X-SIGHT DIGITAL IMAGING SYSTEM

K974134 · Stallion Technologies, Inc. · LLZ · Jan 27, 1998 · Radiology

Device Facts

Record IDK974134
Device NameX-SIGHT DIGITAL IMAGING SYSTEM
ApplicantStallion Technologies, Inc.
Product CodeLLZ · Radiology
Decision DateJan 27, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.2050
Device ClassClass 2
AttributesSoftware as a Medical Device

Indications for Use

The X-Sight device is indicated for reading, storing, and converting image data from fluoroscopic x-ray systems.

Device Story

X-Sight Digital Imaging System functions as a digital interface for fluoroscopic x-ray systems. Device reads, stores, and converts analog or digital image data from fluoroscopic sources. Used in clinical settings by healthcare professionals to manage radiological image data. Output facilitates viewing and storage of fluoroscopic images, supporting diagnostic workflows. Benefits include improved image data management and integration within radiological environments.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Digital imaging system for fluoroscopic x-ray data. Functions include reading, storing, and converting image data. Connectivity involves integration with fluoroscopic x-ray systems.

Indications for Use

Indicated for reading, storing, and converting image data from fluoroscopic x-ray systems. No specific patient population, age, or disease state constraints provided.

Regulatory Classification

Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features the department's name in a circular arrangement around a stylized emblem. The emblem consists of a symbol that resembles a stylized human figure with outstretched arms, representing care and protection. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Marshall Ma President Stallion Technologies, Inc. 4324 Loveland Drive Liverpool, NY 13090-6862 Re: K974134 X-Sight Digital Imaging System Dated: October 29, 1997 Received: November 3, 1997 Regulatory class: Unclassified Procode: 90 LLZ JAN 27 1998 Dear Mr. Ma: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the inclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21. Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsmamain.html"......... Sincerely yours, W.Lilian Yin, Ph.D. Lillian Yin, Ph.D. Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health {1}------------------------------------------------ Page 1 of 1 ## INDICATION FOR USE 510(k) Number: K974134 Device Name: X-Sight Medical Digital Imaging System Indication For Use: The X-Sight device is indicated for reading, storing, and converting image data from fluoroscopic x-ray systems. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Javril a. Segerson (Division Sign-Off) Division of Reproductive, Abdominal, ENT, and Radiological Devices 510(k) Number K974134 Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...