← Product Code [LPL](/productcode/LPL) · K971515

# PROMED 38 SOFBLU (POLYMACON) SOFT (SPHERICAL & TORIC) DAILY WEAR CONTACT LENS (TINTED, LATHE-CUT FORM LENS BLANK) (K971515)

_Biomed Devices Corp. · LPL · May 20, 1997 · Ophthalmic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K971515

## Device Facts

- **Applicant:** Biomed Devices Corp.
- **Product Code:** [LPL](/productcode/LPL.md)
- **Decision Date:** May 20, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 886.5925
- **Device Class:** Class 2
- **Review Panel:** Ophthalmic

## Indications for Use

The PROMED 38 SOFBLU (Toric) (polymacon) SOFT CONTACT LENSES for daily wear are indicated for the correction of visual acuity in not aphakic persons with non-diseased eyes with myopia or hyperopia and refractive astigmatism not exceeding 10 Diopters. The PROMED 38 SOFBLU (Spherical) (polymacon) SOFT CONTACT LENSES for daily wear are indicated for the correction of visual acuity in aphakic and not aphakic persons with non-diseased eyes with myopia or hyperopia. The lens may be worn by persons who exhibit reffactive astigmatism of 1.50 diopters or less where the astigmatism does not interfere with visual acuity.

## Device Story

PROMED 38 SOFBLU is a soft contact lens manufactured from polymacon. Available in spherical and toric designs, lenses are lathe-cut from lens blanks and feature a visibility tint. Intended for daily wear to correct visual acuity in patients with myopia, hyperopia, and astigmatism. Prescribed by eye care professionals for use in non-diseased eyes. Lenses function by modifying light refraction to improve vision. No electronic components or software involved.

## Clinical Evidence

No clinical data provided; substantial equivalence determined via 510(k) regulatory pathway.

## Technological Characteristics

Material: Polymacon (hydrophilic polymer). Form factor: Soft contact lens (spherical and toric). Manufacturing: Lathe-cut from lens blanks. Features: Visibility tinted. Energy source: None. Connectivity: None. Sterilization: Not specified.

## Regulatory Identification

A soft (hydrophilic) contact lens is a device intended to be worn directly against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as a therapeutic bandage. The device is made of various polymer materials the main polymer molecules of which absorb or attract a certain volume (percentage) of water.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with its wings spread, and the words "SERVICES - USA" are written above the eagle. The words "DEPARTMENT OF HEALTH & HUM" are written on the left side of the logo.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

## MAY 2 0 1997

Mr. Martin Dalsing Consultant for Biomed Devices Corporation 623 Glacier Drive Grand Junction, CO 81503 · · ·

Re: K971515

Trade Name: PROMED 38 SOFBLU (POLYMACON) Soft (Spherical and Toric) Daily Wear Contact Lens (Visibility Tinted, Lathe-cut from Lens Blank)

Regulatory Class: II Product Code: 86 LPL Dated: April 23, 1997 Received: April 25, 1997

Dear Mr. Dalsing:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21-CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may sublish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

{1}------------------------------------------------

Page 2 - Mr. Martin Dalsing

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permics your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597.

Sincerely yours,
Alberl Rosenthal

A. Ralph Rosenthal, M.D. Director Division of Ophthalmic Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

BIOMED DEVICES CORPORATION 510(K) Premarket Noufication

## INDICATIONS FOR USE STATEMENT

Device Name:

Promed 38 SOFBLU (polymacon) Soft (Spherical & Toric) Daily Wear Contact Lens

INDICATIONS FOR USE:

The PROMED 38 SOFBLU (Toric) (polymacon) SOFT CONTACT LENSES for daily wear are indicated for the correction of visual acuity in not aphakic persons with non-diseased eyes with myopia or hyperopia and refractive astigmatism not exceeding 10 Diopters.

The PROMED 38 SOFBLU (Spherical) (polymacon) SOFT CONTACT LENSES for daily wear are indicated for the correction of visual acuity in aphakic and not aphakic persons with non-diseased eyes with myopia or hyperopia. The lens may be worn by persons who exhibit reffactive astigmatism of 1.50 diopters or less where the astigmatism does not interfere with visual acuity.

## (PLEASE DO OT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Vickie W.L. Winston
(Division Sign-Off)
Division of Ophthalmic Devices

Prescription Use V (Per 21 CFR 801.109)

Division of Ophthalmic Devices
510(k) Number K971515

Over-The-Counter Use

(Optional Format 1-2-96)

PROMED 38 SOFBLU (Polyment) Soft (Spherical & Torio) Delly Wear Contact Lanz (Tistod, Lather-QF Even Land Bluel)

Page - 12

---

**Source:** [https://fda-staging.innolitics.com/device/K971515](https://fda-staging.innolitics.com/device/K971515)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
