← Product Code [GEX](/productcode/GEX) · K963340

# MEDLITE ND:YAG LASER SYSTEM: NEW DYE ACCESSORY HANDPIECE (K963340)

_Continuum Biomedical, Inc. · GEX · May 12, 1997 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K963340

## Device Facts

- **Applicant:** Continuum Biomedical, Inc.
- **Product Code:** [GEX](/productcode/GEX.md)
- **Decision Date:** May 12, 1997
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4810
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

For use in dermatology for the removal of tattoos and the treatment of vascular and pigmented lesions.

## Device Story

Dye Accessory Handpiece for Medlite Nd:YAG Laser System; consists of handpiece with optical cavity/focusing optics, plastic dye module, power meter, and safety goggles. Device modifies laser output wavelengths to increase efficiency for tattoo removal and treatment of vascular/pigmented lesions. Used in clinical dermatology settings by physicians. Output allows targeted laser energy delivery to skin lesions; enhances clinical efficacy for dermatological procedures.

## Clinical Evidence

No clinical data provided.

## Technological Characteristics

Dye accessory handpiece; includes optical cavity, focusing optics, plastic dye module, and power meter. Modifies Nd:YAG laser output wavelengths. Class II surgical laser system (21 CFR 878.48).

## Regulatory Identification

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

## Predicate Devices

- Medlite™ Nd:YAG Laser System ([K955131](/device/K955131.md))
- Medlite™ Nd:YAG Laser System ([K952636](/device/K952636.md))
- Medlite™ Nd:YAG Laser System ([K940607](/device/K940607.md))
- Medlite™ Nd:YAG Laser System ([K940636](/device/K940636.md))
- Medlite™ Nd:YAG Laser System ([K922935](/device/K922935.md))
- Medlite™ Nd:YAG Laser System ([K922577](/device/K922577.md))
- Medlite™ Nd:YAG Laser System ([K915497](/device/K915497.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

510(K) PREMARKET NOTIFICATION
Medlite Nd:YAG Laser System
Continuum Biomedical, Inc.
August 23, 1996
MAY 12 1997
K 963340

# 510(k) Summary

|  Submitter: | Continuum Biomedical, Inc.
2456 Armstrong Street
Livermore, CA 94550-7617
Phone: 510-606-3750
Fax: 510-371-1015  |
| --- | --- |
|  Contact: | Robert S. Anderson, Ph. D.
President  |
|  Date Summary Prepared: | August 23, 1996  |
|  Device Trade Name: | Medlite™ Nd:YAG Laser System: New Dye Accessory Handpiece  |
|  Common Name: | Dermatology laser system  |
|  Classification Name: | Instrument, surgical, powered, laser
79-GEX
21 CFR 878.48  |
|  Equivalent Device: | Medlite™ Nd:YAG Laser System (K955131, K952636, K940607, K940636, K922935, K922577, K915497)  |
|  Device Description: | The new Dye Accessory Handpiece for the Medlite™ Nd:YAG Laser System is consists of four primary parts: the handpiece which contains a short optical cavity and focusing optics, the plastic dye module, the commercial power meter and appropriate laser safety goggles.  |
|  Intended Use: | For use in dermatology for the removal of tattoos and the treatment of vascular and pigmented lesions.  |
|  Comparison: | The new Dye Accessory Handpiece allows the Medlite™ Nd:YAG Laser System to deliver slightly altered wavelengths for increased efficiency in treating tattoos, vascular and pigmented lesions.  |
|  Nonclinical Performance Data: | none  |
|  Clinical Performance Data: | none  |
|  Conclusion: | The Medlite™ Nd:YAG Laser System is substantially equivalent to other existing surgical laser systems in commercial distribution for the treatment of tattoos, vascular and pigmented lesions.  |
|  Additional Information: | None requested at this time.  |

c:\conbiol\medlite\510kcolor.doc:13

---

**Source:** [https://fda-staging.innolitics.com/device/K963340](https://fda-staging.innolitics.com/device/K963340)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
