K973412 · Sulzer Orthopedics, Inc. · JWH · Dec 8, 1997 · Orthopedic
Device Facts
Record ID
K973412
Device Name
NATURAL-KNEE II CONSTRAINED KNEE SYSTEM
Applicant
Sulzer Orthopedics, Inc.
Product Code
JWH · Orthopedic
Decision Date
Dec 8, 1997
Decision
SN
Submission Type
Traditional
Regulation
21 CFR 888.3560
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Natural-Knee™ II Constrained Knee System is intended use in the following diagnostic indications : - 1) Patient conditions, including but not limited to, inflammatory degenerative joint disease (e.g., rheumatoid arthritis) and noninflammatory degenerative joint disease (e.g., osteoarthritis, avascular necrosis). - 2) Correctable valgus-varus deformity and moderate flexion contracture. - 3) Those patients with failed previous surgery where pain, deformity, or dysfunction persist. - 4) Revision of previously failed knee arthroplasty. The Natural-Knee™ II Constrained Knee System is intended only for use with bone cement in the United States. Uncemented use of the Natural-Knee™ II Constrained Knee System is considered to be investigational in the United States. This device is intended for single use only.
Device Story
Non-porous total knee replacement system; semiconstrained design; used for primary and revision knee surgeries. Components: CoCr femoral component (anatomic/asymmetrical), Ti-4A1-6V tibial baseplate, UHMWPe tibial insert. Includes CoCr pin for posterior stability; compatible with revision stems, femoral/tibial spacers, and patellar components. Used by orthopedic surgeons in clinical settings. Device replaces knee joint surfaces; provides stability in absence of posterior cruciate ligament; requires intact collateral ligaments. Fixed to bone using acrylic bone cement. Benefits: restores joint function, reduces pain, corrects deformity in patients with failed prior arthroplasty or degenerative disease.
Indicated for patients with inflammatory or non-inflammatory degenerative joint disease (e.g., rheumatoid arthritis, osteoarthritis, avascular necrosis), correctable valgus-varus deformity, moderate flexion contracture, or failed previous knee surgery/arthroplasty requiring revision. Requires intact medial and lateral collateral ligaments; posterior cruciate ligament must be absent, deficient, or removed. Intended for cemented use only.
Regulatory Classification
Identification
A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).
Predicate Devices
Natural-Knee II System (Sulzer Orthopedics)
Maxim Constrained Knee (Biomet)
Coordinate Revision Knee (DePuy)
Reference Devices
Natural-Knee II All-Poly Patella I
Natural-Knee II Metal-Backed Patella
Natural-Knee II Revision Stems
Natural-Knee II Tibial Spacers I
Natural-Knee II Revision Tibial Stems
Submission Summary (Full Text)
{0}------------------------------------------------
K97 3412
DEC - 8 1997
## 510(k) SUMMARY
In accordance with the Food and Drug Administration Rule to implement provisions of the Safe Medical Devices Act of 1990 and in conformance with 21 CFR 807, this is to serve as a Summary of Safety and Effectiveness for the Natural-Knee™ II Constrained Knee System.
| Submitter: | Sulzer Orthopedics Inc.<br>9900 Spectrum Drive<br>Austin, Texas 78717<br>(512) 432-9900 |
|-------------------------|--------------------------------------------------------------------------------------------------------------|
| Date: | July 18, 1997 |
| Contact Person: | Jacquelyn Hughes<br>Manager, Regulatory Affairs |
| Classification Name: | Prosthesis, knee, patellofemorotibial, semi-constrained,<br>cemented, polymer/ metal/polymer 21 CFR 888.3560 |
| Common/Usual Name: | Knee Prosthesis, Partially Constrained |
| Trade/Proprietary Name: | The Natural-Knee™ II Constrained Knee System |
#### PRODUCT DESCRIPTION
The Natural-Knee™ II Constrained Knee System is a non-porous total knee replacement intended for primary and revision knee surgeries. The components are intended for resurfacing of the knee joint where the posterior cruciate ligament is absent, deficient, or has been removed at the time of surgery. The system is a semiconstrained design and both medial and lateral collateral ligaments must be intact.
The Natural-Knee II Constrained Knee femoral component is manufactured from cobalt chromium/molybdenum (CoCr) alloy and is anatomic and asymmetrical in design. The Natural-Knee II Revision Stems may be used with the Natural-Knee II Constrained Knee System femoral component. Femoral spacers manufactured from CoCr alloy are also available for use with the Natural-Knee II Constrained Knee femoral component. A revision adapter spacer, also manufactured from CoCr, converts the internal box geometry of the Natural-Knee II Constrained Knee femoral component to match that of the Natural-Knee II Revision femoral component. The Natural-Knee II Revision Femoral Spacers may be added to the revision adapter spacer if additional augmentation is necessary.
The Natural-Knee II Constrained Knee tibial components include a baseplate and polyethylene insert. The tibial components are also anatomic and asymmetrical in design. The tibial baseplate is manufactured from Titanium alloy (Ti-4A1-6V). The baseplate is designed to be used with the Natural-Knee II Revision Tibial Spacers. The Natural-Knee II Constrained Knee tibial baseplate may be used with the Natural-Knee II Revision Tibial The tibial inserts are manufactured from Ultra High Molecular Weight Stems. Polyethylene (UHMWPe). A CoCr pin passing vertically from the posterior stabilizing eminence of the tibial insert to the tibial baseplate provides additional stability.
