MORRISON MEDICAL STRETCHER/COT AND BACKBOARD RESTRAINTS

K963399 · Morrison Medical Products · FMQ · Nov 6, 1996 · General Hospital

Device Facts

Record IDK963399
Device NameMORRISON MEDICAL STRETCHER/COT AND BACKBOARD RESTRAINTS
ApplicantMorrison Medical Products
Product CodeFMQ · General Hospital
Decision DateNov 6, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.6760
Device ClassClass 1

Indications for Use

Morrison Medical Stretcher/Cot and Backboard Restraints are intended to help secure a patient’s body to a stretcher, cot or backboard.

Device Story

Restraints secure patient body to stretcher, cot, or backboard; used by qualified/trained personnel in emergency/transport settings. Device consists of webbing (nylon, polypropylene, or vinyl-coated polyester), buckles/closures (metal/plastic push-button, cam, roller, or D-ring), and end styles (Loop-Lok, speed clips). One-piece straps wrap around patient and frame; two-piece straps connect to frame on both sides. Buckles secure straps; end styles attach to stretcher/backboard hardware. No electronic components or software.

Clinical Evidence

No clinical data. Biocompatibility assessment based on material history and lack of reported skin irritation.

Technological Characteristics

Webbing materials: nylon, polypropylene, vinyl-coated polyester. Buckles: metal/plastic push-button, cam, roller, D-ring. End styles: Loop-Lok, swivel/non-swivel speed clips. Mechanical restraint system; no energy source, connectivity, or software.

Indications for Use

Indicated for securing patients to stretchers, cots, or backboards by qualified and trained personnel.

Regulatory Classification

Identification

A protective restraint is a device, including but not limited to a wristlet, anklet, vest, mitt, straight jacket, body/limb holder, or other type of strap, that is intended for medical purposes and that limits the patient's movements to the extent necessary for treatment, examination, or protection of the patient or others.

Predicate Devices

Submission Summary (Full Text)

