COMPRESSION SCREW

K962779 · Orthopaedic Biosystems, Ltd. · HWC · Aug 23, 1996 · Orthopedic

Device Facts

Record IDK962779
Device NameCOMPRESSION SCREW
ApplicantOrthopaedic Biosystems, Ltd.
Product CodeHWC · Orthopedic
Decision DateAug 23, 1996
DecisionSN
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The proposed device, the small bone screw claims substantial equivalence to a currently marketed device, the Synthes mini-fragment bone screw. The Synthes screws and the proposed device are both available in Titanium and Stainless Steel. Both function as internal fixation for bones and have no significant design differences.

Device Story

Small bone screw; internal fixation for bones; titanium or stainless steel construction; used by orthopedic surgeons in clinical settings; provides mechanical stabilization of bone fragments; facilitates healing.

Clinical Evidence

Bench testing only; substantial equivalence based on design and material comparison to predicate.

Technological Characteristics

Materials: Titanium and stainless steel. Form factor: Small bone screw. Function: Internal bone fixation. Mechanical device; no software or energy source.

Indications for Use

Indicated for internal fixation of small bones.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0} AUG 23 1996 K962779 OBL ORTHOPAEDIC BIOSYSTEMS LTD., INC. Small Bone Screw 510(k)Summary Safety and Effectiveness The proposed device, the small bone screw claims substantial equivalence to a currently marketed device, the Synthes mini-fragment bone screw. The Synthes screws and the proposed device are both available in Titanium and Stainless Steel. Both function as internal fixation for bones and have no significant design differences. 7320 E. BUTHERUS • SUITE 206 • SCOTTSDALE • ARIZONA • 85260 (602) 596-4066 • (800) 487-9128 • FAX (602) 596-2180
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...