TRANSEND EX PLATINUM GUIDEWIRE

K971254 · Boston Scientific Corp · DQX · Jul 1, 1997 · Cardiovascular

Device Facts

Record IDK971254
Device NameTRANSEND EX PLATINUM GUIDEWIRE
ApplicantBoston Scientific Corp
Product CodeDQX · Cardiovascular
Decision DateJul 1, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1330
Device ClassClass 2

Indications for Use

The Transend EX Platinum Guidewire is intended for general intravascular use, including the neuro and peripheral vasculature. The wire can be torqued to facilitate the selective placement of diagnostic or therapeutic catheters. This device is not intended for use in coronary arteries. A torque device (pin vise) is included with the wire to facilitate directional manipulation of the guidewire. A guidewire introducer is included with each wire to facilitate the introduction of the guidewire into catheter hubs or hemostatic valves.

Device Story

Transend EX Platinum Guidewire is a steerable intravascular guidewire; used to facilitate selective placement of diagnostic or therapeutic catheters in neuro and peripheral vasculature. Device includes a torque device (pin vise) for directional manipulation and a guidewire introducer for insertion into catheter hubs or hemostatic valves. Operated by clinicians in clinical settings. Device is provided sterile for single-procedure use. Performance relies on mechanical properties including tip flexibility, torque strength, and torque response; hydrophilic coating enhances lubricity. Output is the physical guidance of catheters through the vasculature to a target site, aiding clinical navigation during interventional procedures.

Clinical Evidence

Bench testing only. Evaluations included tip tensile strength, tip flexibility, torque strength, torque response, coating adherence, coating extraction, lubricity testing, biocompatibility, and in vivo testing.

Technological Characteristics

Intravascular guidewire with hydrophilic coating. Includes torque device and introducer. Mechanical characteristics: tip tensile strength, tip flexibility, torque strength, torque response. Sterile, single-use. No software or electronic components.

Indications for Use

Indicated for general intravascular use in neuro and peripheral vasculature to facilitate selective placement of diagnostic or therapeutic catheters. Contraindicated for use in coronary arteries.

Regulatory Classification

Identification

A catheter guide wire is a coiled wire that is designed to fit inside a percutaneous catheter for the purpose of directing the catheter through a blood vessel.

Special Controls

*Classification.* Class II (special controls). The device, when it is a torque device that is manually operated, non-patient contacting, and intended to manipulate non-cerebral vascular guide wires, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.

Predicate Devices

Submission Summary (Full Text)

{0} K971254 510(k) Premarket Notification BSC Transend EX Platinum Guidewire April 2, 1997 JUL - 1 1997 # ATTACHMENT K # SUMMARY OF SAFETY AND EFFECTIVENESS 000087 {1} 000088 # ATTACHMENT K ## SUMMARY OF SAFETY AND EFFECTIVENESS Pursuant to §513(i)(3)(A) of the Food, Drug, and Cosmetic Act, Boston Scientific Corporation is required to submit with this Premarket Notification either an "...adequate summary of any information respecting safety and effectiveness or state that such information will be made available upon request of any person." Boston Scientific Corporation choose to submit a summary of information respecting safety and effectiveness. According to §513(i)(3)(B), "Any summary under subparagraph (A) respecting a device shall contain detailed information regarding data concerning adverse health effects..." The summary regarding the adverse health effects of the proposed Transend EX Platinum Guidewire is as follows: | Trade Name: | Transend EX Platinum Guidewire | | --- | --- | | Manufacturer: | BSC/SciMed Life Systems, Inc. 2010 E. Center Circle Maplegrove, MN 55441 | | Device Generic Name: | Guidewire | | Classification: | According to Section 513 of the Federal Food, Drug and Cosmetic Act, the device classification is Class II, Performance Standards (CFR 870.1330). | | Predicate Devices: | BSC Transend EX Steerable Guidewire BSC Preceder Guidewire Terumo Corporation’s Glidewire Gold Guidewire | ## Product Description: The BSC Transend EX Platinum Guidewire with hydrophilic coating and accessories are intended for general intravascular use including the peripheral and neurovasculature. The devices will be provided sterile, and are intended for one procedure use only. Testing and evaluation included tip tensile, tip flexibility, torque strength, torque response, coating adherence, coating extraction, lubricity testing, biocompatibility and in vivo testing. ## Conclusion: Based on the Indication for Use, technological characteristics and safety and performance testing, the Transend EX Platinum Guidewire has been shown to be safe and effective for its intended use. {2} DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Ms. Mary P. LeGraw Regulatory Affairs Specialist Boston Scientific Corporation One Boston Scientific Place Natick, Massachusetts 01760-1537 JUL 1 1997 Re: K971254 Transend EX Platinum Guidewire Regulatory Class: II (two) Product Code: DQX Dated: April 2, 1997 Received: April 3, 1997 Dear Ms. LeGraw: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {3} This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for *in vitro* diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Thomas J. Callahan, Ph.D. Director Division of Cardiovascular, Respiratory, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4} Page ___ of ___ 510(k) Number (if known): New Application Device Name: Transend EX Platinum Guidewire Indications For Use: The Transend EX Platinum Guidewire is intended for general intravascular use, including the neuro and peripheral vasculature. The wire can be torqued to facilitate the selective placement of diagnostic or therapeutic catheters. This device is not intended for use in coronary arteries. A torque device (pin vise) is included with the wire to facilitate directional manipulation of the guidewire. A guidewire introducer is included with each wire to facilitate the introduction of the guidewire into catheter hubs or hemostatic valves. ![img-0.jpeg](img-0.jpeg) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) ![img-1.jpeg](img-1.jpeg) (Division Sign-Off) Division of Cardiovascular, Respiratory, and Neurological Devices 510(k) Number k971254 Prescription Use (Per 21 CFR 801.109) OK Over-The-Counter Use (Optional Format 1-2-96)
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...