{0} MORRISON MEDICAL PRODUCTS NOV - 6 1996 K 963399 # Morrison Medical Products ## Stretcher/Cot and Backboard Restraints # Safety and Effectiveness Summary ## 1. Submitter's name, Address and Contact Person | Submitter | Contact Person | | --- | --- | | Morrison Medical Products 610 W. Town Street Columbus, OH 43215-4446 | Joseph S. Tokarz; Manager, Regulatory Affairs Hollister Incorporated 2000 Hollister Drive Libertyville, IL 60048 Ph: (847)680-2849, Fax: (847)918-3860 | Date Summary Prepared - August 27, 1996 ## 2. Name of Device: Morrison Medical Stretcher/Cot and Backboard Restraints ## 3. Name of Predicate Device(s) Morrison Medical Stretcher/Cot and Backboard Restraints ## 4. Description of Device The Morrison Medical Stretcher/Cot and Backboard Restraints are intended to be used by qualified and properly trained personnel to help secure a patient’s body to a stretcher, cot or backboard. The Morrison Medical Stretcher/Cot and Backboard restraints connect to or wrap around a stretcher, cot or backboard. The restraints are constructed by combining various webbing, buckles/closures and end styles. The webbing is available in nylon, polypropylene and vinyl coated polyester materials. The webbing that is used is dependent on user preference. The Morrison Medical Stretcher/Cot and Backboard Restraints are available as a reusable or disposable (series 139x) restraint. The restraint is available in either a one-piece length or two-piece lengths depending on user preference. The one-piece restraint wraps around a patient and the stretcher, cot or backboard and is secured with a buckle. The two-piece restraint is connected to the frame on both sides of the stretcher, cot or backboard with an end-style (end-style description below) and is secured together with a buckle/closure. (See chart below for a detailed description of the one- and two-piece length presentation) The buckles are available in six different styles (see chart below) depending once again on user preference. On the end of the two-piece restraint webbing is an end style. The Page 23 610 WEST TOWN STREET COLUMBUS, OH 43215 FAX 614•469•96•96 614-461-4400 {1} M MORRISON MEDICAL PRODUCTS # Morrison Medical Products ## Stretcher/Cot and Backboard Restraints end style is the component of the restraint that connects to the stretcher, cot or backboard. There are four different end styles available (see chart below), depending on the whether the restraint will be used with a stretcher, cot or backboard and depending on user preference. One-Piece and Two-Piece Webbing and Strap Length Presentation: | Length/No. of Straps | Description | | --- | --- | | Five foot section; two piece strap | The two sections of webbing are connected to each other by the preferred buckle to form a five foot section. At the end of each section is the preferred end style that connects to the stretcher/cot or backboard frame. | | Seven foot section; two piece strap | The two sections of webbing are connected to each other by the preferred buckle to form a seven foot section. At the end of each section is the preferred end style that connects to the stretcher/cot or backboard frame. | | Seven foot section; one piece strap | The restraint is constructed with the preferred webbing and buckle of choice. One component of the buckle is secured to each end of the seven foot strap. | | Nine foot section; one piece strap | The restraint is constructed with the preferred webbing and buckle of choice. One component of the buckle is secured to each end of the nine foot strap. | ## Restraint Buckles/Closures The buckle/closure that connects the webbing material is intended to close together to secure the patient while he/she is lying on the stretcher/cot or backboard. The style of buckle/closure that is used is based on user preference. All the buckles/closures perform the same basic function, closing together to secure the patient onto the stretcher/cot or backboard. On the following page is a chart that provides the name and description of each buckle/closure style. 610 WEST TOWN STREET COLUMBUS, OH 43215 FAX 614•469•96•96 614-461-4400 {2} M MORRISON MEDICAL PRODUCTS # Morrison Medical Products ## Stretcher/Cot and Backboard Restraints | Name of buckle/closure | Description | | --- | --- | | Metal Push Button (auto) | Similar to an auto seat belt. Push ends together to secure; push button to release. | | Plastic side release | Polypropylene quick release closure. Push ends together to secure; squeeze sides together to release | | Metal Cam (friction) Plastic Cam (friction) | Metal Buckle. Thread webbing through back of buckle and press buckle lever down to secure; pull buckle lever up and unthread webbing to release | | Metal Roller Buckle (friction) | Metal Roller Buckle. Thread webbing through buckle and move sliding bar to roller bar to secure; move sliding bar off roller bar and unthread webbing to release | | Metal Double D-Ring | 2" Metal Double D-Rings. Thread webbing through Double D-Ring to secure; unthread webbing to release | ## End Styles The end style is the component of the restraint that connects to the stretcher/cot or backboard. There are four different end styles available depending on whether the restraints will be used with a stretcher/cot or backboard and depending on user preference. Below is a chart which shows the name and description of each end style. | Name | Description | | --- | --- | | Loop-Lok™ End | Loop-Lok ends can be used with stretchers/cots and backboards. Webbing wraps around stretcher frame or backboard hand hold and through end of webbing where loop is sewn. Unthread loop to release | | Non-Swivel Speed Clip | Non-Swivel Speed Clips are to be used with specially designed backboards containing speed clip pins only. Clips onto backboard pin and locks shut. Does not swivel. Push lock in to release. | | Metal Swivel Speed Clip Plastic Swivel Speed Clip | Swivel Speed Clips are to be used with specially designed backboards containing speed clip pins only. Clips onto backboard pin and locks shut. Push lock in to release. | 610 WEST TOWN STREET COLUMBUS, OH 43215 FAX 614-469-96-96 614-461-4400 {3} MORRISON MEDICAL PRODUCTS # Morrison Medical Products ## Stretcher/Cot and Backboard Restraints ### 5. Statement of Intended Use Morrison Medical Stretcher/Cot and Backboard Restraints are intended to help secure a patient’s body to a stretcher, cot or backboard. ### 6. Statement of Technological Characteristics of the Device The Morrison Medical Stretcher/Cot and Backboard restraints connect to or wrap around a stretcher, cot or backboard. The restraints are constructed by combining various types of webbing materials, buckles/closures and end styles. The subject devices are identical in intended use, design, materials, manufacturing process, physical and mechanical specifications and issues of safety and effectiveness to the devices prior to the submission of this notification. The only difference is that the product labeling has been revised to comply with the Agency’s labeling requirements set forth in the draft “Guidance on the Content of Premarket Notification [510(k)] Submissions for Protective Restraints” dated December 1995. ### 7. Biocompatibility Assessment The subject devices are identical in component materials to the predicate devices. Morrison Medical Products is not aware of any reports or complaints of skin irritation associated with the materials used in these devices. A biocompatibility review of these materials indicated little potential to evoke an adverse reaction. ### 8. Conclusion Based upon the information presented above it is concluded that the proposed Morrison Medical Stretcher/Cot and Backboard restraints are safe and effective for their intended use and are substantially equivalent to the predicate devices. Page 26 610 WEST TOWN STREET COLUMBUS, OH 43215 FAX 614•469•96•96 614-461-4400
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...