FINALLY FREE

K972695 · Mehl/Group Marketing · KCX · Oct 22, 1997 · General, Plastic Surgery

Device Facts

Record IDK972695
Device NameFINALLY FREE
ApplicantMehl/Group Marketing
Product CodeKCX · General, Plastic Surgery
Decision DateOct 22, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.5360
Device ClassClass 1
AttributesTherapeutic

Indications for Use

The FINALLY FREE Ultra tweezer-type epilator is indicated for the removal of unwanted body and facial hair. Like the predicated in the is specifically designed for use by consumers.

Device Story

Finally Free Ultra is a consumer-use, tweezer-type epilator for body and facial hair removal. Device utilizes 'NU-Trolysis' process: radio frequency (RF) energy applied to hair shaft via tweezer-wand; energy conducts to hair root, causing separation from follicle and stunting growth. System consists of plastic-encased base unit and hand-held wand; plugs into standard 110V wall socket. Base unit contains crystal oscillating component and amplifying/filtering circuitry to convert AC current to RF energy. User grasps individual hair with tweezer; power select knob allows adjustment. Device intended for home use by consumers.

Clinical Evidence

No clinical data. Substantial equivalence is based on bench testing comparing RF energy output (frequency and voltage) between the subject device and the predicate.

Technological Characteristics

Plastic-encased unit; 110V AC power source. Sensing/actuation: crystal oscillating component and amplifying/filtering circuitry to generate RF energy (27.100 - 27.322 MHz). Hand-held wand with tweezer applicator. Includes power select knob. No software or digital connectivity.

Indications for Use

Indicated for the removal of unwanted body and facial hair in consumers.

Regulatory Classification

Identification

The tweezer-type epilator is an electrical device intended to remove hair. The energy provided at the tip of the tweezer used to remove hair may be radio frequency, galvanic (direct current), or a combination of radio frequency and galvanic energy.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the date October 22, 1997. The month is abbreviated to OCT. The numbers are written in a simple, sans-serif font. The text is black on a white background. Image /page/0/Picture/1 description: The image shows a logo with a black circle on the left side. The circle has some white dots inside. To the right of the circle, the text "EHL / Group Marketing Consumer Products Division" is displayed in a stylized font. K972695 510(k) SUMMARY ## FINALLY FREE ULTRA Finally Free Ultra is a tweezer-type epilator for the removal of unwanted body and facial hair. It is designed for consumer home use. Reviewed by the General and Plastic Surgery Device Classification Panel, tweezer-type epilators are assigned the Product Code KCX and are regulated under 21 CFR 878.5360. Tweezer-type epilators are Class III devices, although FDA has proposed reclassifying them into Class I. The device removes hair by the application of radio frequency energy to the hair shaft, which in turn conducts it to the hair root. There the energy causes the root to separate from follicle, thereby causing the hair to fall out. Further damage to the surrounding tissue stunts hair growth. This patented process is called NU-Trolysis. Finally Free Ultra is substantially equivalent to Forever Free, another consumer-use tweezertype epilator manufactured by Burke/Neutech (K952117). Both are plastic encased units which plug into a standard 110V wall socket and which convert the AC current into radio frequency energy by means of a crystal oscillating component and both amplifying and filtering circuitry. The energy is delivered by a line cord attached to a hand-held wand with a tweezer which grasps the individual hair. Energy outputs for the two devices were measured as follows: | | FINALLY FREE<br>(6 Units) | FOREVER FREE<br>(2 Units) | |-----------------|---------------------------|---------------------------| | Frequency (MHZ) | 27.100 - 27.322 | 27.064 - 27.112 | | Voltage (p-p) | 39.2 - 59.4 | 30.1 - 31.2 | The two devices differ slightly in that much of Finally Free's essential electronic components are contained within the base unit whereas for Forever Free most components are found within the wand. Also, a power select knob is provided with Finally Free, but not for Forever Free. Thomas Blake, R.Ph. 7/16/97 Date 221 Boston Post Road East · Marlboro, MA 01752 · 508-481-9495 · Fax: 508-460-9541 {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the United States Department of Health and Human Services. The logo features a stylized eagle head with three stripes extending from the back of the head, representing the department's mission to promote health, well-being, and human services. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the eagle head. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20856 Thomas Blake, R. Ph. MEHL/Group Marketing 48 Mt. Olive Road Budd Lake, New Jersey 07828 OCT 22 1997 Re: K972695 Trade Name: Finally Free ULTRA Regulatory Class: III Product Code: KCX Dated: July 17, 1997 Received: July 18, 1997 Dear Dr. Blake: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements , as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (OS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition. FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {2}------------------------------------------------ Page 2 - Thomas Blake, R. Ph. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Mark n Miller Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ 510(k) Number (if known) _ K972695 Device Name: EINALLY FREE ULTRA_______________________________________________________________________________________________________________________________________________ Indications for Use: The FINALLY FREE Ultra tweezer-type epilator is indicated for the removal of unwanted body and facial hair. Like the predicated in the is specifically dosigned for use h is specifically designed for use by consumers. (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) ![Signature](signature.jpg) | (Division Sign-Off) | | |-----------------------------------------|---------| | Division of General Restorative Devices | | | 510(k) Number | K972695 | | Prescription Use (Per 21 CFR 801.109) | X | |---------------------------------------|---| |---------------------------------------|---| OR | Over-The-Counter Use (Optional Format 1-2-96) | X | |-----------------------------------------------|---| |-----------------------------------------------|---|
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...