← Product Code [MBI](/productcode/MBI) · K964324

# MULTITAK SS SUTURE SYSTEM (K964324)

_Bonutti Research · MBI · Jan 10, 1997 · Orthopedic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K964324

## Device Facts

- **Applicant:** Bonutti Research
- **Product Code:** [MBI](/productcode/MBI.md)
- **Decision Date:** Jan 10, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3040
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The devices are intended for soft tissue to bone suture fixation for the following indications: Shoulder - Rotator cuff tear repairs - Biceps tenodesis Foot and Ankle - Lateral instability repairs/reconstructions Elbow, Wrist and Hand - Ulnar or radial collateral ligament reconstructions - Tennis elbow repair - Biceps tendon reattachment Knee - Extra-capsular repairs: - Medial collateral ligament - Lateral collateral ligament

## Device Story

Tubular soft tissue anchor; preassembled with USP size 2-0 to 2 braided polyester suture. Introduction device delivers anchor into predrilled bone hole; sutures secure soft tissue to bone. Used by surgeons in clinical settings for orthopedic repairs. Facilitates fixation of ligaments and tendons to bone; enables tissue reattachment.

## Clinical Evidence

No clinical data; bench testing only.

## Technological Characteristics

Tubular anchor; braided polyester suture (USP 2-0 to 2); metallic bone fixation fastener per 21 CFR 888.3040. Includes introduction device for delivery into predrilled bone holes.

## Regulatory Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- Multitak SS Suture System ([K934183](/device/K934183.md))
- GII Anchor System ([K953877](/device/K953877.md))
- Mini QuickAnchor ([K930892](/device/K930892.md))
- Mini QuickAnchor ([K904436](/device/K904436.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

NUTTI RESEARCH, INC.
1&lt;964324

# Summary of Safety and Effectiveness
## Multitak Suture System™

- **Submitted by**
Bonutti Research
1303 Evergreen Ave.
Effingham, IL 62401

- **Prepared by**
Lynnette Whitaker
Director
Regulatory Affairs/Quality Assurance

- **Date**
October 28, 1996

- **Trade Name**
Multitak Suture System

- **Common Name**
Soft Tissue Anchor

- **Classification Name**
21 CFR 888.3040, Smooth or Threaded Metallic Bone Fixation Fastener

- **Predicate Devices**
- Multitak SS Suture System, manufactured by Bonutti Research, K934183.
- GII Anchor System, manufactured by Mitek Surgical Products, Inc., K953877.
- Mini QuickAnchor, manufactured by Mitek Surgical Products, Inc., K930892 and K904436.

JAN 10 1997

{1}

17

- Device Description

The anchor is tubular in shape and is preassembled threaded with USP size 2-0 through 2 braided polyester suture. An Introduction Device holds the anchor and delivers it into the bone through a predrilled hole. The sutures can then be used to secure the soft tissue to the bone.

- Intended Use

The devices are intended for soft tissue to bone suture fixation for the following indications:

Shoulder
- Rotator cuff tear repairs
- Biceps tenodesis

Foot and Ankle
- Lateral instability repairs/reconstructions

Elbow, Wrist and Hand
- Ulnar or radial collateral ligament reconstructions
- Tennis elbow repair
- Biceps tendon reattachment

Knee
- Extra-capsular repairs:
- Medial collateral ligament
- Lateral collateral ligament

- Performance Data

The nature of device changes do not necessitate performance data testing.

---

**Source:** [https://fda-staging.innolitics.com/device/K964324](https://fda-staging.innolitics.com/device/K964324)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).