STERI-OSS 3.25 MM REPLACE DENTAL IMPLANT SYSTEM
Device Facts
| Record ID | K973402 |
|---|---|
| Device Name | STERI-OSS 3.25 MM REPLACE DENTAL IMPLANT SYSTEM |
| Applicant | Steri-Oss, Inc. |
| Product Code | DZE · Dental |
| Decision Date | Nov 26, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The intended use for this device system is to serve as support for prosthetic devices to restore patient chewing functions.
Device Story
System comprises 3.25 mm diameter endosseous dental implants, healing screws, healing abutments, and abutments. Implants serve as artificial tooth roots; abutments/prostheses serve as crowns. Healing components protect internal threads and expand gingival tissue during healing. Used by dental professionals to restore masticatory function. Titanium alloy construction; tapered, threaded design with superior external hex. Components are anodized magenta. No clinical data provided.
Clinical Evidence
No clinical data. Bench testing only.
Technological Characteristics
Titanium alloy endosseous dental implants; 3.25 mm diameter; 10-16 mm length. Tapered, threaded design with superior external hex. Surface anodized magenta. Sterile.
Indications for Use
Indicated for patients requiring prosthetic support to restore chewing function via endosseous dental implants.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Predicate Devices
- Steri-Oss Replace Implants, Healing Screws, Healing Abutments, and Abutments (K964220)
- Steri-Oss (3.25 mm diameter) Titanium Plasma Sprayed Cylindrical Implant (K911592)