ATHENA 1:1 CONTRA ANGLE, ATHENA 4:1 CONTRA ANGLE, ATHENA 16:1 CONTRA ANGLE, ATHENA 64:1 CONTRA ANGLE, ATHENA 16-: CONTRE
K974670 · Athena Technology, Inc. · EFB · Mar 13, 1998 · Dental
Device Facts
Record ID
K974670
Device Name
ATHENA 1:1 CONTRA ANGLE, ATHENA 4:1 CONTRA ANGLE, ATHENA 16:1 CONTRA ANGLE, ATHENA 64:1 CONTRA ANGLE, ATHENA 16-: CONTRE
Applicant
Athena Technology, Inc.
Product Code
EFB · Dental
Decision Date
Mar 13, 1998
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.4200
Device Class
Class 1
Attributes
Therapeutic
Indications for Use
Attachments are used in conjunction with a 20R "E" type slow speed handpiece motor to prepare carious teeth for restorations; to perform prophylaxis or other general procedures performed by the dentist in the oral cavity or in a laboratory environment.
Device Story
Athena dental handpiece attachments (nosecones and contra angles) connect to 20R "E" type slow speed motors; they transmit rotational power from the motor to dental burs or prophy angles. Operation involves a drive dog and input shaft; 1:1 models use direct drive, while speed reduction models (4:1, 16:1, 64:1) utilize planetary gear systems to increase torque and reduce output RPM. The clinician operates the device in a dental clinic or lab to perform restorative or prophylactic procedures. The collet assembly, operated by a ring with a detent locking system, secures the dental instrument. These devices provide the mechanical interface necessary for dentists to perform precise tooth preparation and cleaning, benefiting patients by enabling restorative and preventative dental care.
Clinical Evidence
Bench testing only. Sterilization validation was performed using a Pelton & Crane Validator 8 autoclave (132°C, 210 kPa, 12 minutes). Biological indicators (Bacillus stearothermophilus spore strips) confirmed sterility after the cycle. Life cycle testing demonstrated a minimum of 500 autoclave cycles.
Technological Characteristics
Mechanical dental handpiece attachments. Materials: Aluminum (Type 2011/6016), stainless steel (300 series/416), and brass. Energy source: Pneumatic (air-driven motor). Design: Direct drive (1:1) or planetary gear systems for speed reduction (4:1, 16:1, 64:1). Features: Four ball bearing construction, collet assembly with detent locking. Connectivity: Compatible with "E" type, Midwest, and Star motors. Sterilization: Fully autoclavable up to 135°C.
Indications for Use
Indicated for use by dentists to prepare carious teeth for restorations, perform prophylaxis, and conduct general dental procedures in the oral cavity or laboratory environment.
Regulatory Classification
Identification
A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows a sequence of handwritten digits and letters. The sequence starts with the letter 'K', followed by the numbers '9', '7', '4', '1', '6', '7', and '0'. The handwriting style is somewhat irregular, with variations in stroke thickness and letter formation.
## Section 8: 510(k) Summary
MAR 1 3 1998
Submitted By: Athena Technology, Inc. 984 N. Amelia Ave. San Dimas, CA 91773
(800) 253-1771
Contact: William T. Anderson
## Date Prepared:
Device Name: Trade or Proprietary Name - Athena 1:1 Contra Angle, Athena 4:1 Speed Reduction Contra Angle, Athena 16:1 Speed Reduction Contra Angle, Athena 16:1 Speed Reduction Contra Angle to fit Midwest, Athena 64:1 Speed Reduction Contra Angle, Athena Heavy Duty 1:1 Four Ball Bearing Straight Nosecone for All E Type Motors, Athena Heavy Duty 4:1 Four Ball Bearing Straight Nosecone for All E Type Motors. Athena Heavy Duty 1:1 Four Ball Bearing Straight Nosecone for Midwest Motors, Athena Heavy Duty 4:1 Four Ball Bearing Straight Nosecone for Midwest Motors, Athena Heavy Duty 1:1 Four Ball Bearing Straight Nosecone for Star Motors, Athena Heavy Duty 4:1 Four Ball Bearing Straight Nosecone for Star Motors. Common or Usual Name - Straight Nosecones and Contra Angles Classification Name - Dental Handpiece Attachments
Identification: The following devices are identified to be equivalent to Athena attachments, nosecones and contra angles:
- A. Lynx attachments marketed by MTI Precision Products, 175 Oberlin North Avenue, Lakewood, New Jersey 08701; and
- B. Champion attachments marketed by Champion Dental Products Inc., 1941 Miraloma, Placentia, California 92870; and
- C. NSK attachments marketed by NSK America Corporation, 700 B Cooper Court, Schaumburg, Illinois 60173
- D. Midwest attachments marketed by Dentsply Midwest, 901 West Oakton Street, Des Plaines, Illinois 60018; and
- E. Star attachments marketed by Star Dental (Division of DEN-TAL-EZ, Inc.), 1816 Colonial Village Lane, Lancaster, Pennsylvania 17601.
