K973869 · Trace America, Inc. · CKA · Jan 7, 1998 · Clinical Chemistry
Device Facts
Record ID
K973869
Device Name
TRACE REAGENT LINE FOR THE COBAS MIRA
Applicant
Trace America, Inc.
Product Code
CKA · Clinical Chemistry
Decision Date
Jan 7, 1998
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 862.1030
Device Class
Class 1
Indications for Use
Intended for the the In Vitro, quantitative determination of ALT (L-Alanine;2-Oxoglutarate Aminotransferase EC2.6.1.2) in human serum on the Cobas MIRA® clinical chemistry system. This alanine aminotransferase (ALT/SGPT) test system is a device intended to measure the activity of the enzyme alanine aminotransferase (ALT) (also known as a serum glutamic pyruvic transaminase or SGPT) in serum and plasma. Alanine aminotransferase measurements are used in the diagnosis and treatment of certain liver diseases (e.g. viral hepatitus and cirrhosis) and heart diseases. CFR 862.1030
Device Story
TRACE Reagent Line consists of chemical reagents for use on the Cobas MIRA clinical chemistry system. Reagents are used by laboratory professionals in clinical settings to perform quantitative in vitro diagnostic assays on patient serum, plasma, or urine samples. The system automates the mixing of reagents with patient samples; chemical reactions produce measurable changes (e.g., colorimetric or enzymatic activity) detected by the analyzer. The analyzer provides quantitative results to the clinician, who uses these values to diagnose and monitor conditions such as liver disease, pancreatitis, diabetes, renal failure, and electrolyte imbalances. The device facilitates rapid, standardized diagnostic testing, aiding in clinical decision-making and patient management.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
In vitro diagnostic chemical reagents for use on the Cobas MIRA clinical chemistry system. Sensing principle based on standard clinical chemistry enzymatic or colorimetric assays. System is a standalone automated analyzer component. No specific materials or software architecture details provided.
Indications for Use
Indicated for in vitro quantitative determination of various analytes (ALT, Amylase, AST, Direct/Total Bilirubin, Calcium, CO2, Chloride, Cholesterol, Creatinine, Glucose, Iron, Magnesium, Inorganic Phosphorus, Total Protein, Triglycerides, Urea Nitrogen, UIBC, Uric Acid) in human serum, plasma, or urine for diagnosis and treatment of liver, heart, metabolic, renal, and pancreatic diseases.
Regulatory Classification
Identification
An alanine amino transferase (ALT/SGPT) test system is a device intended to measure the activity of the enzyme alanine amino transferase (ALT) (also known as a serum glutamic pyruvic transaminase or SGPT) in serum and plasma. Alanine amino transferase measurements are used in the diagnosis and treatment of certain liver diseases (e.g., viral hepatitis and cirrhosis) and heart diseases.
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird symbol, with three curved lines representing its wings or body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the bird symbol. The text is in all caps and appears to be in a sans-serif font.
Food and Drug Administration 2098 Gaither Road Rockville MD 20850
JAN - 7 199
David Johnston TAI Technical Director TRACE America, Inch 7260 Northwest 58th Street Miami, Florida 33166
Re : K973869 TRACE Reagent Line for the Cobas Mira Regulatory Class: II CKA, JFJ, CDQ, CEK, CGX, CHH, CIG, CIT, Product Code: JGY, JHB, JIY, JMO, KHS Dated: October 24, 1997 Received: October 28, 1997
Dear Mr. Johnston:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major requlations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory In addition, FDA may publish further announcements action. concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic
Product Radiation Control provisions, or other Federal laws or requlations.
{1}------------------------------------------------
Page 2
Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88), this device may require a CLIA complexity categorization. To determine if it does, you should contact the Centers for Disease Control and Prevention (CDC) at (770) 488-7655.
This letter will*allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA deboring of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Steven Butman
Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
se
Intended for the the In Vitro, quantitative determination of ALT (L-Alanine;2-Oxoglutarate Aminotransferase EC2.6.1.2) in human serum on the Cobas MIRA® clinical chemistry system.
This alanine aminotransferase (ALT/SGPT) test system is a device intended to measure the activity of the enzyme alanine aminotransferase (ALT) (also known as a serum glutamic pyruvic transaminase or SGPT) in serum and plasma. Alanine aminotransferase measurements are used in the diagnosis and treatment of certain liver diseases (e.g. viral hepatitus and cirrhosis) and heart diseases. CFR 862.1030
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
AH On Awn
Prescription Use (Per 21 CFR 801.109)
OR
Over-The-Counter Use
{3}------------------------------------------------
510(k) Number (if known): Device Name: _ TRACE REAGENT LINE FOR THE COBAS MIRA Indications for Use:
ﺔ
Intended for the the In Vitro, quantitative determination of KAMYLASE (1,4-%- D glucan glucanohydrolase EC3.2.1.1) in human serum and urine on the Cobas MIRA ® clinical chemistry system.
This Amylase test system is a device intended to measure the activity of the enzyme Amylase in serum and urine . Amylase measurements are used primarily for the diagnosis and treatment of pancreatitis (inflammation of the pancreas) CFR 862.1070
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109)
.
