STERI-OSS TEMPORARY IMPLANT CEMENT

K963078 · Steri-Oss, Inc. · EMA · Sep 10, 1996 · Dental

Device Facts

Record IDK963078
Device NameSTERI-OSS TEMPORARY IMPLANT CEMENT
ApplicantSteri-Oss, Inc.
Product CodeEMA · Dental
Decision DateSep 10, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3275
Device ClassClass 2

Indications for Use

The cement is indicated for use in the cementing (luting) of a implant prosthesis.

Device Story

Steri-Oss Temporary Implant Cement; two-part polyalkylene resin paste; self-curing upon mixing; used by dentists for retention of implant prostheses; provides temporary fixation.

Clinical Evidence

No clinical data; bench testing only.

Technological Characteristics

Two-part polyalkylene resin paste; self-curing; dental cement.

Indications for Use

Indicated for cementing (luting) of implant prostheses in dental patients.

Regulatory Classification

Identification

Zinc oxide-eugenol is a device composed of zinc oxide-eugenol intended to serve as a temporary tooth filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or bridges, or to be applied to a tooth to protect the tooth pulp. Dental cement other than zinc oxide-eugenol is a device composed of various materials other than zinc oxide-eugenol intended to serve as a temporary tooth filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or bridges, or to be applied to a tooth to protect the tooth pulp.

Predicate Devices

Submission Summary (Full Text)

{0} SEP 10 1996 K963078 Steri-Oss Temporary Implant Cement Orginal 510(k) Submission ## Section 6 ## 510(k) Summary ### Manufacturer Information: Submitter's Name: Steri-Oss Inc. Address: 22895 Eastpark Drive Yorba Linda, CA 92887 U.S.A. Contact's Name: Don Kennard Regulatory Affairs Phone: 714-282-4811 Fax: 714-988-9236 Date Prepared: August 1996 ### Devices Names: Common Name: Dental Cement Trade Name: Steri-Oss Temporary Implant Cement Classification Name: Dental Cement ### Predicate Device: Substantial equivalence is claimed to Septodont’s Resiment resin cement. ### Device Description: How the device functions: The Steri-Oss Temporary Implant Cement serves as a cement for retention of implant prosthesis. The cement is a two part paste which is self cured on mixing and application. The product is provided in two 10 gram containers of polyalkylene material. 14 {1} 15 # Steri-Oss Temporary Implant Cement ## Orginal 510(k) Submission ### Intended Use: The cement is indicated for use in the cementing (luting) of a implant prosthesis. ### Comparison to Predicate The following table provides a comparison of the technological characteristic of the Steri-Oss Temporary Implant Cement to the predicate. | Item | Predicate | Steri-Oss | | --- | --- | --- | | Curing | Self Cured | Self Cured | | System | Two part system | Two part system | | Cement base | Resin filled | Resin filled | ### Performance Data Not applicable, 510(k) requests a indication.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...