# MICRO SPIROMETER (K963035)

_Micro Direct, Inc. · BZG · Nov 1, 1996 · Anesthesiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K963035

## Device Facts

- **Applicant:** Micro Direct, Inc.
- **Product Code:** [BZG](/productcode/BZG.md)
- **Decision Date:** Nov 1, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 868.1840
- **Device Class:** Class 2
- **Review Panel:** Anesthesiology

## Indications for Use

The intended device takes spirometer readings of a patient during exhalation. The output readings are FEV1 and FVC.

## Device Story

Hand-held portable electronic spirometer; measures FEV1 and FVC during patient exhalation. Uses flow-sensing turbine transducer; LCD display for output. Operated by clinicians in home or hospital settings. Device provides lung function measurements to assist clinical evaluation.

## Clinical Evidence

No clinical data; bench testing only.

## Technological Characteristics

Hand-held electronic spirometer; flow-sensing turbine transducer; LCD display. Flow range 0-12 lps BTPS; volume range 0-9.99 liters. Accuracy +/- 3%. Utilizes paper mouthpiece; transducer requires cleaning after use.

## Regulatory Identification

A diagnostic spirometer is a device used in pulmonary function testing to measure the volume of gas moving in or out of a patient's lungs.

## Predicate Devices

- Spirometrics Model 2600 Micro Spirometer ([K901057](/device/K901057.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K963035

Micro

Direct

NOV - 1 1996

# Non-Confidential Summary of Safety and Effectiveness

August 1, 1996

page 1 of 2

Micro Direct, Inc.
840 Pownal Rd.
Auburn, ME 04210
Tel - (207) 786-7808
Fax - (207) 786-7280

Official contact: David R. Staszak, President

Proprietary or Trade Name: Micro Spirometer

Common/Usual Name: Diagnostic Spirometer

Classification Name: 73 BZG - Diagnostic Spirometer

Intended device: Diagnostic spirometer

Predicate devices: Spirometrics Model 2600 Micro Spirometer - K901057

Device description: A hand-held portable electronic spirometer measuring FEV1 and FVC.

## Indicated use:

The intended device takes spirometer readings of a patient during exhalation. The output readings are FEV1 and FVC.

## Targeted population:

Patients requiring lung function evaluations.

## Environment of use:

Places where a qualified clinician desires to take these lung measurements - FEV1 and FVC.

## Comparison to predicate devices:

|  Attribute | Intended device | Spirometrics Model 2600  |
| --- | --- | --- |
|  Use |  |   |
|  Intended as a spirometer | Yes | Yes  |
|  Intended to measure lung function FEV1 and FVC | Yes | Yes  |

page 3 of 29

Micro Direct, Inc. • 840 Pownal Road • P. O. Box 239 • Auburn, ME 04212-0239

{1}

Non-Confidential Summary of Safety and Effectiveness
August 1, 1996
page 2 of 2

Comparison to predicate devices: (continued)

|  Attribute | Intended device | Spirometrics Model 2600  |
| --- | --- | --- |
|  Use (continued) |  |   |
|  Indicated for measuring patients lung function | Yes | Yes  |
|  Indicated for use by a clinician in environments such as the home or hospital | Yes | Yes  |
|  Manufactured by Micro Medical | Yes | Yes  |
|  Exact same unit as supplied to and marketed by Spirometrics and approved under K901057 | Yes | --  |
|  Design |  |   |
|  Transducer - flow sensing turbine | Yes | Yes  |
|  No output | Yes | Yes  |
|  Flow range Ips BTPS 0-12 | Yes | Yes  |
|  Volume range liters 0-9.99 | Yes | Yes  |
|  Measures - FVC - FEV1 | Yes | Yes  |
|  Accuracy + / - 3 | Yes | Yes  |
|  Display LCD | Yes | Yes  |
|  Transducer cleaned after use | Yes | Yes  |
|  Utilizes paper mouthpiece | Yes | Yes  |
|  Materials |  |   |
|  Same materials as K901057 | Yes | Yes  |
|  Performance Testing |  |   |
|  None applicable | Yes | Yes  |

## Differences

There is no difference between the intended device and the listed predicate device.

page 4 of 29

---

**Source:** [https://fda-staging.innolitics.com/device/K963035](https://fda-staging.innolitics.com/device/K963035)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).