NATURAL-HIP SYSTEM COCR STEM
Device Facts
| Record ID | K964357 |
|---|---|
| Device Name | NATURAL-HIP SYSTEM COCR STEM |
| Applicant | Intermedics Orthopedics |
| Product Code | LZO · Orthopedic |
| Decision Date | Jan 27, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3353 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Natural-Hip System CoCr Stem is intended to replace the anatomy of the femur in cases of total hip or hemi-hip replacement. The Natural-Hip System CoCr Stem is intended for cemented application only. The general indications associated with the use of Natural-Hip System CoCr Stem in total hip arthroplasty include: 1. Patient conditions of non-inflammatory degenerative joint disease (NIDJD), e.g., avascular necrosis, osteoarthritis and inflammatory joint disease (IJD), e.g., rheumatoid arthritis. 2. Those patients with failed previous surgery where pain, deformity or dysfunction persists. 3. Revision of previously failed arthroplasty. Total hip replacements may be considered for younger patients if any unequivocal indication outweighs the risks associated with the age of the patient, and modified demands regarding activity and hip joint loading are assured. This includes severely crippled patients with multiple joint involvement for whom an immediate need of hip mobility leads to an expectation of significant improvement in the quality of their lives.
Device Story
Femoral component of total hip prosthesis; straight stem with proximal wedge design; available in collared/collarless versions. Proximal third grit-blasted with normalization steps to enhance cement bonding. Features Sulzer 12/14 neck trunnion for modular head attachment; distal hole for centralizer; proximal PMMA centralizers for cement mantle uniformity. Used in cemented total or hemi-hip arthroplasty. Implanted by orthopedic surgeons in clinical settings. Provides structural replacement of femoral anatomy; restores joint mobility; reduces pain associated with degenerative or inflammatory joint disease.
Clinical Evidence
No clinical data provided; substantial equivalence based on design, material, and intended use characteristics compared to predicate devices.
Technological Characteristics
Material: Cobalt-Chromium (CoCr) alloy. Design: Straight stem, proximal wedge, grit-blasted surface, normalization steps. Interface: Sulzer 12/14 neck trunnion. Fixation: Cemented application with proximal and distal PMMA centralizers. Single-use.
Indications for Use
Indicated for patients requiring total or hemi-hip replacement due to non-inflammatory degenerative joint disease (e.g., avascular necrosis, osteoarthritis), inflammatory joint disease (e.g., rheumatoid arthritis), failed previous surgery, or revision of failed arthroplasty. Intended for cemented application only.
Regulatory Classification
Identification
A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A12 03 ) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement.
Predicate Devices
- Natural-Hip System - DRG Hip Stem (Intermedics Orthopedics, Inc.)
- Premier Hip Stem (Intermedics Orthopedics, Inc.)
- ODC Hip Stem (Osteonics Corporation)
- Perfecta IMC Stem (Orthomet Inc.)
Reference Devices
- IOI metallic femoral bearing heads (K905781, K913060)
- IOI Biolox Bearing Heads (K923734, K942330)
- Zirconia Bearing Heads (K944209)
- IOI bipolar components (K833404, K873815)
- IOI unipolar components (K833403, K934159)
- IOI acetabular components (K850793, K920955, K933203, K942406, K941617, K955033, K955739)