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Division Sign-Off)
Division of Clinical Laboratory Devices
510(k) Number h973869
{4}------------------------------------------------
ા
Intended for the the In Vitro, quantitative determination of AST (Aspartate aminotransferase EC2.6.1.1) in human serum on the Cobas MIRA ® clinical chemistry system.
This "aspartate aminotransferase (AST/SGOT) test system is a device intended to measure the activity of the enzyme aspartate aminotransferase (AST) (also known as a serum glutamic oxaloacetic transferase or SGOT) in serum and plasma. Aspartate aminotransferase measurements are used in the diagnosis and treatment of certain types of liverand heart disease." CFR 862.1100
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE) -----------------
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Optional Format 1-2-96)
310(K) Number: 973869
{5}------------------------------------------------
510(k) Number (if known): K97 3869
Device Name: TRACE REAGENT LINE FOR THE COBAS MIRA Indications for Use:
ﻴﻒ
Intended for the the In Vitro, quantitative determination of Direct Bilirubin in human serum on the Cobas MIRA ® clinical chemistry system.
This "Direct Bilirubin test system is a device intended to measure the levels of bilirubin (direct) in plasma or serum. Measurements of levels of bilirubin, an organic compound formed during the normal and abnormal destruction of red blood cells, if used in the diagnosis and treatment of the liver, hemolytic hematological, and metabolic disorders, including hepatitis and gall bladder block." CFR 862.1110
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
**Prescription Use** √
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
Division Sign-Off)
Division of Clinical Laboratory Devices
510(k) Number. k973869
{6}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Total Bilirubin in human serum on the Cobas MIRA ® clinical chemistry system.
This "Total Bilirubin test system is a device intended to measure the levels of bilirubin (Total) in plasma or serum. Measurements of levels of bilirubin, an organic compound formed during the normal and abnormal destruction of red blood cells, if used in the diagnosis and treatment of the liver, hemolytic hematological, and metabolic disorders, including hepatitis and gall bladder block." CFR 862.1110
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use
(Division Sign-Off)
Division of Clinical Laboratory evices
510(k) Number K973869
{7}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Calcium in human serum or urine on the Cobas MIRA ® clinical chemistry system.
This "Calcium test system is a device intended to measure the total calcium level in serum. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms" CFR 862.1145
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Division Sign-Off)
Divi
510(k) Number: K973869
{8}------------------------------------------------
ﺑ
Intended for the the In Vitro, quantitative determination of Total CO2 in human serum on the Cobas MIRA ® clinical chemistry system.
This " bicarbonatel carbon dioxide test system is a device intended to measure the total bicarbonate/carbon dioxide plasma, serum and whole blood. Bicarbonate/carbon dioxide measurements are used in the diagnosis and treatment of numerous potentially serious disorders associated with changes in body acid base balance. " CFR 862.1160
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
**Prescription Use**
(Per 21 CFR 801.109)
✓
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Division Sign-Off)
Division of Clinical Laboratory Devicer
510(k) Number 973869
{9}------------------------------------------------
u
Intended for the the In Vitro, quantitative determination of Chloride in human serum on the Cobas MIRA ® clinical chemistry system.
This " Chloride test system is a device intended to measure the Chloride in plasma, serum, sweat and urine. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis. " CFR 862.1170
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
**Prescription Use**
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Division Sign-Off)
Divis
510(k) Number
K973869
{10}------------------------------------------------
510(k) Number (if known): __ K97 3869
Device Name: TRACE REAGENT LINE FOR THE COBAS MIRA Indications for Use:
Intended for the the In Vitro, quantitative determination of Cholesterol in human serum on the Cobas MIRA ® clinical chemistry system.
This " Cholesterol test system is a device intended to measure the Cholesterol in plasma and serum. Cholesterol measurements are used in the diagnosis and treatment of disorders involving excess cholesterol in the blood and lipid and lipoprotein metabolism disorders. " CFR 862.1175
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation-(ODE) ------------------
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
Sigf
(Optional Format 1-2-96)
vion of Clinical Laboratory Devices
510(k) Number. K973869
{11}------------------------------------------------
se
Intended for the In Vitro, quantitative determination of Creatinine in human serum and urine on the Cobas MIRA ® clinical chemistry system.
This " Creatinine test system is a device intended to measure the Creatinine levels in plasma and urine. Creatinine measurements are used in the diagnosis and treatment of renal diseases,in monitoring renal dialysis, and a calculation basis for measuring other urine analytes. " CFR 862.1225
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
OR Over-The-Counter Use__
(Optional Format 1-2-96)
973869
OF
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
{12}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Glucose in human serum and urine on the Cobas MIRA ® clinical chemistry system.
This " Glucose test system is a device intended to measure the Glucose levels in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus,neonatal hypoglycemia , idiopathic hypoglycemia and pancreatic islet cell carcinoma. " CFR 862.1360
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE) -----------------------------------------------------------------------------------------------------------------------
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
Division Sign-Circa ivision ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 510(k) Number
{13}------------------------------------------------
u
Intended for the the In Vitro, quantitative determination of Iron in human serum on the Cobas MIRA ® clinical chemistry system.
