MEDOFF SLIDING PLATE (PROPOSED NAME)

K962251 · Wrightmedicaltechnologyinc · KTT · Jan 22, 1997 · Orthopedic

Device Facts

Record IDK962251
Device NameMEDOFF SLIDING PLATE (PROPOSED NAME)
ApplicantWrightmedicaltechnologyinc
Product CodeKTT · Orthopedic
Decision DateJan 22, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3030
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The sterile Medoff Sliding Plate System includes lag screws, compression screws, locking set screws, and bone plates consisting of a compression slide and a barreled side plate. The indications for the sterile Medoff Sliding Plate System vary depending on the configuration of the bone plate. Fracture configurations which lend themselves to the general principle of axial compression should be those that are selected for use with this device. The use of the 4-hole or the 6-hole plating system depends upon surgeon preference and the selection is more related to the size of the surgical exposure and how far down the shaft the fracture extends. Specific indications for the 135 degree 4-hole standard plate design or 6-hole standard plate design include the following fracture configurations: Basicervical fractures of the femur. Intertrochanteric fractures of the femur. Unstable intertrochanteric fractures of the femur. High subtrochanteric fractures of the femur just distal to the level of the lesser trochanter. Specific indications for the supracondylar plate design include the following fracture configurations: Low transverse or short oblique supracondylar fractures of the distal femur. T condylar fractures of the femur that can be converted to low transverse or short oblique supracondylar fractures by rigid fixation of condylar fragments with screws.

Device Story

Metallic bone fixation system; includes lag screws, compression screws, locking set screws, and bone plates with compression slide and barreled side plate. Used by surgeons in clinical settings for internal fixation of femoral fractures. Device applies principle of axial compression to stabilize fracture sites. Surgeon selects plate configuration (4-hole or 6-hole) based on fracture extent and surgical exposure. Provides rigid fixation to facilitate bone healing.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Manufactured from stainless steel. System comprises lag screws, compression screws, locking set screws, and bone plates with compression slide and barreled side plate. Mechanical fixation device.

Indications for Use

Indicated for patients with femoral fractures requiring axial compression, specifically basicervical, intertrochanteric, unstable intertrochanteric, and high subtrochanteric femoral fractures (standard plate designs), or low transverse, short oblique, and T-condylar supracondylar fractures of the distal femur (supracondylar plate design).

Regulatory Classification

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0} JAN 22 1997 K962251 Contact Person: Judy English Date Prepared: January 3, 1997 # 510(k) Summary Trade Name: Medoff Sliding Plate System (Sterile) Common Name: Metallic bone fixation device Product Classification: II Predicate Devices: Axial Compression Screw and Hawaiian Supracondylar Plate This 510(k) summary is being submitted in accordance with the requirements of 21 CFR 807.92. ## Description/Indications for Use The sterile Medoff Sliding Plate System includes lag screws, compression screws, locking set screws, and bone plates consisting of a compression slide and a barreled side plate. The indications for the sterile Medoff Sliding Plate System vary depending on the configuration of the bone plate. Fracture configurations which lend themselves to the general principle of axial compression should be those that are selected for use with this device. The use of the 4-hole or the 6-hole plating system depends upon surgeon preference and the selection is more related to the size of the surgical exposure and how far down the shaft the fracture extends. ## Specific indications for the 135 degree 4-hole standard plate design or 6-hole standard plate design include the following fracture configurations: - Basicervical fractures of the femur. - Intertrochanteric fractures of the femur. - Unstable intertrochanteric fractures of the femur. - High subtrochanteric fractures of the femur just distal to the level of the lesser trochanter. ## Specific indications for the supracondylar plate design include the following fracture configurations: - Low transverse or short oblique supracondylar fractures of the distal femur. - T condylar fractures of the femur that can be converted to low transverse or short oblique supracondylar fractures by rigid fixation of condylar fragments with screws. ## Material The sterile Medoff Sliding Plate System is manufactured from stainless steel. 000011
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...