{1}------------------------------------------------
Description: Athena nosecones include models to fit "E" type slow speed motors, Midwest and Star slow speed handpiece in two versions, the standard 1:1 non-reduction model and the 4:1 speed reduction model. These have four ball bearing construction; durable stainless steel chuck and operating mechanism. Uses standard handpiece burs, disposable and metal prophy angles.
Device Function: Power is delivered to the nosecone through the drive dog and input shaft, usually rotating at a nominal 20,000 RPM. The rotation is carried through a direct drive (in the case of a 1:1 unit) or through a planetary gear system to control the overall speed reduction and output RPM delivered to the attachment placed and locked in the nosecone collet assembly.
Significant Physical and Performance Characteristics: The exploded drawing (attached) illustrates the placement and function of the various elements and parts. Drive power rotates the input shaft which in the 1:1 system directly drives the collet system. In the case of a geared system, drive power rotates the input shaft which rotates a "sun" gear element of the planetary gear system. The "ring" gear of the planetary gear system is locked and is prevented from rotating. The planet gears rotate at an RPM which is controlled by the ratio of teeth in the ring gear and sun gear. The output of the planetary system results in the carrier of the planets rotating and is provided to the collet system directly. By controlling the gear ratio of the planetary system, a wide range of rotational speeds is available. As the speed is reduced , the output torque is similarly increased. The collet is operated by rotating the "collet operating ring". Positive locking is provided by a detent system to prevent inadvertent opening of the collet during operation.
Materials Used: The nosecone is principally made of the following materials: Aluminum for the rear housing and color bezel denoting the gear ratio: stainless steel for all other metal parts except bearings; and instrument quality stainless steel for the bearings.
Material Physical Properties: Aluminum Type 2011 or 6016 is used. Physical properties associated with these materials is defined by ASTM specification. It is commonly used in medical and dental instruments and devices. Stainless steel Type 300 series and 416 is used. Physical properties associated with these is defined by ASTM specification. It is commonly used in medical and dental instruments and devices.
Athena contra angles include models to fit "E" type slow speed motors and Midwest slow speed handpieces. "E" type models include a standard 1:1 non-reduction model and three speed reduction models 4:1, 16:1 and 64:1. The Midwest version is a 16:1 speed reduction. They convert a straight handpiece to an angle for increased access in the oral cavity. The reduction angles use stainless steel gears and four ball bearings for durability and longevity. Uses latch type heads.
{2}------------------------------------------------
Device Function: Power is delivered to the contra angle through the drive dog and input shaft, usually rotating at a nominal 20,000 RPM. The rotation is carried through either a direct drive (in the case of a 1:1) unit or through one or more planetary gear systems operating sequentially to control the overall speed reduction and output RPM delivered to the attachment placed n the output of the contra angle.
Significant Physical and Performance Characteristics: The exploded drawing (attached) illustrates the placement and function of the various elements and parts. Drive power rotates the input shaft, in the 1:1 system directly drives the output shaft through the angled fitting and associated gears. In the case of a geared system, drive power rotates the input shaft which rotates a "sun" gear element of the first planetary gear system. The "ring" gear of the planetary gear system is locked and prevented from rotating. The planet gears rotate at an RPM which is controlled by the ratio of teeth in the ring hear and on the sun gear. The output of the planetary system results in the carrier of the planets rotating and, in the case of a single planetary system is provided to an "angle" fitting and associated gears and shaft to the output shaft directly. If the system includes more than one planetary system, the output of the first becomes the input to the next planetary system until the output is finally directed to the angle fitting and the output shaft. By controlling the gear ratio of the planetary system(s) a wide range of rotational speeds is available. As the speed is reduced, the output torque is similarly increased.
Materials Used: The contra angles are principally made of the following materials: Aluminum for the rear housing and color bezel denoting the gear ratio; stainless steel for all other metal parts except for the bearings which are made of instrument quality stainless steel; and brass for the output bearing carrier.
