The Orthofix Femoral Nailing System is indicated for the following: traumatic fractures; pathological fractures; refractures; non-unions; reconstructive surgery; and bone transport.
Device Story
Orthofix Femoral Nailing System consists of surgical grade stainless steel intramedullary nails, locking screws, and end caps; includes associated surgical instrumentation (reamers, drill bits, guides, impactors). Used by orthopedic surgeons in clinical/hospital settings for fracture fixation and bone reconstruction. Nails are inserted into the femoral canal; locking screws provide stability; end caps prevent tissue ingrowth. System facilitates bone healing and structural support for patients with femoral fractures or bone defects. Output is physical stabilization of the bone; clinical decision-making relies on surgeon assessment of fracture type and patient anatomy.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Materials: surgical grade stainless steel. Components: intramedullary nails (9-13mm diameters), locking screws (self-tapping), end caps. Instrumentation: drill bits, reamers, awls, trocars, guide wires, depth gauges, impactors/extractors. Mechanical fixation device; no energy source or software.
Indications for Use
Indicated for patients requiring stabilization of traumatic fractures, pathological fractures, refractures, non-unions, reconstructive surgery, and bone transport.
Regulatory Classification
Identification
An intramedullary fixation rod is a device intended to be implanted that consists of a rod made of alloys such as cobalt-chromium-molybdenum and stainless steel. It is inserted into the medullary (bone marrow) canal of long bones for the fixation of fractures.
Howmedica Grosse & Kempf Locking Nail System (K860756)
Smith & Nephew Richards Femoral Interlocking Nail System
Submission Summary (Full Text)
{0}------------------------------------------------
K97-39421
DEC 19 1997
## 510(k) SUMMARY1 Orthofix® Femoral Nailing System October 14, 1997
This summary is provided in accordance with the Safe Medical Devices Act of 1990 (SMDA). The information provided in the 510(k), premarket notification was in accordance with 21 CFR 807.87 and the SMDA.
#### Submitter of 510(k) 1.
Robert L. Sheridan (Consultant) Vice President, Device Evaluation C.L. McIntosh & Associates, Inc. 12300 Twinbrook Parkway, Suite 625 Rockville, MD 20852
Telephone: (301) 770-9590 Facsimile: (301) 770-9584
#### 2. Name of Device:
- A. Trade/Proprietary Name:
Orthofix® Femoral Nailing System
- B. Common/Usual Name:
Femoral Nailing System
- C. Classification Name:
"Intramedullary Fixation Rod" (21 CFR 888.3020).
#### 3. Sponsor/Manufacturer:
ORTHOFIX Srl. Via delle Nazioni 9 37012 Bussolengo (VR), Italy
Any statement made in conjunction with this submission regarding a determination of substantial equivalence to any other product is intended only to refer to whether the product can be lawfully marketed without pre-market approval or reclassification and is not interpreted as an admission or any other type of evidence in patent infringement litigation. (Establishment Registration and Premarket Notification Procedures, Final Regulation, Preamble, August 23, 1977, FR 42520 (Docket No. 76N-0355)
{1}------------------------------------------------
Rolando Stanghellini, Director of Quality Assurance Attention:
011-39-45-6767030 Telephone: 011-39-45-6767135 Facsimile:
#### Reason for Submitting the 510(k) 4.
We are submitting this document on behalf of our client, Orthofix Srl. (Orthofix), of Bussolengo, Italy. We are hereby notifying you of Orthofix's intention to commercially distribute its Femoral Nailing System for the first time in the U.S. Orthofix currently distributes a comparable nailing system for the tibia, Tibial Nailing System (K961027). Like our tibial nailing system and predicate devices our femoral nailing system includes a series of nails of varying diameters and lengths, locking screws and end caps, as well as the instruments and accessories used in their implantation and removal.
#### રું Device Description
The Orthofix femoral nail is manufactured from surgical grade stainless steel. The nail is available in five diameters, 9, 10, 11, 12 and 13 mm and varying lengths. The nails have two proximal and two distal locking holes. The screws are also manufactured from surgical grade stainless steel. They have a self tapping thread and are available in varying lengths. End caps are provided which screw into the nail's proximal end, preventing tissue ingrowth and allowing for easier explantation. The end caps are also manufactured from surgical grade stainless steel.
The system includes various instruments and accessories used during the implantation and removal of the nail and locking screws. They include drill bit kits, hand and flexible reamers, an awl, trocars, guide wires, a bone depth gauge, a slap hammer impactor/extractor, an X-ray overlay, a metal ruler, a screw extractor, sterilization boxes, guides, wrenches and other tools.
#### Intended Use 6.
The Orthofix Femoral Nailing System is indicated for the following: traumatic fractures; pathological fractures; refractures; non-unions; reconstructive surgery; and bone transport.
#### 7. Substantial Equivalence
The information provided in this submission demonstrates that the Orthofix Femoral Nailing System is substantially equivalent to legally marketed predicate femoral nailing systems. First, most of the components and instrumentation in this system are either identical to or comparable to those in our Tibial Nailing System (K961027). Secondly, these components and instrumentation are substantially equivalent to those provided in the predicate systems. Two such predicate devices are the Howmedica Grosse & Kempf
{2}------------------------------------------------
Locking Nail System (K860756) and Smith & Nephew Richards Femoral Interlocking Nail System. The Orthofix Femoral Nailing System and the legally marketed predicate devices are substantially equivalent in intended use, indicated use, material composition, size and shape.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is an abstract symbol resembling an eagle or a stylized human figure, composed of flowing lines. The symbol is black, and the background is white.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC 19 1997
Mr. Robert L. Sheridan 'Vice President, Device Evaluation C.L. McIntosh & Associates, Inc. Representing Orthofix Srl 12300 Twinbrook Parkway, Suite 625 Rockville, Maryland 20852
Re: K973944 Orthofix® Femoral Nailing System Requlatory Class: II Product Code: HSB Dated: October 14, 1997 Received: October 16, 1997
Dear Mr. Sheridan:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Requlation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP requlation may result in requlatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{4}------------------------------------------------
### Page 2 - Mr. Robert L. Sheridan
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to
premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
C. Colm M. Witten, Ph.D.
Cella M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
## Indications For Use
Device Name: Orthofix Femoral Nailing System
Indications For Use:
The Orthofix Femoral Nailing System is indicated for the following: traumatic fractures; pathological fractures; refractures; non-unions; reconstructive surgery; and bone transport.
# (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use: (Per 21 CFR 801.109) OR
Over-The-Counter:
to coello
(Optional Format 1-2-96)
(Division Sign-Off)
Division of General Restorative Devices
510(k) Number K973944
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.