K973476 · Eastman Kodak Company · EHD · Nov 10, 1997 · Dental
Device Facts
Record ID
K973476
Device Name
KODAK DIGITAL SCIENCE-DENTAL IMAGE VIEWER
Applicant
Eastman Kodak Company
Product Code
EHD · Dental
Decision Date
Nov 10, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.1800
Device Class
Class 2
Attributes
Software as a Medical Device
Indications for Use
Intended uses in the dental industry include the following: Radiograph viewing and manipulation for insurance claims adjudication. Radiograph viewing and manipulation for diagnostic purposes. Radiograph viewing for patient education and consultation. When used for diagnostic purposes, the patient population will be the general public, and the diseases/conditions that the device will be used to diagnose are; dental caries, periodontal disease and bone loss, tooth fractures, jaw misalignment, and other diseases and conditions that are encountered by general practitioners and specialists in the dental care field.
Device Story
Software package for PC-compatible computers; enables display and manipulation of digitized dental x-ray images. Inputs: digitized dental radiographic film images. Processing: software-based image enhancement tools including rotation, zoom, flip, contrast, and brightness adjustment. Outputs: high-resolution images displayed on monitor for diagnostic review, insurance adjudication, and patient consultation. Used in dental clinics by general practitioners and specialists. Healthcare providers use output to visualize dental conditions; facilitates clinical decision-making regarding treatment planning and diagnosis. Benefits include improved image visualization and efficient practice management integration.
Clinical Evidence
No clinical data. Bench testing only.
Technological Characteristics
Software-based image viewer for PC-compatible computers (Pentium processor, 32MB RAM, Windows 95). Features high-resolution display (800x600, 24-bit color), image manipulation tools (rotate, zoom, flip, contrast, brightness), and monitor calibration. Interfaces with practice management systems. Standalone software application.
Indications for Use
Indicated for viewing and manipulation of dental radiographic film for insurance adjudication, diagnostic purposes, and patient education/consultation. Patient population: general public. Used by dental practitioners to diagnose dental caries, periodontal disease, bone loss, tooth fractures, and jaw misalignment.
Regulatory Classification
Identification
An extraoral source x-ray system is an AC-powered device that produces x-rays and is intended for dental radiographic examination and diagnosis of diseases of the teeth, jaw, and oral structures. The x-ray source (a tube) is located outside the mouth. This generic type of device may include patient and equipment supports and component parts.
{0}------------------------------------------------
NOV 1 1 1) 1697
. )
# 510(k) SUMMARY OF SAFETY AND EFFECTIVE NESS
#### I. Date Prepared:
September 12, 1997
## ll. Submitter:
Eastman Kodak Company Health Imaging Division Dental Business unit 343 State Street Rochester, New York 14650
## III. Contact Person:
Judith A. Wallace Regulatory Affairs (716) 724-2314
#### IV. Device Name:
Kodak Digital Science Dental Image Viewer Trade Name
Dental x-ray image enhancement system Common Name
## V. Device Classification:
FDA has classified the predicate device as Regulatory Class II under CFR 892.1750
## VI. Predicate Device:
TAU Corporation TigerScan/TigerView -- 510(k) No. K955237
## VII. Description of Device:
The KODAK DIGITAL SCIENCE™ Dental Image Viewer is a software package designed to provide full resolution digitized images of a dental x-ray film for diagnostic review, insurance adjudication and patient consultation. The KODAK DIGITAL SCIENCE™ Dental Image Viewer is designed to operate on a standard PC-compatible computer.
KODAK DIGITAL SCIENCE™ Dental Image Viewer features the display of full-mouth sets and other mounts, high-resolution image display and manipulation, and interfaces with practice management systems.
{1}------------------------------------------------
# VIII. Indications for Use:
Intended uses in the dental industry include the following:
- Radiograph viewing and manipulation for insurance claims adjudication. .
- Radiograph viewing and manipulation for diagnostic purposes ●
- Radiograph viewing for patient education and consultation. .
When used for diagnostic purposes, the patient population will be the general public, and the diseases/conditions that the device will be used to diagnose are; dental caries, periodontal disease and bone loss, tooth fractures, jaw misalignment, and other diseases and conditions that are encountered by general practitioners and specialists in the dental care field.
# IX. Substantial Equivalence:
The purpose and functionality of the KODAK DIGITAL SCIENCE™ Dental Image Viewer is substantially similar to the TAU Corporation TigerView system (K955237), as well as numerous other x-ray viewers currently on the market. The basis for the equivalence is that both systems consist of software which will enhance images for diagnosis. The following table summarizes the two products functional equivalence
| Description | Kodak Dental Image<br>Viewer | TAU TigerView |
|---------------------------------------|----------------------------------------------|-------------------------------------------------------------|
| Host Platform: | Pentium Processor based<br>Personal Computer | IBM - Compatible<br>Computer |
| Operating System: | Windows 95 | Windows 3.1. Windows for<br>Workgroups 3.11 or<br>Window 95 |
| Host RAM: | 32 MB | 16 MB |
| Host Magnetic Storage: | 10 MB | at least 400 MB |
| Host Floppy Drives: | 3.5 inches | 3.5 inches |
| Host Processor Speed: | Any Pentium speed | 486 66Mhz or better CPU |
| Host Monitor Size: | 15" diagonal minimum | |
| Display resolution | 800 X 600 at 24 bit color<br>minimum | 800 X 600 |
| Open Case Preview: | No | Yes |
| User Display Preferences: | Yes | No |
| Receive Images from other<br>Systems: | Yes | Yes |
{2}------------------------------------------------
| Description | Kodak Dental Image<br>Viewer | TAU TigerView |
|--------------------------------------|---------------------------------------------|----------------------------------------------------------------|
| Patient List Transmission<br>Status: | No | Receiving status is<br>displayed. |
| Image Manipulation: | Rotate, Zoom, Flip,<br>Contrast, Brightness | Rotate, Zoom, Flip,<br>Contrast, Brightness,<br>Negative Image |
| Monitor Calibration: | Yes | |
KODAK DIGITAL SCIENCE - Dental Image Viewer 510(k) Submission
{3}------------------------------------------------
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
NOV 100 1997
Judith A. Wallace Regulatory Affairs Associate Eastman Kodak Company Health Imaging Division, Dental Business 343 State Street Rochester, NY 14650-1122
Re: K973476
Kodak Digital Science - Dental Image Viewer Dated: September 12, 1997 Received: September 15, 1997 Regulatory class: II 21 CFR 872.1800/Procode: 90 EHD
Dear Ms. Wallace:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic OS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for question and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours.
hJliau Yu
Lillian Yin, Ph.D.
Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
510(K) Number (if known):
Device Name: KODAK DIGITAL SCIENCE - Dental Image Viewer Indication of use: Viewing of dental radiographic film
Concurrence of CDRH, Office of Device Evaluation
| Prescription Use (Per 21 CFR 801.109) | <div> <span style="text-decoration: underline;">✓</span> </div> |
|---------------------------------------|-----------------------------------------------------------------|
| | OR |
| Over-The-Counter | <span style="text-decoration: underline;">____</span> |
KODAK DIGITAL SCIENCE - Dental Image Viewer
510(k) Submission
| (Division Sign-Off) | <div> <img alt="Signature" src="signature.png"/> </div> |
|--------------------------------------------------------------------|---------------------------------------------------------|
| | 9/12/97 |
| Division of Reproductive, Abdominal, ENT, and Radiological Devices | |
| 510(k) Number | K973476 |
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.