This " Iron (non-heme) test system is a device intended to measure Iron (non-heme)in serum and plasma. Iron (non-heme) measurements are used in the diagnosis and treatment of diseases such as iron deficiency anemia , hemochromatosis ( a disease associated with widespread deposit in the tissues of two iron containing pigments, hemosiderin and hemofuscin, and characterized by pigmentation of the skin) and chronic renal disease. " CFR 862.1410
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
| Prescription Use | |
|----------------------|--|
| (Per 21 CFR 801.109) | |
OR
| (Division Sign- | |
|-----------------|---------|
| Division of C. | |
| 510(k) Number | K923869 |
| Over-The-Counter Use | |
|--------------------------|--|
| (Optional Format 1-2-96) | |
{14}------------------------------------------------
u
Intended for the In Vitro, quantitative determination of Magnesium in human serum and urine on the Cobas MIRA ® clinical chemistry system.
This " Magnesium test system is a device intended to measure magnesium levels in serum and plasma. Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low plasma levels of magnesium) and hypermagnasemia (abnormally high levels of magnesium). " CFR 862.1495
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Option
(Division
Division
510(k) Num... k973869
(Optional Format 1-2-96)
{15}------------------------------------------------
Page 1 of of _________________________________________________________________________________________________________________________________________________________________
510(k) Number (if known): __ K97 3869 Device Name: TRACE REAGENT LINE FOR THE COBAS MIRA Indications for Use:
Intended for the the In Vitro, quantitative determination of Inorganic Phosphorus in human serum or urine on the Cobas MIRA ® clinical chemistry system.
This " Phosphorus (inorganic) test system is a device intended to measure inorganic phosphorus in serum, plasma and urine. Measurements of phosphorus (inorganic) are used in the diagnosis and treatment of various disorders, including parathyroid gland and kidney diseases , and vitamin D imbalance. " CFR 862.1580
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use
Image /page/15/Picture/10 description: The image shows a document with the text "Division Sign-Off", "Division of Clinical Laboratory Devices", and "510(k) Number". The number "K973864" is also visible on the document. The text is slightly blurred and appears to be handwritten or stamped onto the document.
{16}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Total Protein in human serum on the Cobas MIRA ® clinical chemistry system.
This " Total Protein test system is a device intended to measure Total protein(s) in serum or plasma. Measurements obtained by this device are used in the diagnosis and treatment of a variety of diseases involving the liver, kidney or bone marrow as well as other metabolic or nutritional disorders " CFR 862. 1635
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use _-(Per 21 CFR 801.109)
Over-The-Counter Use (Optional Format 1-2-96)
OR
{17}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Triglycerides in human serum on the Cobas MIRA ® clinical chemistry system.
This " Triglyceride test system is a device intended to measure Triglyceride (neutral fat) in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of patients with diabetes mellitus, nephrosis, liver obstruction, other diseases involving lipid metabolism, or various endocrine disorders. " CFR 862.1705
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
(Division Sign-Off)
Division of Clinical Laboratory Services
510(k) Number: 9723869
{18}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Urea Nitrogen in human serum or urine on the Cobas MIRA ® clinical chemistry system.
This " urea nitrogen test system is a device intended to measure urea nitrogen (an end product of nitrogen metabolism) in whole blood, serum or plasma. Measurements obtained by this device are used in the diagnosis and treatment of certain renal and metabolic diseases. " CFR 862.1770
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109) ✓
(Per 21 CFR 801.109)
OR
Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________
Image /page/18/Picture/11 description: The image shows a document with the text "(Division Sign-Off) Division of Clinical Laboratory Devices 510(k) Number." written on it. There is a signature over the text, and the number "42973869" is written below the text. The text and signature are slightly tilted.
{19}------------------------------------------------
Intended for the the In Vitro, quantitative determination of Unbound Iron-Binding Capacity (UIBC) in human serum on the Cobas MIRA ® clinical chemistry system.
This " Iron-binding capacity test system is a device intended to measure Iron-binding capacity in serum. Iron-binding capacity measurements are used in the diagnosis and treatment of anemia. " CFR 862.1415
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
(Per 21 CFR 801.109)
OR
Over-The-Counter Use
Image /page/19/Picture/10 description: The image shows a document with the text "(Division Sign-Off) Division of Clinical Labora 510(k) Number" followed by the number 2973869. The text is slightly slanted and partially obscured by a signature. The document appears to be a form or record related to clinical laboratory divisions.
{20}------------------------------------------------
510(k) Number (if known):
Device Name: TRACE REAGENT LINE FOR THE COBAS MIRA Indications for Use:
Intended for the the In Vitro, quantitative determination of Uric Acid in human serum or urine on the Cobas MIRA ® clinical chemistry system.
This " Uric Acid test system is a device intended to measure uric acid in serum, plasma or urine. Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs. " CFR 862.1775
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
**Prescription Use**
(Per 21 CFR 801.109)
OR Over-The-Counter Use
(Optional Format 1-2-96)
Division of Clinical Laboratory Devices
510(k) Number
K973869
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.