or direct                                                                                                                                                                                     |

For; esophageal neoplastic obstructions such as; squamous cell Gastroenterology: carcinoma, and adenocarcinoma, upper and lower GI bleeding such as; varices, esophagitis, esophageal ulcer, Mallory-Weiss tear, gastric ulcer, stomach ulcer, duodenal ulcer, non-bleeding ulcer, gastric erosions and hereditary hemorrhagic telangiectasia. Papilliation of unresectable mucosal-based cancers, coagulation of arteriovenous malformations, ablation of; adenomatous polyps, benign and malignant neoplasm, angiodysplasia, polyps, ulcers, colitis and hemorrhoids. Recanalization of obstructing lesions throughout the gastrointestinal tract, and endoscopic treatment of early oesophageal or gastric cancer.

visualization.

Prescription Use
OR Over-The-Counter Use
(Per 21 CFR 801.109)
Page 2 of 3
Indications for use, Spectrum Veinlase (Division Sign-Off) Attachment "B"
Division of General Restorative Devices
510(k) Number K981952

{7}------------------------------------------------

| Gynecology:     | For; endometrial ablation, treatment of menorrhagia, treatment of<br>endometrotic implants, lysis of adhesions, treatment of cervical,<br>vaginal, or vulvar dysplasia, and treatment of cervical, vaginal, or<br>vulvar condyloma.            |
|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Neurology:      | For; treatment of arterio-venous malformations, and vascular<br>intracranial tumors like meningiomas and metastatic spinal tumors.                                                                                                             |
| Pulmonary:      | For; treatment of benign and malignant tracheobronchial lesions in<br>the pulmonary airway including; squamous cell carcinoma,<br>papillomas, adenocarcinoma, granulomas, and tracheal stenosis.                                               |
| Urology:        | Treatment of superficial and invasive bladder carcinoma, urethral<br>and ureteral strictures, benign or malignant lesions of the external<br>genitalia, urethra and anus (condyloma acuminata), bladder neck<br>contracture, and diverticulum. |
| Dermatology:    | Photocoagulation of vascular lesions for the reduction of lesion size.<br>Treatment of vascular lesions such as; port wine stains (PWS),<br>hemangiomas, angiomas, and venous anomilies. Incision/Excision of<br>soft body tissues.            |
| Otolaryngology: | Bronchoscopy procedures such as; photocoagulation of<br>endobronchial tumors.                                                                                                                                                                  |

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE)

Division Sign-Off) Wision of General Restorative Devices 51000 Number

Prescription Use
(Per 21 CFR 801.109)(
Indications for use, Spectrum Veinlase

ﺎ

---

**Source:** [https://fda-staging.innolitics.com/device/K981952](https://fda-staging.innolitics.com/device/K981952)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).