BOBCAT DX

K970543 · Quest Enabling Designs , Ltd. · IPL · Jun 26, 1997 · Physical Medicine

Device Facts

Record IDK970543
Device NameBOBCAT DX
ApplicantQuest Enabling Designs , Ltd.
Product CodeIPL · Physical Medicine
Decision DateJun 26, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.3900
Device ClassClass 2
AttributesTherapeutic, Pediatric

Indications for Use

The highly manoeuvrable Bobcat DX enables children to determine their own activities without asking or waiting for assistance. Simultaneous development, emotional and physical, with their able bodied peer group removes the inevitable frustration which would otherwise set in. Dynamic DX control system allows a high level of control and manoeuvrability, allowing use within the home or school environment, indoors and outdoors. Elevator allows the user to adjust both sitting and standing heights enabling greater participation in activities.

Device Story

Bobcat DX is a front-wheel-drive powered wheelchair for children; features fiberglass body and elevating seat for floor-to-table height adjustment. Operated via QED-designed joystick with tactile feedback; utilizes Control Dynamics DX microprocessor control unit. Used in home, school, and outdoor environments; enables independent mobility and social participation for children up to 75kg. Output is physical movement of the chair; allows users to adjust sitting/standing heights independently. Benefits include reduced reliance on caregivers for positioning and social inclusion. Transportable via removable seat and compact design.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Front-wheel drive chassis; fiberglass body; Control Dynamics DX microprocessor control unit; joystick interface; elevating seat mechanism; weight capacity up to 75kg; modular seating options; standing frame accessory.

Indications for Use

Indicated for children up to 12 stone (75kg) in weight requiring a powered wheelchair for mobility, enabling independent movement and participation in home, school, and outdoor activities.

Regulatory Classification

Identification

A standup wheelchair is a device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position. The device incorporates an external manually controlled mechanical system that is intended to raise a paraplegic to an upright position by means of an elevating seat.

Predicate Devices

Submission Summary (Full Text)

{0} K970543 ![img-0.jpeg](img-0.jpeg) Quest Enabling Designs Ltd Ability House 242 Gosport Road Fareham Hampshire (UK) PO16 0SS Tel: +44 (0)1329 828444 Fax: +44 (0)1329 828800 # Pre-market Notification Summary ## New Device Trade Name: Quest Enabling Designs Bobcat DX, powered wheelchair. Common Name: Powered wheelchair, with adjustable elevator. Classification Name: Physical Medicine, powered wheelchair. ## Predicate Legally Marketed Device (claiming equivalence to) 510(k) Number: K942508. Trade Name: Permobil Chairman ROBO, powered wheelchair. Common Name: Powered wheelchair, with adjustable elevator. Classification: Physical Medicine. Product Code: INI. ## Description of New Device Bobcat DX is highly manoeuvrable, electrically powered wheelchair. The unit consists of a front wheel drive chassis, enclosed in an attractive colourful fibreglass body, that is powered by a Control Dynamics DX microprocessor control unit. This control unit is controlled by a QED designed joystick, which has very sensitive buttons with good tactile feedback. The Bobcat DX comes complete with an elevating seat that allows the child independently to lower themselves to the floor, or to raise themselves to table height. There are many seating options available and we also supply a standing frame. ## Intended Use of New Device The highly manoeuvrable Bobcat DX enables children to determine their own activities without asking or waiting for assistance. Simultaneous development, emotional and physical, with their able bodied peer group removes the inevitable frustration which would otherwise set in. Dynamic DX control system allows a high level of control and manoeuvrability, allowing use within the home or school environment, indoors and outdoors. Elevator allows the user to adjust both sitting and standing heights enabling greater participation in activities. {1} DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Mr. Naheed Akhtar Quest Enabling Designs Limited Ability House, 242 Gosport Road Fareham, Hampshire PO16 OSS JUN 26 1997 Re: K970543 Trade Name: Quest Enabling Designs Bobcat DX Regulatory Class: II Product Code: IPL Dated: April 7, 1997 Received: April 14, 1997 Dear Mr. Akhtar: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will {2} Page 2 - Mr. Naheed Akhtar verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, ![img-1.jpeg](img-1.jpeg) Enclosure {3} Statements for Indications of Use. Bobcat DX is highly manoeuvrable, electrically powered wheelchair. The unit consists of a front wheel drive chassis, enclosed in an attractive colourful fibreglass body, that is powered by a Control Dynamics DX microprocessor control unit. This control unit is controlled by a QED designed joystick, which has very sensitive buttons with good tactile feedback. The Bobcat DX comes complete with an elevating seat that allows the child independently to lower themselves to the floor, or to raise themselves to table height. There are many seating options available and we also supply a standing frame. The child can easily adjust both sitting and standing heights, enabling participation at a table or bar for meals. Exclusion from normal eating areas and the necessity to have cumbersome trays or special furniture become things of the past. Playing on the floor and outdoors encourages independence for the child, leaving parents and carers free to continue with family socialising and household tasks, knowing that their child can move freely at will. With most activities pressure to assist is reduced merely to supervising normal play and development. The highly manoeuvrable Bobcat DX enables children to determine their own activities without asking or waiting for assistance. Simultaneous development, emotional and physical, with their able bodied peer group removes the inevitable frustration which would otherwise set in. Transporting the Bobcat DX presents no difficulty with the easily removable seat, remote drive panel and compact size of the unit. Benefits include: - QED offers a wide range of seating options. - Dynamic DX control system enables the Bobcat DX to be used successfully within the school, home or outdoor. - Three dimensional movement reduces the need for carer participation in many activities. - Easy 'break-down' for transport in the back of estate car. - Accessories available including trays, lights and indicators and ramps. - Suitable for users up to 12 stone (75kg) in weight. Over-the-Counter Use ☑ (Division Sign-Off) M. M. (MW) Division of General Restorative Devices 510(k) Number K970543 10-1
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...