SCARF THREAD-HEAD (TM) HEAD SCREW

K971070 · Landos, Inc. · HWC · Jul 9, 1997 · Orthopedic

Device Facts

Record IDK971070
Device NameSCARF THREAD-HEAD (TM) HEAD SCREW
ApplicantLandos, Inc.
Product CodeHWC · Orthopedic
Decision DateJul 9, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

This screw is to be implanted for the fixation of fractures, fusion of a joint or bone reconstruction of the mid-foot, metatarsals and phalanges of the foot. Fixation of fracture, fusion of a joint or bone reconstruction (osteotomy) of the phalanges, metacarpals and carpals of the hand.

Device Story

SCARF Thread-Head Screw is a cannulated, threaded bone fixation screw; 3.0mm diameter; 10-34mm length. Used by surgeons for orthopedic fixation/fusion in hand and foot procedures. Titanium alloy construction. Provides mechanical stabilization of bone segments to facilitate healing/fusion.

Clinical Evidence

No clinical data provided; substantial equivalence based on design and material characteristics.

Technological Characteristics

Material: Titanium alloy. Design: Cannulated screw with threaded head. Dimensions: 3.0mm diameter, 10-34mm length (2mm increments). Energy source: None (mechanical). Sterilization: Not specified.

Indications for Use

Indicated for fixation of fractures, joint fusion, or bone reconstruction (osteotomy) in the mid-foot, metatarsals, phalanges of the foot, and phalanges, metacarpals, and carpals of the hand.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0} 06/26/97 THU 15:12 FAX 219 267 7098 DePuy Clinical & Regulat 016 K971070 # SUMMARY OF SAFETY AND EFFECTIVENESS JUL - 9 1997 **MANUFACTURER IDENTIFICATION:** Medinov-AMP 27 à 31 rue Lucien Langenieux 42335 Roanne FRANCE **ESTABLISHMENT REGISTRATION NUMBER (Manufacturer):** 9681744 **SPONSOR IDENTIFICATION:** Cheryl Hastings DePuy, Inc. P.O. Box 988 700 Orthopaedic Drive Warsaw, IN 46580 **ESTABLISHMENT REGISTRATION NUMBER (Sponsor):** 1818910 **PROPRIETARY NAME:** SCARF Thread-Head Screw **PRODUCT CLASSIFICATION CODE:** 87HWC **PROPOSED REGULATORY CLASS:** Class II **DESCRIPTION:** The SCARF Thread-Head Screw is a threaded bone fixation screw that is 3.0mm in diameter and 10 to 34mm in length (in 2mm increments). It is made of titanium alloy and is cannulated with a threaded head. **INDICATIONS AND INTENDED USE:** This screw is to be implanted for the fixation of fractures, fusion of a joint or bone reconstruction of the mid-foot, metatarsals and phalanges of the foot. **PREDICATE DEVICES:** The predicate devices for this screw are the Landos SCARF Thread-Head Screw, the Zimmer Herbert-Whipple Bone Screw and the Osteomed M3 Screw. {1} DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUL - 9 1997 Ms. Cheryl Hastings DePuy, Inc. P.O. Box 988 700 Orthopaedic Drive Warsaw, Indiana 46581-0988 Re: K971070 SCARF Thread-Head™ Screw Regulatory Class: II Product Code: HWC Dated: May 30, 1997 Received: June 2, 1997 Dear Ms. Hastings: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product {2} Page 2 - Cheryl Hastings Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597, or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3} Page 1 of 1 510(k) Number (if known): K971070 Device Name: Thread-Head Screw Indications for Use: Fixation of fracture, fusion of a joint or bone reconstruction (osteotomy) of the phalanges, metacarpals and carpals of the hand. CONFIDENTIAL (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) ![img-0.jpeg](img-0.jpeg) Prescription Use ☑ (Per 21 CFR 801.109) OR Over-the-Counter Use ☐ (Optional Format 1-2-96) 000011
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...