MYELOTEC VIDEO GUIDED CATHETER

K980734 · Myelotec, Inc. · HRX · Aug 11, 1998 · Orthopedic

Device Facts

Record IDK980734
Device NameMYELOTEC VIDEO GUIDED CATHETER
ApplicantMyelotec, Inc.
Product CodeHRX · Orthopedic
Decision DateAug 11, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.1100
Device ClassClass 2
AttributesTherapeutic

Indications for Use

When used with a fiberoptic endoscope, this device can be used in the lumbar and sacral spine for observing epidural anatomy, pathology and delivery of drugs approved for epidural indications.

Device Story

Myelotec Video Guided Catheter (VGC) is a flexible, steerable, double-lumen catheter designed for epidural space access. Operated by physicians in hospital or surgery center settings, the device is inserted via the sacral hiatus. One lumen accommodates a flexible fiberoptic endoscope for visual examination of epidural anatomy and pathology; the second lumen allows for saline injection to expand the epidural space and the delivery of physician-selected therapeutic agents. The steering mechanism enables precise navigation of the catheter tip through soft tissues to the site of neural distress. Visual feedback from the endoscope assists the physician in diagnosing causes of pain and guiding targeted drug delivery, potentially improving therapeutic outcomes for patients with spinal conditions.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Flexible double-lumen catheter with integrated steering mechanism. Materials: unspecified flexible polymers. Dimensions: 1 mm diameter per lumen; 0.039 inch inner diameter. Connectivity: compatible with fiberoptic endoscopes. Sterilization: sterile, single-use. Energy source: manual mechanical steering. No software or electronic components.

Indications for Use

Indicated for patients requiring observation of epidural anatomy and pathology in the lumbar and sacral spine, and for the delivery of drugs approved for epidural indications.

Regulatory Classification

Identification

An arthroscope is an electrically powered endoscope intended to make visible the interior of a joint. The arthroscope and accessories also is intended to perform surgery within a joint.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ AUG 1 1 1998 ## 510(k) NOTIFICATION SUMMARY MYELOTEC, INC. 4000 NORTHFIELD WAY, SUITE 900 ROSWELL, GA 30076 980734/ ### CONTACT: THOMAS DUNKLE PHONE: (770) 664-4656 (EXT. 20) FAX: (770) 664-4363 ## DATE PREPARED: July 13, 1998 DEVICE NAME: PROPRIETARY NAME: CLASS: PANEL: CLASSIFICATION NAME: PRODUCT CODE: REGULATION NUMBER: PREDICATE DEVICE: CATHETER MYELOTEC VIDEO GUIDED CATHETER II ANESTESIOLOGY CATHETER, CONDUCTION, ANESTHESIA 73BSO 868.5120 RACZ Tun-L-Kath 510(k) number - K954584 #### DESCRIPTION AND INTENDED USES: The MYELOTEC VIDEO GUIDED CATHETER (VGC) consists of a flexible double lumen catheter, steering handle and associated ports for access to the lumens. The catheter has a built in steering mechanism that allows for guiding the soft tip through the epidural space and soft tissues for optimal access to the source of distress. Each lumen is one (1) mm in diameter. The design allows the use of a flexible fiber optic endoscope for visual examination of the area and surrounding tissues at the distal end of the catheter. This visual examination then allows the physician to diagnose the potential causes of neural distress and pain. The port on the second lumen allows the injection of saline to expand the space and expose the source of distress for viewing and treatment. The port also facilitates the connection of syringes to deliver physician selected therapeutic agents as appropriate to their diagnosis. #### NEW INDICATIONS FOR USE: When used with a fiberoptic endoscope, this device can be used in the lumbar and sacral spine for observing epidural anatomy, pathology and delivery of drugs approved for epidural indications. #### EQUIVALENCE: ### COMPARISON TABLE | ATTRIBUTE/name: | MYELOTEC VGC | RACZ Tun-L Kath | |----------------------|-------------------------|-------------------------| | WHERE USED | Hospital/surgery center | Hospital/surgery center | | SUPPLIED STERILE | YES | YES | | SINGLE USE | YES | YES | | INSERTION POINT | SACRAL HIATUS | SACRAL HIATUS | | MODE OF ENTRY | 8 FR. INTRODUCER | 18 GAGE NEEDLE | | CATHETER LENGTH | ABOUT 12 INCES | ABOUT 33 INCHES | | LUMEN INNER DIAMETER | 0.039 INCHES | 0.021 INCHES | | NUMBER OF LUMENS | 2 | 1 | | ENDOSCOPE CAPABLE | YES | NO | | STEERABLE | YES | NO | {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal features an abstract design of an eagle with three human profiles incorporated into its body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 AUG | | 1998 Mr. Thomas A. Dunkle Director Quality Assurance/Regulatory Affairs Myelotec, Inc. 4000 Northfield Way, Suite 900 Roswell, Georgia 30076 Re: K980734 Trade Name: Myelotec Video Guided Catheter Regulatory Class: II Product Code: HRX Dated: May 28, 1998 Received: May 29, 1998 Dear Mr. Dunkle: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {2}------------------------------------------------ Page 2 - Mr. Thomas A. Dunkle This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours. Russell H. Morgan 2 Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ # 510(k) NOTIFICATION - MYELOTEC, INC. ROSWELL, GA. 30076 # K980734 ## INTENDED USE/INDICATIONS INTENDED USE/INDICATIONS - when used with a fiberoptic endoscope, this device can be used for INTENDED ODEXINDICATIONS will and delivery of drugs approved for epidural indications. Russell S. Lyons for JZD Prescription Use (Per 21 CFR 801.109) ッ
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...