Material Physical Properties: Aluminum Type 2011 or 6016 is used. The physical properties associated with these materials is defined by ASTM specification. It is commonly used in medical and dental instruments and devices. Stainless steel Type 300 series and 416 is used. The physical properties associated with these materials is defined by ASTM specification. It is commonly used in medical and dental instruments and devices. Standard and brass alloys are used. The physical properties associated with these are defined by ASTM specification. Usually the material is in the "half hard" heat treat condition to provide sufficient strength and wear characteristics as required by the application.
All are fully autoclavable (up to 135°C).
Statement of the Intended Use: Attachments are used in combination with a 20R "E" type slow speed handpiece motor to prepare carious teeth for restoration; to perform prophylaxis or other general procedures performed by the dentist in the oral cavity.
{3}------------------------------------------------
Technological Characteristics: Athena attachments are similar to predicate devices in indications for use, design (Nosecones: E type/Midwest/Star coupling, mechanically driven, accepts U type attachments as well as standard burs. Contra angles: E type/ Midwest coupling, mechanically driven, accepts standard 14 tooth attachments.); material (aluminum, stainless steel and brass); energy source (air).
Sterilization Test and Anaylsis: Autoclave procedures for the Compact Nosecone, 1:1 Contra Angle, 64:1 Contra Angle, Heavy Duty 1:1 Straight Nosecone and Heavy Duty 4:1 Straight Nosecone were conducted in a Pelton & Crane Validator 8 at Athena Technology, Inc., 984 N. Amelia Ave., san Dimas, CA 91773, (800) 253-1771. Biological indicator used was Sportrol Spore Strip @106, bacillus stearothermophilus. Manufacturers lot #S51703 with an expiration date of May 1999. The biological testing facility was Namsa, 9 Morpan, Irvine, CA 92718, (714) 951-3110.
A spore strip was inserted into the drive tubes of one each of the above named devices. The devices were placed in Athena standard autoclave bags and then placed in the autoclave according to the recommendations received with the spore strips.
The devices were placed on a tray with a pair of tweezers to be used for the removal of the spore strips. In addition, a stainless steel plate was inserted into the autoclave to provide a sterile surface for the device on the removal from the autoclave.
The sterilization cycle in the Pelton & Crane Validator 8 consisted of 12 minutes at 132 degrees Celsius and 210 kPa pressure.
The devices were removed from the autoclave using sterile gloves and the spore strips removed with the sterile tweezers. The spore strips were sealed in individual bags and identified. They were then forwarded to Namsa for incubation.
The spore strips were cultured at Namsa for a period of 7 days using the procedure/test medthod S-04491-01-00/Immersion. The spore strips tested sterile by Namsa (report included.)
In conclusion, Athena devices ssterilized in a Pelton & Crane Validator 8 or similar autoclave at 132 degrees Celsius at 210 kPa for 12 minutes will be sterile.
Life Cycle Estimates: The Athena Compact Nosecone, 1:1 Contra Angle, 64:1 Contra Angle, Heavy Duty 1:1 Straight Nosecone and Heavy Duty 4:1 Straight Nosecone have estimated minimum life cycles of 500 cycles when autoclaved for 12 minutes at 132 degrees Celsius and 210 kPa pressure.
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle-like symbol with three curved lines representing the body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the symbol.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 1 3 1998
Mr. William T. Anderson ·President Athena Technology, Incorporated 984 North Amelia Avenue 91773 San Dimas, California
K974670 Re : Athena 1:1 Contra Angle, Athena 4:1 Contra Trade Name: Angle, Athena 16:1 Regulatory Class: I Product Code: EFB December 12, 1997 Dated: Received: December 15, 1997
Dear Mr. Anderson:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title.21, Parts.800_to 895_ A . . . . . . substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical General regulation (21 CFR Part 820) and that, Devices: through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory In addition, FDA may publish further announcements action. concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531
{5}------------------------------------------------
Page 2 - Mr. Anderson
through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or requlations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diaqnostic devices), please contact the Office of Compliance at (301) 594-4618. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to one regarier notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.qov/cdrh/dsmamain.html".
Sincerely yours,
Timothy A. Ulatowski
Timo ಗ Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radioloqical Health
Enclosure
{6}------------------------------------------------
## Section 3: Statement of Indications for Use
Intended Use: Attachments are used in conjunction with a 20R "E" type slow speed handpiece motor to prepare carious teeth for restorations; to perform prophylaxis or other general procedures performed by the dentist in the oral cavity or in a laboratory environment.
Susan Rumer
(Division Sign-Off) Division of Dental, Infection Control, and General Hospital D 510(k) Number
Prescription Use (Per 21 CFR 801.109)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.