The Natural-Knee II Constrained Knee System is to be used with the Natural-Knee II metalbacked and all-poly patellar components.
{1}------------------------------------------------
This device is intended for use with the following previously cleared devices:
- Natural-Knee II All-Poly Patella I
- Natural-Knee II Metal-Backed Patella
- Natural-Knee II Revision Stems
- Natural-Knee II Tibial Spacers I
- Natural-Knee II Revision Tibial Stems
The Natural-Knee II Constrained Knee Tibial Baseplate may also be used with existing Natural-Knee II tibial inserts. The existing Natural-Knee II tibial inserts are not compatible with the Natural-Knee II Constrained Knee Femoral Component.
### SPECIFIC DIAGNOSTIC INDICATIONS
The Natural-Knee II Constrained Knee System is intended use in the following diagnostic indications :
- 1) Patient conditions, including but not limited to, inflammatory degenerative joint disease (e.g., rheumatoid arthritis) and noninflammatory degenerative joint disease (e.g., osteoarthritis, avascular necrosis).
- 2) Correctable valgus-varus deformity and moderate flexion contracture.
- 3) Those patients with failed previous surgery where pain, deformity, or dysfunction persist.
- 4) Revision of previously failed knee arthroplasty.
The Natural-Knee II Constrained Knee System is intended only for use with bone cement in the United States. Uncemented use of the Natural-Knee II Constrained Knee System is considered to be investigational in the United States. This device is intended for single use only.
#### SUBSTANTIAL EQUIVALENCE
The Natural-Knee II Constrained Knee System is substantially equivalent to the Natural-Knee II System (Sulzer Orthopedics), the Maxim Constrained Knee (Biomet), and the Coordinate Revision Knee (DePuy).
{2}------------------------------------------------
Image /page/2/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle with three human profiles incorporated into its body.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
## DEC - 8 1997
Ms. Jacquelyn Hughes Manager, Regulatory Affairs Sulzer Orthopedics, Inc. 9900 Spectrum Drive Austin, Texas 78717
Re : K973412 The Natural-Knee II Constrained Knee System Requlatory Class: II Product Code: JWH Dated: September 8, 1997 September 9, 1997 Received:
Dear Ms. Hughes:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). This decision is based on this device being equivalent only to similar devices labeled and intended to be fixed within bone with acrylic "bone cement." You may, therefore, market your device subject to the general controls provisions of the Act and the following limitations:
- The thinnest tibial insert available is the nominal "9mm" 1. sized insert, which has a minimum polyethylene thickness under the condyles of 6.00mm.
- This device may not be labeled or promoted for non-2. cemented use.
- 3 . All labeling for this device, including package label and labeling included within the package, must prominently state that the device is intended for cemented use only.
{3}------------------------------------------------
Page 2 - Ms. Jacquelyn Hughes
- Any non-cemented fixation of this device is considered 4. investigational and may only be investigated as a significant risk device in accordance with the investigational device exemption (IDE) regulation under 21 CFR, Part 812. All users of the device for noncemented fixation must receive approval from their respective institutional review boards (IRBs) and the Food and Druq Administration (FDA) to conduct the investigation.
The general controls provisions of the Act include requirements for annual reqistration, listing of devices, good manufacturing practices, labeling, and prohibitions against misbranding and adulteration.
If vour device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP requlation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Reqister. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal Laws or Requlations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification immediately. An FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be
{4}------------------------------------------------
Page 3 - Ms. Jacquelyn Hughes
obtained from the Division of Small Manufacturers Assistance obtained from the Division of Small Mark (300) 443-6597 or at
at its toll-free number (800) 638-2041 or addon'demain html" at its toll-free number (600) 650 2041 Of (600) 600 - 1000
its Internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Witten, Ph.D., M.D.
Director
Division of General and
Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
510(k) Number (if known):_____________________________________________________________________________________________________________________________________________________
Device Name: Natural-Knee™ II Constrained Knee System
# Indications For Use:
The Natural-Knee™ II Constrained Knee System is intended use in the following diagnostic indications:
- Patient conditions, including but not limited to, inflammatory degenerative joint 1. disease (e.g., rheumatoid arthritis) and noninflammatory degenerative joint disease (e.g., osteoarthritis, avascular necrosis).
- 2. Correctable valgus-varus deformity and moderate flexion contracture.
- Those patients with failed previous surgery where pain, deformity, or 3. dysfunction persist.
- 4. Revision of previously failed knee arthroplasty.
The Natural-Knee™ II Constrained Knee System is intended only for use with bone cement. Uncemented use of the Natural-Knee™ II Constrained Knee System is considered to be investigational in the United States.
### (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
t
(Division Sign-Off) Division of General Restorative Devices
510(k) Number.
OR
Prescription Use
**Over-The-Counter Use**
(Optional Format 1-2-96)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.