FIXATION PIN OR ROD

K970036 · United States Surgical, A Division of Tyco Healthc · HTY · Mar 25, 1997 · Orthopedic

Device Facts

Record IDK970036
Device NameFIXATION PIN OR ROD
ApplicantUnited States Surgical, A Division of Tyco Healthc
Product CodeHTY · Orthopedic
Decision DateMar 25, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

Both the Surgical Dynamics™ Bone Pin** and the Poly-Medics Lactosorb® Bone Pin (K953194) are intended for fixation of small bone fragments in non-load bones with appropriate immobilization.

Device Story

Resorbable fixation pin; used for small bone fragment stabilization in non-load bearing applications; requires external immobilization; supplied in various sizes; intended for surgical use.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Resorbable fixation pin; biosafe material composition; various sizes available; supplied without K-wires.

Indications for Use

Indicated for fixation of small bone fragments in non-load bearing bones requiring immobilization.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0} United States Surgical Corporation 510(k) Premarket Notification Surgical Dynamics™ Bone Pin** K970036 MAR 25 1997 # 510(k) SUMMARY OF INFORMATION: **SUBMITTER:** United States Surgical Corporation 150 Glover Avenue Norwalk, CT 06856 (203) 845-1000 **CONTACT PERSON:** Melissa Mazzoni **DATE PREPARED:** December 31, 1996 **CLASSIFICATION NAME:** Pin, Fixation, Smooth or threaded metallic bone fixation fastener **COMMON NAME:** Fixation Pin or Rod **PROPRIETARY NAME:** Trademark name not yet determined. **DEVICE DESCRIPTION:** The Surgical Dynamics™ Bone Pin** is a resorbable fixation pin intended for fixation of small bone fragments in non-load bones with appropriate immobilization. It will be available in a range of sizes and will be supplied without attached K-wires. **PREDICATE DEVICE:** Poly-Medics Lactosorb® Bone Pin (K953194) **INTENDED USE:** Both the Surgical Dynamics™ Bone Pin** and the Poly-Medics Lactosorb® Bone Pin (K953194) are intended for fixation of small bone fragments in non-load bones with appropriate immobilization. **MATERIALS:** Both the Surgical Dynamics™ Bone Pin** and the Poly-Medics Lactosorb® Bone Pin (K953194) are comprised of biosafe materials. ** Trademark name not yet determined. Page 11
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...